RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      상용 Force Sensitive Resistor(FSR)을 이용한 상완동맥에서의 인체 맥파 측정과 혈관의 긴장도, SDPTG Aging Index 분석 = An Analysis of Arterial Stiffness, SDPTG Aging Index through the Measurement of Physiological Pulse Signals from Brachial Artery using Commercial FSR

      한글로보기

      https://www.riss.kr/link?id=A106043077

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study conducted to confirm the possibility of pulse monitoring in the brachial artery through commercial FSR. The pulse from human body was measured by attaching FSR to the skin near the brachial artery and radial artery of the subject. For smoot...

      This study conducted to confirm the possibility of pulse monitoring in the brachial artery through commercial FSR. The pulse from human body was measured by attaching FSR to the skin near the brachial artery and radial artery of the subject. For smooth measurement, the cylindrical structure was designed and attached to the FSR, and pulse signals measured from the brachial artery and the radial artery were compared each other. Using the relationship between the systolic peak and the diastolic peak of acquired pulse signals, the stiffness index(SI), which is reported to be related to the stiffness of blood vessel, was calculated. Also, the SDPTG aging index, which is proportional to the age of the subject, was calculated through five peak points obtained by second differentiation of the pulse signals. Pulse rate measured in the brachial artery and radial artery was similar at about 96 bpm, and the pulse signals measured at the two sites was clearly distinguishable. In addition, the SI and SDPTG aging indices were 6.81 m/s and -1.966, respectively, which were close to the normal range. Therefore, this study confirmed the possibility of pulse monitoring in the brachial artery through commercial FSR proposed. Subsequently, ths next studies should be conducted to derive statistical estimates from pulse data measured in several subjects.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼