carbon neutrality, “ZEB certification” and “mandatory installation of renewable energy systems” have ensured the inevitable introduction of renewable energy along with insulation and high-efficiency equipment systems for a reduction in buildin...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A108455047
2022
Korean
553
학술저널
1128-1131(4쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
carbon neutrality, “ZEB certification” and “mandatory installation of renewable energy systems” have ensured the inevitable introduction of renewable energy along with insulation and high-efficiency equipment systems for a reduction in buildin...
carbon neutrality, “ZEB certification” and “mandatory installation of renewable energy systems” have ensured the inevitable introduction of renewable energy along with insulation and high-efficiency equipment systems for a reduction in building energy. Meanwhile, studies have been conducted on the use of various alternative renewable energy sources, such as sunlight, solar heat, ground heat, and fuel cells; however, it remains extremely difficult to apply them to the building sector, except for sunlight and solar heat energies, owing to regional restrictions. In the case of the geothermal source heat pump system, there is a problem of lowering heating performance due to a drop in underground temperature due to an imbalance in heating and cooling loads in domestic climate conditions. Therefore, the solar power system was selected as an auxiliary heat source to supplement the insufficient heat source during the heating period, and previous studies confirmed that the power consumption of the heat pump and the underground heat exchanger circulation pump can be reduced by improving the thermal environment of the heat source. However, since the solar power system requires a lot of initial investment costs, it is important to produce the optimal effect with the geothermal power heat pump system through efficient design and operation. Therefore, in this study, an analysis model was established based on the relational expression of the elements constituting the system for the optimal design and operation of the geothermal source heat pump system linked to solar sources, and a numerical analysis tool was prepared. The optimal design and operation conditions were derived through various parameter studies by analyzing the effect of system switching temperature from geothermal source to solar source through various numerical experiments. As a result of applying it to the target building, it was shown that it was possible to reduce power consumption by 25% compared to the case of using only a geothermal source.
목차 (Table of Contents)
공동주택 지역난방시스템의 운전 시그니처 도출을 위한 클러스터링 자동화 방법
중소규모 공공건축물의 제로에너지빌딩 구현 방안에 관한 연구
국내 그린리모델링 현장 사례분석을 통한 레트로 커미셔닝(RCx) 적용의 중요성 검토