RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      Clinical Efficacy and Complications of Intraocular Lens Exchange for Opacified Intraocular Lenses

      한글로보기

      https://www.riss.kr/link?id=A106180879

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To evaluate the clinical efficacy and complications of intraocular lens (IOL) exchange. Methods: A review of medical records was performed for 52 eyes that had undergone an IOL exchange due to IOL opacification. Surgical complications and the...

      Purpose: To evaluate the clinical efficacy and complications of intraocular lens (IOL) exchange. Methods: A review of medical records was performed for 52 eyes that had undergone an IOL exchange due to IOL opacification. Surgical complications and their incidences were analyzed. The mean best corrected visual acuity (BCVA) after the IOL exchange was compared with the mean pre-exchange BCVA and with the mean BCVA after the initial IOL implantation. Prediction error of refraction and biometric data obtained for the IOL exchange were, if available, compared with those obtained for the initial IOL implantation. The prediction error for the IOL exchange, calculated from the biometric data obtained before the IOL exchange, was compared with that calculated from the measurements obtained before the initial IOL implantation. Results: The overall complication rates were low and no serious complications were found. The mean BCVA improved significantly after the IOL exchange and was not significantly different from that obtained after the initial IOL implantation. However, the refractive prediction for the IOL exchange was not as good as it was for the initial IOL implantation, which was thought to be related with difficulties in axial length (AL) measurements. Biometric data taken before the initial IOL implantation was associated with a significantly better refractive prediction than those taken before the IOL exchange. Conclusions: IOL exchange was both efficacious and safe for visual recovery. However, IOL exchange was related with increased difficulty of predicting postoperative refraction; difficulties in AL measurements are the suggested cause.

      더보기

      목차 (Table of Contents)

      • Materials and Methods Results Discussion
      • Materials and Methods Results Discussion
      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼