http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors
Bienati, B.,Bottino, A.,Comite, A.,Ferrari, F.,Firpo, R.,Capannelli, G 한국막학회 2007 멤브레인 Vol.17 No.2
The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.
Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors
G Capannclli,B. Bienati,A. Bottino,A. Comite,F. Ferrari,R. Firpo 한국막학회 2007 멤브레인 Vol.17 No.2
The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.
Eman Z. Al-Shehri,Afnan O. Al-Zain,Alaa H. Sabrah,Sarah S. Al-Angari,Laila Al Dehailan,George J. Eckert,Mutlu Özcan,Jeffrey A. Platt,Marco C. Bottino 대한치과보존학회 2017 Restorative Dentistry & Endodontics Vol.42 No.3
Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide (Al2O3) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and χ2 tests (α = 0.05). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.
Al-Shehri, Eman Z.,Al-Zain, Afnan O.,Sabrah, Alaa H.,Al-Angari, Sarah S.,Dehailan, Laila Al,Eckert, George J.,Ozcan, Mutlu,Platt, Jeffrey A.,Bottino, Marco C. The Korean Academy of Conservative Dentistry 2017 Restorative Dentistry & Endodontics Vol.42 No.3
Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.