김창훈,권평규,홍준서,지남용 대한건축학회 2000 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.20 No.2
Although glass has been used as indoor and outdoor walls for a fine view or lighting, the fracture made by thermal stress has possibility to cause smog transmission and flame spread to adjacent space. Radiation heat transmitted through the surface of glass is enough to bum combustible materials which is attached to the inside of a fire room, In oder to prevent above those, the preceding research has reported that water film covered glazing system could secure fire resistance capacity for 2 hours in case that it makes water film spreaded on the surface of glass, perfectly. This study aimed to obtain the configuration of fractures, the maximum exposed temperatures, allowable strains due to the various surface temperatures with each thickness of sheet glass and tempered glass before operating water film covered glazing system.