RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS SCIE

      Biomechanical Analysis of a Novel Wedge Locking Plate in a Porcine Tibial Model

      한글로보기

      https://www.riss.kr/link?id=A103555411

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background: The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. Methods: A uniform 8-mm OWHTO was performed in 12 porcine tibiae...

      Background: The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model.
      Methods: A uniform 8-mm OWHTO was performed in 12 porcine tibiae. Six of them were subsequently fixed with the plate without a wedge, whereas the other 6 were additionally reinforced with a metal wedge of 8 mm. Biomechanical properties (stiffness, displacement of the osteotomy gap, and failure load) were evaluated under axial load. The different modes of failure were also investigated.
      Results: The plate showed an axial stiffness of 2,457 ± 450 N/mm with a wedge and 1,969 ± 874 N/mm without a wedge. The maximum failure load was 5,380 ± 952 N with a wedge and 4,354 ± 607 N without a wedge. The plate with a wedge had a significantly greater failure load and significantly less displacement of medial gap at failure than that without a wedge (p = 0.041 and p = 0.002, respectively). The axial stiffness was not different between the two types of fixation. Most failures were caused by lateral cortex breakage and there was no implant failure.
      Conclusions: The novel wedge locking plate showed excellent biomechanical properties and an additional wedge provided significant improvement. This plate can be a good fixation method for OWHTO.

      더보기

      참고문헌 (Reference)

      1 Morrison JB, "The mechanics of the knee joint in relation to normal walking" 3 (3): 51-61, 1970

      2 Nelissen EM, "Stability of medial opening wedge high tibial osteotomy : a failure analysis" 34 (34): 217-223, 2010

      3 Jae Ho Yoo, "Rigid Stepped Plate for Internal Fixation for High Tibial Osteotomy" SLACK, Inc. 32 (32): 728-733, 2009

      4 Agneskirchner JD, "Primary stability of four different implants for opening wedge high tibial osteotomy" 14 (14): 291-300, 2006

      5 Floerkemeier S, "Outcome after high tibial open-wedge osteotomy : a retrospective evaluation of 533 patients" 21 (21): 170-180, 2013

      6 Stoffel K, "Open wedge high tibial osteotomy : biomechanical investigation of the modified Arthrex Osteotomy Plate(Puddu Plate)and the TomoFix Plate" 19 (19): 944-950, 2004

      7 Kuster MS, "Joint load considerations in total knee replacement" 79 (79): 109-113, 1997

      8 Schroter S, "High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate(Position HTO plate)without bone substitute" 27 (27): 644-652, 2011

      9 Saito T, "Five-to ten-year outcome following medial openingwedge high tibial osteotomy with rigid plate fixation in combination with an artificial bone substitute" 96 (96): 339-344, 2014

      10 Valkering KP, "Complications after tomofix medial opening wedge high tibial osteotomy" 22 (22): 218-225, 2009

      1 Morrison JB, "The mechanics of the knee joint in relation to normal walking" 3 (3): 51-61, 1970

      2 Nelissen EM, "Stability of medial opening wedge high tibial osteotomy : a failure analysis" 34 (34): 217-223, 2010

      3 Jae Ho Yoo, "Rigid Stepped Plate for Internal Fixation for High Tibial Osteotomy" SLACK, Inc. 32 (32): 728-733, 2009

      4 Agneskirchner JD, "Primary stability of four different implants for opening wedge high tibial osteotomy" 14 (14): 291-300, 2006

      5 Floerkemeier S, "Outcome after high tibial open-wedge osteotomy : a retrospective evaluation of 533 patients" 21 (21): 170-180, 2013

      6 Stoffel K, "Open wedge high tibial osteotomy : biomechanical investigation of the modified Arthrex Osteotomy Plate(Puddu Plate)and the TomoFix Plate" 19 (19): 944-950, 2004

      7 Kuster MS, "Joint load considerations in total knee replacement" 79 (79): 109-113, 1997

      8 Schroter S, "High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate(Position HTO plate)without bone substitute" 27 (27): 644-652, 2011

      9 Saito T, "Five-to ten-year outcome following medial openingwedge high tibial osteotomy with rigid plate fixation in combination with an artificial bone substitute" 96 (96): 339-344, 2014

      10 Valkering KP, "Complications after tomofix medial opening wedge high tibial osteotomy" 22 (22): 218-225, 2009

      11 Jung WH, "Comparative study of medial opening-wedge high tibial osteotomy using 2 different implants" 29 (29): 1063-1071, 2013

      12 Spahn G, "Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy" 21 (21): 272-278, 2006

      13 Tetsumura S, "Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction : a biomechanical study in porcine tibial bone" 11 (11): 278-282, 2006

      14 한승범, "Biomechanical Properties of a New Anatomical Locking Metal Block Plate for Opening Wedge High Tibial Osteotomy: Uniplane Osteotomy" 대한슬관절학회 26 (26): 155-161, 2014

      15 Andriacchi TP, "A study of lower-limb mechanics during stairclimbing" 62 (62): 749-757, 1980

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 선정 (해외등재 학술지 평가) KCI등재
      2020-12-01 평가 등재 탈락 (해외등재 학술지 평가)
      2020-04-14 학회명변경 영문명 : 미등록 -> The Korean Orthopaedic Association KCI등재
      2013-10-01 평가 등재학술지 선정 (기타) KCI등재
      2010-01-01 평가 SCOPUS 등재 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.06 0.06 0.07
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.07 0.1 0.346 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼