RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보

      RC 라멘조 발파해체 적용사례와 기술,경제적 성과분석 -대전 중앙데파트 발파해체사례를 중심으로- = A Case Study of RC Rahmen Structure Explosives Demolition(Focusing Demolition at Chungang Department in Daejeon City)

      한글로보기

      https://www.riss.kr/link?id=A82595396

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Domestic explosive demolition techniques have been developed and applied for low-rise structures up to now. However, the demand for the development of those techniques that can be applied economically, safely and environment-friendly rapidly increases because the old high-rise RC rahmen structures that were built since around 1970s are now required to rebuild. As a result, element technologies of explosive demolition for low-rise structures were applied to take advantage of technology in high-rise structures that performed application testing at Chungang Department demolition field in Daejeon city. It could judge elements technology establishment for high-rise structure demolition and field application and suggest the improvements when the problems occurred to develop High-rise building demolition techniques for method of protection a field test and the dust reduction test. The water cannon test was applied to reduce the dust site and the drilling tests are performed to select the best components for explosives demolition elements techniques of the reliability. This paper shows that we have the ability to remove a high-rise building using environmentally friendly safe and economical explosives demolition method. It would contribute to prevent a foreign company from entering the domestic market and should contribute to acquire competitiveness of domestic demolition industry.
      번역하기

      Domestic explosive demolition techniques have been developed and applied for low-rise structures up to now. However, the demand for the development of those techniques that can be applied economically, safely and environment-friendly rapidly increases...

      Domestic explosive demolition techniques have been developed and applied for low-rise structures up to now. However, the demand for the development of those techniques that can be applied economically, safely and environment-friendly rapidly increases because the old high-rise RC rahmen structures that were built since around 1970s are now required to rebuild. As a result, element technologies of explosive demolition for low-rise structures were applied to take advantage of technology in high-rise structures that performed application testing at Chungang Department demolition field in Daejeon city. It could judge elements technology establishment for high-rise structure demolition and field application and suggest the improvements when the problems occurred to develop High-rise building demolition techniques for method of protection a field test and the dust reduction test. The water cannon test was applied to reduce the dust site and the drilling tests are performed to select the best components for explosives demolition elements techniques of the reliability. This paper shows that we have the ability to remove a high-rise building using environmentally friendly safe and economical explosives demolition method. It would contribute to prevent a foreign company from entering the domestic market and should contribute to acquire competitiveness of domestic demolition industry.

      더보기

      참고문헌 (Reference)

      1 민형동, "대전 중앙데파트 발파해체 사례" 대한화약발파공학회 27 (27): 62-78, 2009

      2 Ahn, M.S, "Research for the selection of Blasting Demolition Method and the Analysis of Value Management in a Redevelopment Area" 39-46, 2010

      3 국토해양부, "RC 라멘조 발파해체 기술개발 연구, 첨단도시개발사업 중간보고서" 국토해양부 2007

      4 Hao, W, "Controlled Blasting Demolition of a High Building with Super-thin Wall Structure by Multi-direction Collapsing" APS Blasting 273-277, 2007

      1 민형동, "대전 중앙데파트 발파해체 사례" 대한화약발파공학회 27 (27): 62-78, 2009

      2 Ahn, M.S, "Research for the selection of Blasting Demolition Method and the Analysis of Value Management in a Redevelopment Area" 39-46, 2010

      3 국토해양부, "RC 라멘조 발파해체 기술개발 연구, 첨단도시개발사업 중간보고서" 국토해양부 2007

      4 Hao, W, "Controlled Blasting Demolition of a High Building with Super-thin Wall Structure by Multi-direction Collapsing" APS Blasting 273-277, 2007

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 계속평가 신청대상 (계속평가)
      2020-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2019-12-01 평가 등재후보 탈락 (계속평가)
      2018-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2016-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2013-01-01 평가 등재후보 탈락 (기타)
      2011-01-01 평가 등재후보 1차 FAIL (등재후보1차) KCI등재후보
      2009-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.19 0.19 0.14
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.13 0.16 0.509 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼