http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
成犬下顆骨에서 TITANIUM 및 CARBON-COAT ED BLADE-VENT人工齒牙의 周圍組織反應
朴金诛,(Keum-Soo Park),崔牧均(Mok-Kyun Choie),金鴻基(Hong-Ki Kim),金光兹,(Kwang-Hyun Kim),Chang Bae 대한치과이식임플란트학회 1986 The Korean Academy of Implant Dentistry Vol.7 No.1
In order to investigate the influence o f implant materials, functional stress and width of channel on the tissue reaction around implants, the tissues around the endosseous implants were observed histopathologically. The manflibular left 2nd,3rd and 4th premolars o f 12 healthy dogs (25-40 kg body weight) were extracted. Three months after extraction, pure titanium blade-vent implants (K.L. Blade Implant, DAE WON KANG UP Co., Ltd., KOREA Design by Dr. H.K. KIM) and carbon-coated titanium implants (K.L. Blade Implant, DAE WON KANG UP Co., Ltd., KOREA Design by Dr. H.K. KIM) were implanted into the 3rd premolar regions seperately. For implantation, 12 dogs were divided into 6 groups as follows; GroupⅠ(functional implant); Implantation o f titanium blade-vent implant with cone-shaped chrome-cobalt crown into the narrow channel (width approximately 1 mm, which was almost equal to that o f implant). GroupⅡ(non-functional implant); Implantation of titanium balde-vent implant without head into the narrow channel (width approximately 1 mm). A GroupⅢ(non-functional implant); Implantation of titanium blade-vent implant without head into the wide channel (width approximately 2.5 mm, which was 1.5 mm wider than that of implant). GroupⅣ(functional implant); Implantation of carbon-coated blade-vent implant by the same method as group I. GroupⅤ(non-functional implant); Implantation of carbon-coated implant by the same method as groupⅡ. GroupⅥ(non-functional implan狀 Implantation o f carbon-coated implant by the same method as groupⅢ. Six months after implantation, the tissue blocks containing the implants were removed. These block sections were fixed in 10% neutral buffered formalin for 2 days and decalcified in 15% formic acid. The buccal side of the blocks were removed with a knife and the implants were detached from the blocks. The tissue blocks were embedded by paraffin embedding method and then sectioned by 5-7 jum thickness. Those specimens were stained with hematoxylin and eosin. The results obtained were as follows. 1. Fibrous capsules existed around the functional implants, but were not observed around the non-functional implants embedded into the narrow channels. 2. Fibrous capsules were observed around the implants inserted into the wide channel even though they were embedded into the bone. 3. There was little difference between the tissue reaction to the pure titanium implants and that to the carbon-coated implants. 4. No abnomal changes were found in the fibrous connective tissue and the osseous tissue around the titanium and carbon-coated implants.
南光20857,朴兌影,趙信據,金結 대한신경정신의학회 1974 신경정신의학 Vol.13 No.4
Study on the Korean standard MMPI was performed on 154 active tuberculosis patients who were admitted in the National Masan Tuberculosis Hospital Emphasis was made that tuberculosis is a chronic wasting physical illness and shows many neuropsychiatric problems in its course. Patients were divided into 3 groups, namely, minimal, moderate advanced, and far advanced group. The following results were obtained. 1. A high validity score around 50 in L. F. K. sacle was noted. 2. As for the clinical neurotic scale of Hs, D. H y ., the normal regular pattern was noted in the minimal group and the moderately and far advanced gorup showed a significant increase in the score rather proportional to the disease course. 3. Although the clinical psychotic scale was within the normal range, there was a tendency of increase in the score as the morbid state progressed. 4 There appeared no significant relationship between the progress of morbid state and behavior disorder scale or Si scale, respectively. 5. In general, male patients showed an increase of score as compared to the female patients.
시멘트 종류에 따른 티타늄 임프란트에 대한 주조체의 유지력
崔牧均,聚昶,崔丙哲,金光兹 대한치과이식임플란트학회 1989 The Korean Academy of Implant Dentistry Vol.9 No.1
The purpose of this investigation was to test the retention of the castings to titanium implants in dental cements. After making copings with type IE gold, noble metal alloy for ceramics and base metal alloy for ceramics, we cemented them on the abutment of titanium implant with zinc phosphate cement, polycarboxylate cement and glass ionomer cement, and then tested the retention force on an Instron. The results of this study were as follows: 1. The zinc phosphate cement was distinctly superior to polycarboxylate cement and glass ionomer cement regardless of types of alloy in retentive force. 2. There was no statistically significant difference between polycarboxylate cement and glass ionomer cement. 3. Little difference was observed in the retentive forces of three types of alloy regardless of cements.