Sipping Test: Checking for Failure of Fuel Elements at the OPAL Reactor
MICHAEL LESLIE SMITH,LINDSEY JORDEN BIGNELL,DIMITRI ALEXIEV1,LI MO 한국원자력학회 2010 Nuclear Engineering and Technology Vol.42 No.1
Sipping measurements were implemented at the Open Pool Australian Light water reactor (OPAL) to test for failure in reactor fuel elements. Fission product released by the fuel element into the pool water was measured using both High Purity Germanium (HPGe) detection via samples and a NaI(Tl) detection in-situ with the sipping device. Results from two fuel elements are presented.
SIPPING TEST: CHECKING FOR FAILURE OF FUEL ELEMENTS AT THE OPAL REACTOR
Smith, Michael Leslie,Bignell, Lindsey Jorden,Alexiev, Dimitri,Mo, Li Korean Nuclear Society 2010 Nuclear Engineering and Technology Vol.42 No.1
Sipping measurements were implemented at the Open Pool Australian Light water reactor (OPAL) to test for failure in reactor fuel elements. Fission product released by the fuel element into the pool water was measured using both High Purity Germanium (HPGe) detection via samples and a NaI(Tl) detection in-situ with the sipping device. Results from two fuel elements are presented.