      A Novel Model of HVDC Hybrid-Type Superconducting Circuit Breaker and Its Performance Analysis for Limiting and Breaking DC Fault Currents

      한글로보기

      https://www.riss.kr/link?id=A107479411

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>The key obstacle in integrating high-voltage direct current (HVDC) point-to-point networks into meshed multiterminal HVDC networks (MTDC) is the absence of dc circuit breakers (DCCBs), which can timely and reliably isolate the faulty HVDC net...

      <P>The key obstacle in integrating high-voltage direct current (HVDC) point-to-point networks into meshed multiterminal HVDC networks (MTDC) is the absence of dc circuit breakers (DCCBs), which can timely and reliably isolate the faulty HVDC network from the MTDC. In this paper, a novel hybrid-type superconducting DCCB model (SDCCB) is proposed. The SDCCB has a superconducting fault current limiter (SFCL) located in the main line, to limit the fault current until the final trip signal to the SDCCB is given. After the trip signal, insulated-gate bipolar transistor (IGBT) switches located in the main line will commutate the fault current into a parallel line, where dc current is forced to zero by combination of IGBTs and surge arresters. DC fault current behavior in MTDC and fundamental requirements of DCCB for MTDC were described, followed by an explanation of the working principles of the SDCCB. To prove the viability of the SDCCB, a simulation analysis demonstrating SDCCB current interruption performance was done for changing the intensity of dc fault current. It was observed that the passive current limiting by SFCL caused significant reduction in fault current interruption stress for SDCCB. Furthermore, fundamental design requirements for SFCL, including the effect of SFCL quenching impedance on SFCL voltage rating and energy dissipation capacity, were investigated. Finally, advantages and limitations of the SDCCB were highlighted.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼