백인수,Luc Mongeau,James E. Braun 대한기계학회 2010 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.24 No.9
The performance of a working prototype, operated with and without water flow through the heat exchangers, was measured and found to be in reasonably close agreement to predictions from a simulation code, DELTAE, based on linear thermoacoustic theory. Further analysis and DELTAE simulations showed that the coefficient of performance may be significantly reduced when the stack temperature profile becomes non-linear, i.e. when the system is operated for a temperature span smaller than the optimal value for a given stack length. Guidelines to avoid this condition are provided.
Phase of acoustic impedance and performance of standing wave thermoacoustic coolers
백인수,Luc Mongeau,James E. Braun,강신유 대한기계학회 2009 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.23 No.5
Investigations on the relations between the phase angle of the acoustic impedance at the driver piston and the system performance of a standing wave thermoacoustic cooler were performed. The system performance measured at a fixed acoustic power showed that the coefficient of performance of the standing wave thermoacoustic cooler increases as the phase angle increases when the stack temperature span is relatively low. The results were consistent with the simulation results obtained from DELTAE, a computer code based on linear thermoacoustic theory. Analysis on the temperature profiles along the stack showed that the cooling efficiency (COP) of the system could be decreased or increased as the phase angle of the acoustic impedance at the driver piston changes depending on the stack temperature spans.