        Flexural Capacity Prediction Model For Steel Fibre‑Reinforced Concrete Beams

        Aocheng Zhong,Massoud Sofi,Elisa Lumantarna,Zhiyuan Zhou,Priyan Mendis 한국콘크리트학회 2021 International Journal of Concrete Structures and M Vol.15 No.4

        Steel fibre (SF) reinforcement has been shown to improve the ductility of high strength concrete (HSC), which is known to be brittle. Research conducted to date on steel fibre reinforced concrete and its effects have emphasised post-failure performance and cracking mechanism. The difficulty in predicting the behaviour of fibres is due to the randomly distributed nature of the material within the matrix leading to a probability distribution of results. Published literature has shown a benefit of adding steel fibres in terms of the ductility performance of structures. Clearly, there is a potential for such material as replacement of conventional steel reinforcement. This study proposes a theoretical model of evaluating the potential of using steel fibres as a replacement material to conventional steel reinforcement bars based on the case study, laboratory and theoretical methodologies. The compressive strength of the concrete at key dates, the effective fibre cross-sectional were measured, and a prediction model was created based on the measurement parameters. The use of four-point flexural testing, standard compressive testing and software image modelling provided the study with relevant data used to analyse and compare to the prediction. Greater ductility performance and toughness were observed with increased fibre volumes, confirming proposed predictions and conclusion drawn from published literature. No consistent or conclusive correlations between fibre volumes and the compressive strength of concrete were found. A relationship between fibre volumes and predicted moment capacities of steel fibre reinforced concrete beams was found based on the proposed theoretical flexural analysis method.

      • KCI등재

        Ductility Design of Reinforced Very-High Strength Concrete Columns (100–150 MPa) Using Curvature and Energy-Based Ductility Indices

        Shanaka Kristombu Baduge,Priyan Mendis,Tuan Duc Ngo,Massoud Sofi 한국콘크리트학회 2019 International Journal of Concrete Structures and M Vol.13 No.5

        The paper aims to develop theoretical expressions for the ductility design of very-high strength concrete (VHSC)(> 100 MPa) columns using curvature and a new flexural energy-based ductility approach. Eventually, the study aims to evaluates the feasibility of VHSC columns for different ductility classes, considering the limitation of providing a higher volume of transverse reinforcement due to possible steel congestion in the construction phase. An analytical program based on the experimental stress–strain relationship of confined VHSC, which is validated using experimen-tal programs on VHSC columns, is used to evaluate the ductility of VHSC columns for different parameters such as axial load ratio, confinement pressure, longitudinal steel ratio, yield strength of transverse steel, cover area and compressive strength of concrete. The theoretical curvature ductility and flexural rotation-based energy ductility of 3200 rectan-gular columns were evaluated using the analytical program. Using curvature ductility and the new flexural rotation-based energy ductility for different parameters, a regression analysis is carried out to develop expressions for the ductility design of VHSC columns up to 150 MPa. Using the new definition of energy-based ductility, a new expression is developed for limited ductility design of VHSC; and it is concluded that the new approach reduces the required amount of steel confinement due to an increase in the energy ductility of VHSC at higher axial load ratios and higher strengths. The studies show that reinforced VHSC can be used for structures with nominal ductility demands.