RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

        ( Gi Ryon Kim ),( Dong Keun Jung ),( Soo Young Ye ),( Jae Hung Kim ),( Gye Rok Jeon ) 한국센서학회 2008 센서학회지 Vol.17 No.2

        Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ± 3.240 mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ± 1.807 mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ± 5 mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

      • Color Correction in Portable-type Urine Analyzer

        jae-HyungKim,ChangHeePark,SeungJinLee,GyeRokJeon,GiRyonKim 한국전기전자재료학회 2002 Transactions on Electrical and Electronic Material Vol.3 No.4

        Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼