http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이응장,김보람,안홍규,박승한,정은지,이상엽 한국물리학회 2015 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.66 No.4
A video-rate multimodal microscope, which can obtain second- and third- harmonic generation(SHG and THG) images simultaneously, is developed for investigating cellular and tissue structuresin mouse ear skin. By utilizing in-vivo video-rate epi-detected SHG and THG microscopy, wesuccessfully demonstrate that combined images of subcutaneous cellular components and peripheralnerve fibers, together with the collagen fiber, in the mouse ear pinna can be obtained withoutemploying fluorescent probes. We also show that the flow of red blood cells and the diameter changeof arteriole-like blood vessels can be visualized with femtosecond laser pulses with a wavelength of1036 nm. In particular, the epi-THG contrast images of the blood-vessel walls display clearly thedifference between the arteriole-like and the venule capillary-like blood-vessel types. We shouldemphasize that our newly-developed microscope system has a unique feature in that it can producesimultaneous in-vivo label-free SHG and THG images in contrast to the conventional confocal andtwo-photon microscopes.
최소 부피 광음향 셀의 광음향 신호 재현성 향상에 관한 연구
김경석,이규승,안홍규,이응장,김대규,박승한,Kim, Kyong-Seok,Lee, Kew-Seung,Ahn, Hong-Gyu,Lee, Eung-Jang,Kim, Dae-Kyu,Park, Seung-Han 한국광학회 2011 한국광학회지 Vol.22 No.2
Reproducibility obtained by a minimum-volume cell for photoacoustic (PA) signals is strongly dependent upon the sealing materials and sealing efficiency. Therefore, we have proposed, designed, and constructed an apparatus to enhance the sealing efficiency, and we have examined the reproducibility of amplitude and phase of PA signals with a minimum-volume cell. In particular, we have measured the PA signal as a function of modulation frequency for various rubber O-rings by using our apparatus. The results show that a silicon rubber O-ring can improve the reproducibility of the PA signal and phase by up to 53.4% and 80.4%, respectively, compared to that obtained by using the conventional sealing material, vacuum grease. 광음향 분광학 연구에 빈번히 사용되는 최소 부피 개방형 광음향 셀을 이용하여 광음향 신호를 측정할 경우 최소 부피 광음향셀의 밀폐상태는 광음향 신호의 재현성에 큰 영향을 미친다. 따라서 본 논문에서는 최소 부피 광음향 셀의 밀폐 효율을 높일 수 있는 고무오링 밀폐재를 적용한 구조를 설계하고 제작한 후, 제작한 구조체를 이용하여 다양한 재질의 고무 오링에 대한 광음향 신호를 주파수 별로 측정하고 분석하였다. 실험 결과 진공 그리스를 이용하여 광음향 셀을 밀폐하는 기존의 방식과 비교했을 때, 실리콘 고무 오링을 밀폐재로 사용하는 경우 광음향 신호의 진폭과 위상의 재현성이 각각 최대 53.4%와 80.4%까지 향상될 수 있음을 알 수 있었다.