      Potentiometric determination of iron in polluted water samples using new modified Fe(III)-screen printed ion selective electrode

      한글로보기

      https://www.riss.kr/link?id=A104707355

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This article is focused on the determination of Fe(III) ion as an important factor in water pollution. A potentiometric method based on screen-printed ion-selective electrode was described for the determination of Fe(III) ion in different polluted wat...

      This article is focused on the determination of Fe(III) ion as an important factor in water pollution. A potentiometric method based on screen-printed ion-selective electrode was described for the determination of Fe(III) ion in different polluted water samples. It is based on incorporation of the Fe-phosphotungstate ion-associate in a screen-printed electrode (SPE) composition and tricresylpho-sphate (TCP) as plasticizer. The influences of the paste composition, different conditioning parameters and foreign ions on the electrode performance were investigated. The reversibility and also response time of the electrode have been studied. The electrode showed Nernstian response of 19.20 ± 0.73 mV decade-1 in the concentration range of 1 × 10-7–2.5 × 10-2 mol L-1. The electrode was found to be usable within the pH range of 3–7.5 and exhibited a fast response time (about 7 s), low detection limit (1.57 × 10-7 mol L-1), long lifetime (>6 months) and good stability. The isothermal temperature coefficient (dE0/dt) of the electrode was calculated. The electrode was successfully applied for the determination of Fe(III) ion in pure solutions and polluted water samples (formation, tab and sea water samples) using potentiometric determination technique. The results obtained applying this potentiometric electrode is comparable with those obtained using inductive coupled plasma technique.

      더보기

      참고문헌 (Reference)

      1 M. Masrournia, 31 : 574-, 2011

      2 H. A. Zamani, 32 : 564-, 2012

      3 V. K. Gupta, 117 : 99-, 2006

      4 M. J. Seguı´, 71 : 333-, 2007

      5 M. H. Mashhadizadeh, 64 : 1048-, 2004

      6 P. K. Dasgupta, 58 : 153-, 2002

      7 M. F. D. S. Teixeira, 9 : 506-, 1998

      8 D. Wilson, 181 : 140-, 2010

      9 M. Aghaie, 247 : 346-, 2009

      10 P. Kumar, 77 : 1057-, 2009

      1 M. Masrournia, 31 : 574-, 2011

      2 H. A. Zamani, 32 : 564-, 2012

      3 V. K. Gupta, 117 : 99-, 2006

      4 M. J. Seguı´, 71 : 333-, 2007

      5 M. H. Mashhadizadeh, 64 : 1048-, 2004

      6 P. K. Dasgupta, 58 : 153-, 2002

      7 M. F. D. S. Teixeira, 9 : 506-, 1998

      8 D. Wilson, 181 : 140-, 2010

      9 M. Aghaie, 247 : 346-, 2009

      10 P. Kumar, 77 : 1057-, 2009

      11 Tamer Awad Ali, 42 : 1336-, 2013

      12 L. Authier, 10 : 1255-, 1998

      13 D. V. Chernyshov, 18 : 88-, 2008

      14 L. Tymecki, 96 : 482-, 2003

      15 L. Tymecki, 34 : 71-, 2001

      16 R. Koncki, 385 : 451-, 1999

      17 E. Khaled, 135 : 74-, 2008

      18 Tamer Awad Ali, 8 : 1469-, 2013

      19 Gehad G. Mohamed, 673 : 79-, 2010

      20 E. Y. Z. Frag, 7 : 4443-, 2012

      21 Gehad G. Mohamed, 22 : 2587-, 2010

      22 Gehad G. Mohamed, 136 : 1488-, 2011

      23 Gehad G. Mohamed, 4 : 1009-, 2012

      24 A. K. Singh, 19 : 1213-, 2007

      25 R. K. Mahajan, 326 : 191-, 2008

      26 F. A. Nour El-Dien, 7 : 10266-, 2012

      27 R. P. Buck, 66 : 2527-, 1994

      28 R. Matesic-Puac, 106 : 221-, 2005

      29 F. J. Sa’ez de Viteri, 119 : 749-, 1994

      30 H. Boudouh, 133 : 383-, 2012

      31 V. K. Gupta, 71 : 1964-, 2007

      32 G. Ekmekci, 288 : 36-, 2007

      33 A. Sil, 106 : 648-, 2005

      34 M. Bralic´, 63 : 777-, 2004

      35 M. G. Motlagh, 55 : 6724-, 2010

      36 M. Bralic´, 27 : 57-, 1999

      37 V. S. Bhat, 99 : 98-, 2004

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 3.4 0.75 2.84
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      2.39 2.24 0.397 0.56
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼