정인성(In-Sung Jeong),최효상(Hyo-Sang Choi) 대한전기학회 2013 전기학회논문지 Vol.62 No.6
Interest in Wireless Power Transmission (WPT) technology has been increasing worldwide recently. This trend is proved by commercialized products such as electric toothbrush, wireless razor, and wireless charger for mobile phone battery. Studies for enhancing the applicability of the technology have been continuously conducted. Currently the WPT technology is based on the technologies using microwave, inductively coupling, and magnetic resonance. In the meantime, development of the microwave-based WPT faces difficulty due to health hazards involved in the technology, and application of the WPT technology using inductively coupling is restricted by area due to the problem of transmission length. In comparison, the WPT technology using magnetic resonance draws attention in terms of efficiency and transmission length. In this study, the sending coil based on the WPT technology using magnetic resonance system was replaced with an HTS coil to enhance transmission efficiency. Since the HTS coil has a zero resistance, power transmission loss can be minimized. At the same time, size of the current density could be increased to 100 times or more than typical coils. In addition, through impedance matching of LC device, maximal resonance properties were induced and consequently, frequency selection quality characteristics or Q was enhanced. As a result, the WPT type using the HTS coil showed a longer transmission length and better transmission efficiency compared with the WPT type using typical coils.
정인성(In-Sung Jeong),최효상(Hyo-Sang Choi),정병익(Byung-Ik Jung) 대한전기학회 2013 전기학회논문지 Vol.62 No.2
With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.