Microsotructure Designed Porous Apatite Ceramics Prepared by Hydrothermal Method
Ioku, Koji,Fukuhara, Michiko,Fujimori, Hirotaka,Goto, Seishi The Korean Ceramic Society 1999 The Korean journal of ceramics Vol.5 No.2
Microsotructure designed porous ceramics of calcium hydroxyapatite $(Ca_{10}(PO_4)_6(OH)_2)$ were prepared by hydrothermal method. The particle size, shape, and the micro-pore size of the porous hydroxyapatite ceramics could becontrolled. The hydroxyapatite was non-stoichiometric apatite with calcium deficient compositions (Ca/P ratio < 1.67). The composition of non-stoichiometric hydroxyapatite ceramics could be controlled from 1.50 to 1.63 in Ca/P ratio. The hydroxyapatite ceramics preparedc at $105^{\circ}C$ under the saturated vapor pressure for 20h were composed of rod-shaped crystals with about 10$\mu\textrm{m}$ in length with the mean aspect ratio of 40. The porous ceramics of calcium deficient hydroxyapatite had about 45% porosity with the inter-connecting pore structure. Porous hydroxyapatite ceramics prepared hydrothermally had the compressive strength of about 10 to 30 MPa. In addition, porous ceramics of $\beta$-tricalcium phosphate ($\beta-Ca_3(PO_4)_2$) were prepared from the calcium deficient hydroxyapatite.
In Vitro Reaction for Calcium Phosphate Ceramics
Ioku, Koji,Toya, Hiroyuki,Fujimori, Hirotaka,Goto, Seishi The Korean Ceramic Society 2000 The Korean journal of ceramics Vol.6 No.3
Hydroxyapatite (HA) and $\beta$-tricalcium phosphate ($\beta$-TCP) are bio-compatible materials with bones and teeth. HA has been widely applied as bone substitutes because of chemical stability in vivo, while $\beta$-TCP has higher resorbability than HA when the material is implanted in a bone defect. In the present study, both HA and $\beta$-TCP porous ceramics were soaked in the simulated body fluid in order to investigate the reaction between the materials and the fluid. After the soaking test, carbonate hydroxyapatite was formed on HA surface at 1 week, and then the amount of precipitates increased with increasing period of the soaking test. While $\beta$-TCP was not dissolved in the fluid, carbonate hydroxyaopatite was also formed on $\beta$-TCP surface after 12 weeks, and the amount of precipitates was less than that on HA. In vitro behavior of HA was similar to that in vivo, but in vitro behavior of $\beta$-TCP was not similar to that in vivo.
Ioku Tetsuya,Ohshima Tomotaka,Yokota Mao,Matsuo Naoki,Miyachi Shigeru 대한신경중재치료의학회 2023 Neurointervention Vol.18 No.3
Transarterial embolization using Onyx is a well-established treatment for dural arteriovenous fistulas (DAVFs). However, complications can arise when Onyx migrates into the venous side, impairing the draining veins. We encountered a case where Onyx, injected through the arterial side, strayed into the jugular vein, forming a hairball-like structure. Our study aimed to investigate the underlying mechanism of this unusual phenomenon. We postulated that Onyx precipitates into thread-like shapes when passing through extremely narrow openings. To test this, we extruded Onyx from a syringe through a 27-gauge needle into a silicone tube with flowing water. By varying the flow speed, we observed the hardening behavior of Onyx. Under slow flow, the extruded Onyx quickly solidified at the needle tip, forming a round mass. Conversely, high-speed flow resulted in Onyx being dispersed as small pieces. We successfully replicated the formation of “Onyx threads” under continuous slow flow conditions, similar to our case. This phenomenon occurs when Onyx unexpectedly migrates to the draining vein through a tiny opening during transarterial embolization for arteriovenous shunt diseases. Early recognition and appropriate measures are necessary to prevent occlusive complications in the draining veins and the pulmonary system.
A Novel Training Method for Endovascular Clot Retrieval Using a Portable Vascular Model and Red Film
Ioku Tetsuya,Ohshima Tomotaka,Kawaguchi Reo,Matsuo Naoki,Miyachi Shigeru 대한신경중재치료의학회 2024 Neurointervention Vol.19 No.2
Hands-on training is a crucial part of education in neuroendovascular treatment to ensure safe and rapid acquisition of techniques. However, there is a significant gap between training and actual clinical practice. This study will introduce innovations for more practical thrombus retrieval training that was developed in this process. A Smart Vascular Model 3 in 1 was used. A pink pseudothrombus was inserted into the M1 (horizontal segment of the middle cerebral artery) section of the model. Then, a “red underlay” purchased at a stationery store was placed to cover the proximal part of M1 and beyond so that the pseudothrombus was not visible. The thrombus was retrieved during training by looking for the location of the thrombus based on the behavior and resistance of the tip of the guidewire and deployment of the stent retriever. The participants were required to have detailed observation skills and precise manipulation skills using a red film to prevent the direct visualization of the pseudothrombus. The implementation of this innovation to the previous hands-on training made the training more practical and effective. If the exact thrombus location can be determined by the behavior of the wire tip, the device’s capabilities can be maximized, and rapid retrieval can be expected. It could also reduce complications, as unnecessary peripheral guidance of the device could be avoided.
${29}^Si$ MAS NMR Study on Quantitative Analysis of the Amorphous Phase in a $Si_3N_4$ Powder
Fujimori, Hirotaka,Kitahara, Hiromoto,Ioku, Koji,Goto, Seishi,Nakayasu, Tetsuo,Yamada, Tetsuo The Korean Ceramic Society 2000 The Korean journal of ceramics Vol.6 No.2
NMR study has been used for measuring precise quantity of the amorphous phase in the $Si_3N_4$powder. Care must be taken to allow the $^{29}$Si nuclear spin system to fully relax between pulses in order to make the signals proportional to the number of nuclei in each phase. $^{29}$Si MAS spectrum was decomposed into the three spectra of $\alpha$-, $\beta$-, and amorphous $Si_3N_4$assuming pseudo-Voigt function. Moreover, the Rietveld analysis of the powder X-ray diffraction data was performed to measure quantity of crystalline phases as $\alpha/\beta$ ratio.
Application of DV-X$\alpha$ Method to ${\gamma}$-2CaO.SiO$_2$
Yamaguchi, Norio,Fujimori, Hirotaka,Ioku, Koji,Goto, Seishi,Nakayasu, Tetsuo The Korean Ceramic Society 2000 The Korean journal of ceramics Vol.6 No.4
In the present study, we attempted to apply DV-X$\alpha$ method to expressing the reactivity of materials. The expression of reactivity was discussed by comparison between ${\gamma}$-C$_2$G having hydraulic activity and ${\gamma}$-C$_2$S not having hydraulic activity at normal conditions. It was found that the model cluster used for calculation can finely reproduce the bulk and surface states using with and without point charge, respectively. The hydration state was also represented by placing OH ̄ on the surface of the cluster. It was calculated that the bond strength of the first layer (as surface) was bigger than that of inner layers (as bulk) for ${\gamma}$-C$_2$S while that of the first layer for ${\gamma}$-C$_2$G was smaller than that of inner layers. Subsequently a model in which OH ̄ is coordinated on Ca at the surface was also calculated. The bond strength with OH ̄ was stronger than that without OH ̄, while for ${\gamma}$-C$_2$G the bond strength with OH ̄ was weaker than that without OH ̄. From these results, it is concluded that the hydraulic activity depends on whether the bond strength for hydrated state becomes weaker than that unhydrated state or not.
Preparation of Carbon Composite with High Oxidation Resistance by MoSi2 Dispersion
Goto, S.,Kodera, M.,Toda, S.,Fujimori, H.,Ioku, K. The Korean Ceramic Society 1999 The Korean journal of ceramics Vol.5 No.2
Carbon composites with $MoSi_2$ dispersion were prepared by hot-pressing at $1700^{\circ}C$ under 30 MPa for 1 h using polysilazance as binding material. The composites consisted of C, $Mo_{4.8}Si_3C_{0.6}$ and SiC. Bulk density and porosity of the carbon composites with 10 vol% $MoSi_2$ was 1.8g.$\textrm{cm}^{-3}$ and 34%, respectively. This composite was oxidized about 0.05mm from the surface of the carbon composite after oxidation test at $1500^{\circ}C$ for 10h in air. Formation of the $SiO_2$ glass layer was observed by SEM. When this composite suffered damage in the coating layer, it had hardly farther oxidation because of its self-repairing property. The composite prepared in this study indicated good oxidation resistance.