RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

        Oliveira, Matheus L.,Tosoni, Guilherme M.,Lindsey, David H.,Mendoza, Kristopher,Tetradis, Sotirios,Mallya, Sanjay M. Korean Academy of Oral and Maxillofacial Radiology 2014 Imaging Science in Dentistry Vol.44 No.4

        Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

      • KCI등재

        Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

        Matheus L. Oliveira,Guilherme M. Tosoni,David H. Lindsey,Kristopher Mendoza,Sotirios Tetradis,Sanjay M. Mallya 대한영상치의학회 2014 Imaging Science in Dentistry Vol.44 No.4

        Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

      • KCI등재

        Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols

        Barros-Costa Matheus,Nascimento Eduarda Helena Leandro,Correia-Dantas Iago Filipe,Oliveira Matheus L.,Freitas Deborah Queiroz 대한영상치의학회 2024 Imaging Science in Dentistry Vol.54 No.1

        Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR (P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.

      • KCI등재

        A novel method of objectively detecting tooth ankylosis using cone-beam computed tomography: A laboratory study

        Martins Luciano Augusto Cano,Brasil Danieli Moura,Freitas Deborah Queiroz,Oliveira Matheus L 대한영상치의학회 2023 Imaging Science in Dentistry Vol.53 No.1

        Purpose: The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods: Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test (α = 0.05). Results: The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions (P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non- ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas (P>0.05). Conclusion: The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.

      • SCOPUSKCI등재

        Structural complexity of the craniofacial trabecular bone in multiple myeloma assessed by fractal analysis

        Michels, Mariane,Morais-Faria, Karina,Rivera, Cesar,Brandao, Thais Bianca,Santos-Silva, Alan Roger,Oliveira, Matheus L Korean Academy of Oral and Maxillofacial Radiology 2021 Imaging Science in Dentistry Vol.51 No.-

        Purpose: This study aimed to evaluate the structural complexity of craniofacial trabecular bone in multiple myeloma by fractal analysis of panoramic and lateral skull radiography, and to compare the fractal dimension values of healthy patients (HPs), pre-treatment patients (PTPs), and patients during bisphosphonate treatment (DTPs). Materials and Methods: Pairs of digital panoramic and lateral skull radiographs of 84 PTPs and 72 DTPs were selected. After application of exclusion criteria, 43 panoramic and 84 lateral skull radiographs of PTPs, 56 panoramic and 72 lateral skull radiographs of DTPs, and 99 panoramic radiographs of age- and sex-matched HPs were selected. The fractal dimension values from panoramic radiographs were compared among HPs, PTPs, and DTPs and between anatomical locations within patient groups using analysis of variance with the Tukey test. Fractal dimension values from lateral skull radiographs were compared between PTPs and DTPs using the Student t-test. Pearson correlation coefficients were used to assess the relationship between the mandible from panoramic radiographs and the skull from lateral skull radiographs. Intra-examiner agreement was assessed using intraclass correlation coefficients (α=0.05). Results: The fractal dimension values were not significantly different among HPs, PTPs, and DTPs on panoramic radiographs or between PTPs and DTPs on lateral skull radiographs (P>0.05). The mandibular body presented the highest fractal dimension values (P≤0.05). The fractal dimension values of the mandible and skull in PTPs and DTPs were not correlated. Conclusion: Fractal analysis was not sensitive for distinguishing craniofacial trabecular bone complexity in multiple myeloma patients using panoramic and lateral skull radiography.

      • KCI등재

        Structural complexity of the craniofacial trabecular bone in multiple myeloma assessed by fractal analysis

        Michels Mariane,Morais-Faria Karina,Rivera César,Brandão Thaís Bianca,Santos-Silva Alan Roger,Oliveira Matheus L 대한영상치의학회 2022 Imaging Science in Dentistry Vol.52 No.1

        Purpose: This study aimed to evaluate the structural complexity of craniofacial trabecular bone in multiple myeloma by fractal analysis of panoramic and lateral skull radiography, and to compare the fractal dimension values of healthy patients (HPs), pre-treatment patients (PTPs), and patients during bisphosphonate treatment (DTPs). Materials and Methods: Pairs of digital panoramic and lateral skull radiographs of 84 PTPs and 72 DTPs were selected. After application of exclusion criteria, 43 panoramic and 84 lateral skull radiographs of PTPs, 56 panoramic and 72 lateral skull radiographs of DTPs, and 99 panoramic radiographs of age- and sex-matched HPs were selected. The fractal dimension values from panoramic radiographs were compared among HPs, PTPs, and DTPs and between anatomical locations within patient groups using analysis of variance with the Tukey test. Fractal dimension values from lateral skull radiographs were compared between PTPs and DTPs using the Student t-test. Pearson correlation coefficients were used to assess the relationship between the mandible from panoramic radiographs and the skull from lateral skull radiographs. Intra-examiner agreement was assessed using intraclass correlation coefficients (α = 0.05). Results: The fractal dimension values were not significantly different among HPs, PTPs, and DTPs on panoramic radiographs or between PTPs and DTPs on lateral skull radiographs (P>0.05). The mandibular body presented the highest fractal dimension values (P≤0.05). The fractal dimension values of the mandible and skull in PTPs and DTPs were not correlated. Conclusion: Fractal analysis was not sensitive for distinguishing craniofacial trabecular bone complexity in multiple myeloma patients using panoramic and lateral skull radiography.

      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼