In this paper, the performance of a domestic Kim-Chi refrigerator is predicted by using a calculation<br/> model & experiment. The objectives of this study are to find out the best design points of a refrigeration<br/> system and calculate...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A75897333
2003
Korean
550
학술저널
769-774(6쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
In this paper, the performance of a domestic Kim-Chi refrigerator is predicted by using a calculation<br/> model & experiment. The objectives of this study are to find out the best design points of a refrigeration<br/> system and calculate...
In this paper, the performance of a domestic Kim-Chi refrigerator is predicted by using a calculation<br/>
model & experiment. The objectives of this study are to find out the best design points of a refrigeration<br/>
system and calculate an adiabatic characteristic to change outdoor temperature. The best design points such as<br/>
refrigerant charge and capillary length were experimentally investigated. And the calculation model is<br/>
conducted as a function of calculation parameters and outdoor temperature. According to this study results,<br/>
the best design points of a refrigeration system are each 95g of a refrigerant charge and 3500/3500mm of<br/>
capillary lengths. And the power consumption is 13.578 Kwh/month. And a part of the worst heat loss is a<br/>
front side of a domestic Kim-Chi refrigerator body.