Radial Thrust of Single-Blade Centrifugal Pump
Nishi, Yasuyuki,Fukutomi, Junichiro,Fujiwara, Ryota Korean Society for Fluid machinery 2011 International journal of fluid machinery and syste Vol.4 No.4
Single-blade centrifugal pumps are widely used as sewage pumps. However, the impeller of a single-blade pump is subjected to strong radial thrust during pump operation because of the geometrical axial asymmetry of the impeller. Therefore, to improve pump reliability, it is necessary to quantitatively understand radial thrust and elucidate the behavior and mechanism of thrust generating. This study investigates the radial thrust acting up on a single-blade centrifugal impeller by conducting experiments and CFD analysis. The results show that the fluctuating component of radial thrust increases as the flow rate deviates from the design flow rate to low or high value. Radial thrust was modeled by a combination of three components, inertia, momentum, and pressure by applying an unsteady conservation of momentum to the impeller. The sum of these components agrees with the radial thrust calculated by integrating the pressure and the shearing stress on the impeller surface. The behavior of each component was shown, and the effects of each component on radial thrust were clarified. The pressure component has the greatest effect on the time-averaged value and the fluctuating component of radial thrust. The time-averaged value of the inertia component is nearly 0, irrespective of the change in the flow rate. However, its fluctuating component has a magnitude nearly comparable with the pressure component at a low flow rate and slightly decreased with the increase in flow rate.
Unsteady Flow Condition of Centrifugal Pump for Low Viscous Fluid Food
Shigemitsu, Toru,Fukutomi, Junichiro,Matsubara, Takumi,Sakaguchi, Masahiro Korean Society for Fluid machinery 2017 International journal of fluid machinery and syste Vol.10 No.4
Fluid machineries for fluid food have been used in wide variety of field i.e. transportation, filling, and improvement of quality of fluid food. The flow condition of these fluid machineries is quite complicated because the fluid food is different from water. Therefore, a design method based on the internal flow condition is not conducted. In this research, a turbo-pump having small number of blades was used to decrease shear loss and keep wide flow passage. In previous studies, it was found that internal flow condition was complex in the test pump, but those flow phenomena were not clarified in detail. In order to investigate the complex internal flow condition, the unsteady numerical analysis using low viscous fluid was conducted. In this paper, the relation between the blade geometry and the performance was investigated. In addition to that, the internal flow condition of the centrifugal pump using low viscous fluid was clarified by the numerical analysis results.
Shigemitsu, Toru,Fukutomi, Junichiro,Shimizu, Hiroki Korean Society for Fluid machinery 2012 International journal of fluid machinery and syste Vol.5 No.4
Small-sized axial fans are used as air coolers for electric equipment. There is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of the efficiency and the increase of noise. Then, the adoption of contra-rotating rotors for small-sized fans is proposed for the improvement of the performance. In the case of contra-rotating rotors, blade row distance between the front and the rear rotors influences on the performance and the noise. Therefore, it is important to clarify the optimum blade row distance between front and rear rotors. The performance curves of the contra-rotating small-sized axial fan under the condition of different blade row distances are shown and the blade row interaction between the front and the rear rotors are discussed by the numerical results. Furthermore, the optimum blade row distance of the contra-rotating small-sized axial fan is considered.
Shigemitsu, Toru,Fukutomi, Junichiro,Kaji, Kensuke Korean Society for Fluid machinery 2011 International journal of fluid machinery and syste Vol.4 No.3
Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields; automobile radiator pump, ventricular assist pump, cooling pump for electric devices and so on. Further, the needs for mini centrifugal pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini centrifugal pump design be as simple as possible as precise manufacturing is required. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, we started research on the mini centrifugal pump for the purpose of development of high performance mini centrifugal pumps with simple structure. Three types of rotors with different outlet angles are prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the outlet angle on performance and internal flow condition of mini centrifugal pumps. In addition to that, the blade thickness is changed because blockage effect in the mini centrifugal pump becomes relatively larger than that of conventional pumps. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-Fluent) to investigate the internal flow condition. It is clarified from the experimental results that head of the mini centrifugal pump increases according to the increase of the blade outlet angle and the decrease of the blade thickness. In the present paper, the performance of the mini centrifugal pump is shown and the internal flow condition is clarified with the results of the experiment and the numerical flow analysis. Furthermore, the effects of the blade outlet angle and the blade thickness on the performance are investigated and the internal flow of each type of rotor is clarified by the numerical analysis results.
A Study of Performance and Internal Flow in a New Type of Sewage Pump
Nishi, Yasuyuki,Fukutomi, Junichiro Korean Society for Fluid machinery 2009 International journal of fluid machinery and syste Vol.2 No.3
Sewage pumps are designed with a wide flow channel by, for example, sacrificing some efficiency and reducing the number of blades, in order to prevent plugging with foreign bodies. However, the behavior of foreign bodies which actually flow into a pump is extremely complex, and there are questions about whether the presumed foreign bodies will actually pass through. This paper proposes a new type of sewage pump impeller designed to further improve pump efficiency and performance in passing foreign bodies. This sewage pump impeller has a structure in which the suction flow channel of a closed type non-clog pump is wound in a helical spiral. The focus of this research was to investigate pump performance and internal flow in this single blade sewage pump impeller. The results clearly indicated the following facts: The developed sewage pump impeller exhibits high efficiency over a wide range of flow rates; internal flow of the pump is very complicated; and the internal flow state varies greatly when the flow rate changes.
Performance and Internal Flow Condition of Mini Centrifugal Pump with Splitter Blades
Shigemitsu, Toru,Fukutomi, Junichiro,Kaji, Kensuke,Wada, Takashi Korean Society for Fluid machinery 2013 International journal of fluid machinery and syste Vol.6 No.1
Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. Blade-to-blade low velocity regions are suppressed in the case with the splitter blades and total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.
Internal Flow Condition of High Power Contra-Rotating Small-Sized Axial Fan
Shigemitsu, Toru,Fukutomi, Junichiro,Agawa, Takuya Korean Society for Fluid machinery 2013 International journal of fluid machinery and syste Vol.6 No.1
Data centers have been built with spread of cloud computing. Further, electric power consumption of it is growing rapidly. High power cooling small-sized fans; high pressure and large flow rate small-sized fan, are used for servers in the data centers and there is a strong demand to increase power of it because of increase of quantity of heat from the servers. Contra-rotating rotors have been adopted for some of high power cooling fans to meet the demand for high power. There is a limitation of space for servers and geometrical restriction for cooling fans because spokes to support fan motors, electrical power cables and so on should be installed in the cooling fans. It is important to clarify complicated internal flow condition and influence of a geometric shape of the cooling fans on performance to achieve high performance of the cooling fans. In the present paper, the performance and the flow condition of the high power contra-rotating small-sized axial fan with a 40mm square casing are shown by experimental and numerical results. Furthermore, influence of the geometrical shape of the small-sized cooling fan on the internal flow condition is clarified and design guideline to improve the performance is discussed.