http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Paul, Saroj Kumar,Dash, Upendra N. Korean Society for Mass Spectrometry 2015 Mass spectrometry letters Vol.6 No.2
Roflumilast analogs are a group of drugs which act as selective photodiesterase (PDE-4) inhibitor for the treatment severe chronic pulmonary disease associated with chronic brochnonities. Structural identification of degradation products using high resolution mass spectrometry and theoretical investigation by density functional theory have been successfully carried out on roflumilast to identify four degradation products namely, 3,5-dichloropyridin-4-amine, N-(3,5-dichloropyridin-4-yl)-4-(difluoromethoxy)-3-hydroxy benzamide, N-(3,5-dichloropyridin-4-yl)-3-(cyclopropylmethoxy)-4-(difluoromethoxy) benzamide and 3-(cyclopropylmethoxy)-N-(3,5-dichloro-1-oxidopyridin-4-yl)-4-(difluoro methoxy) benzamide, generated in alkali, acidic and oxidative conditions.
( Saroj Kumar Paul ),( Upendra N. Dash ) 한국질량분석학회 2015 Mass spectrometry letters Vol.6 No.2
Roflumilast analogs are a group of drugs which act as selective photodiesterase (PDE-4) inhibitor for the treatment severe chronic pulmonary disease associated with chronic brochnonities. Structural identification of degradation products using high resolution mass spectrometry and theoretical investigation by density functional theory have been successfully carried out on roflumilast to identify four degradation products namely, 3,5-dichloropyridin-4-amine, N-(3,5-dichloropyridin-4-yl)-4-(difluoromethoxy)-3-hydroxy benzamide, N-(3,5-dichloropyridin-4-yl)-3-(cyclopropylmethoxy)-4-(difluoromethoxy) benzamide and 3-(cyclopropylmethoxy)-N- (3,5-dichloro-1-oxidopyridin-4-yl)-4-(difluoro methoxy) benzamide, generated in alkali, acidic and oxidative conditions.
Upendra N. Dash and Saroj Kumar Paul 사단법인 한국질량분석학회 2012 Mass spectrometry letters Vol.3 No.3
The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to beused as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquaticecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of sixanionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization(ESI) mass spectrometer (MS), in the concentration range 15-20 μg/L. The capability of the method was establishedusing regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with1-dodecyl hydrogen sulfate at 15 μg/L. Combined efficiency of solid phase extraction and MS detection established recovery of89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerfultechnique for environmental applications concerning the screening of polar contaminants.
Dash, Upendra N.,Paul, Saroj Kumar Korean Society for Mass Spectrometry 2012 Mass spectrometry letters Vol.3 No.3
The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to be used as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquatic ecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of six anionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization (ESI) mass spectrometer (MS), in the concentration range 15-20 ${\mu}g/L$. The capability of the method was established using regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with 1-dodecyl hydrogen sulfate at 15 ${\mu}g/L$. Combined efficiency of solid phase extraction and MS detection established recovery of 89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerful technique for environmental applications concerning the screening of polar contaminants.
( Upendra N. Dash ),( Saroj Kumar Paul ) 한국질량분석학회 2012 Mass spectrometry letters Vol.3 No.3
The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to be used as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquatic ecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of six anionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization (ESI) mass spectrometer (MS), in the concentration range 15-20 μg/L. The capability of the method was established using regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with 1-dodecyl hydrogen sulfate at 15 μg/L. Combined efficiency of solid phase extraction and MS detection established recovery of 89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerful technique for environmental applications concerning the screening of polar contaminants.