RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      ThermoPoD: A reliability study on active infrared thermography for the inspection of composite material

      한글로보기

      https://www.riss.kr/link?id=A103789005

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, a Probability of Detection (PoD) experimental study was carried out in the framework of a Belgian-Quebec/Canada collaborative research project called ThermoPoD. Experiments were implemented on a Carbon Fiber Reinforced Plastic (CFRP) sp...

      In this study, a Probability of Detection (PoD) experimental study was carried out in the framework of a Belgian-Quebec/Canada collaborative research project called ThermoPoD. Experiments were implemented on a Carbon Fiber Reinforced Plastic (CFRP) specimen with embedded material simulating delamination. For active infrared thermography, different heating sources (optical or ultrasound),heating forms (pulsed or lock-in), and data processing methods, such as Fourier Transform, Thermal Signal Reconstruction, Wavelet Transform, Differential Absolute Contrast, and Principal Component Thermography are of interest. In the present study, the effects of various data processing methods on PoD curves are compared.

      더보기

      참고문헌 (Reference)

      1 C. Ibarra-Castanedo, "Thermographic nondestructive evaluation: overview of recent progress" XXV : 450-459, 2003

      2 X. P. V. Maldague, "Theory and practice of infrared technology for nondestructive testing" Wiley 2001

      3 S. W. Floyd, "The Calculation and Use of Confidence Bounds in POD Models" 26 : 1791-1798, 2007

      4 S. M. Shepard, "Synthetic processing of pulsed thermographic data for inspection of turbine components" 43 : 587-589, 2001

      5 A. J. Hodge, "Probability of detection study on impact damage to honeycomb composite structure using thermographic inspection" 2008

      6 P. Servais, "Probability of detection for in field thermal non destructive testing of aircraft composite structures (ABSTRACT)" 2010

      7 N. Rajic, "Principal component thermography for flaw contrast enhancement and flaw depth characterization in composite structures" 58 : 521-528, 2002

      8 US Air Force Aeronautical Systems Center, "Non- Destructive Evaluation System Reliability Assessment, Military Handbook"

      9 M. Pilla, "New absolute contrast for pulsed thermography" 2002

      10 S. Shepard, "Depth and spatial resolution enhancement using thermographic signal reconstruction" 279-284, 2002

      1 C. Ibarra-Castanedo, "Thermographic nondestructive evaluation: overview of recent progress" XXV : 450-459, 2003

      2 X. P. V. Maldague, "Theory and practice of infrared technology for nondestructive testing" Wiley 2001

      3 S. W. Floyd, "The Calculation and Use of Confidence Bounds in POD Models" 26 : 1791-1798, 2007

      4 S. M. Shepard, "Synthetic processing of pulsed thermographic data for inspection of turbine components" 43 : 587-589, 2001

      5 A. J. Hodge, "Probability of detection study on impact damage to honeycomb composite structure using thermographic inspection" 2008

      6 P. Servais, "Probability of detection for in field thermal non destructive testing of aircraft composite structures (ABSTRACT)" 2010

      7 N. Rajic, "Principal component thermography for flaw contrast enhancement and flaw depth characterization in composite structures" 58 : 521-528, 2002

      8 US Air Force Aeronautical Systems Center, "Non- Destructive Evaluation System Reliability Assessment, Military Handbook"

      9 M. Pilla, "New absolute contrast for pulsed thermography" 2002

      10 S. Shepard, "Depth and spatial resolution enhancement using thermographic signal reconstruction" 279-284, 2002

      11 H. D. Benítez, "Definition of a new thermal contrast and pulse correction for defect quantification in pulsed thermography" 51 : 160-167, 2008

      12 Y. Guo, "Comparison of detection capability for acoustic thermography, visual inspection and fluorescent penetrant inspection on gas turbine components, Review of Quantitative Nondestructive Evaluation" 28 : 1848-1854, 2009

      13 J. DiMambro, "Chapter 15, Quantitative evaluation of emerging infrared thermography technologies for aerospace applications, In Ultrasonic and Advanced Methods for Nondestructive Testing and Material Characterization" 349-367, 2006

      14 F. R. Galmiche, "Application of wavelet transform for the nondestructive evaluation of materials by pulsed phase thermography" Université Laval 2005

      15 G. Kaiser, "A friendly guide to wavelets"

      16 J. DiMambro, "A composite honeycomb probability of detection (POD) experiment using an uncooled infrared camera for pulsed thermography" 2006

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-11-05 학술지명변경 한글명 : 대한기계학회 영문 논문집 -> Journal of Mechanical Science and Technology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-19 학술지명변경 한글명 : KSME International Journal -> 대한기계학회 영문 논문집
      외국어명 : KSME International Journal -> Journal of Mechanical Science and Technology
      KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1998-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.04 0.51 0.84
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.74 0.66 0.369 0.12
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼