      힘 센서와 MSP430 기반 수면 중 움직임 측정 시스템 개발

      한글로보기

      https://www.riss.kr/link?id=A106472268

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The purpose of this study is to develop a system that can measure the movement of the human body during sleep in a way that does not constrain the body. In this study, a measurement system was implemented using a strip-type force sensor placed on a ma...

      The purpose of this study is to develop a system that can measure the movement of the human body during sleep in a way that does not constrain the body. In this study, a measurement system was implemented using a strip-type force sensor placed on a mattress, under the user"s body, and an MSP430G2553 ultra-low-power processor. The strip sensor was fabricated using Polyvinylidene fluoride film. The signal obtained from the sensor was pre-processed and amplified through the developed analog front-end, and then converted to a digital signal through the ADC of MSP430. The MSP430 uses a timer interrupt and an ADC interrupt to minimize CPU operation time for low power operation. Through the comparison with the reference instrument, it was confirmed that the developed system can track the tossing, turning and breathing signals during sleep.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 측정 시스템 설계
      • 3. 결과
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 측정 시스템 설계
      • 3. 결과
      • 4. 결론
      • Reference
      더보기

      참고문헌 (Reference)

      1 S. H. Hwang, "Unconstrained sleep apnea monitoring using polyvinylidene fluoride film-based sensor" 61 (61): 2125-2134, 2014

      2 F. Touati, "U-healthcare system : State-ofthe-art review and challenges" 37 (37): 9949-, 2013

      3 "SleepNumber"

      4 Texas Instruments, "SLAU144I: MSP430x2xx Family: User’s Guide"

      5 N. Bu, "Monitoring of respiration and heartbeat during sleep using a flexible piezoelectric film sensor and empirical mode decomposition" IEEE 1362-1366, 2007

      6 A. Beda, "Low frequency heart rate variability is related to the breath to breath variability in the respiratory pattern" 51 (51): 197-205, 2014

      7 R. Seepold, "Home Hospital e-Health Centers for Barrier-Free and Cross-Border Telemedicine" Springer 307-316, 2019

      8 A. Fernandez, "Getting startedwith the MSP430 launchpad" 2013

      9 "EarlySense"

      10 F. Wang, "Development of a PVDF piezopolymer sensor for unconstrained in-sleep cardiorespiratory monitoring" 14 (14): 185-190, 2003

      1 S. H. Hwang, "Unconstrained sleep apnea monitoring using polyvinylidene fluoride film-based sensor" 61 (61): 2125-2134, 2014

      2 F. Touati, "U-healthcare system : State-ofthe-art review and challenges" 37 (37): 9949-, 2013

      3 "SleepNumber"

      4 Texas Instruments, "SLAU144I: MSP430x2xx Family: User’s Guide"

      5 N. Bu, "Monitoring of respiration and heartbeat during sleep using a flexible piezoelectric film sensor and empirical mode decomposition" IEEE 1362-1366, 2007

      6 A. Beda, "Low frequency heart rate variability is related to the breath to breath variability in the respiratory pattern" 51 (51): 197-205, 2014

      7 R. Seepold, "Home Hospital e-Health Centers for Barrier-Free and Cross-Border Telemedicine" Springer 307-316, 2019

      8 A. Fernandez, "Getting startedwith the MSP430 launchpad" 2013

      9 "EarlySense"

      10 F. Wang, "Development of a PVDF piezopolymer sensor for unconstrained in-sleep cardiorespiratory monitoring" 14 (14): 185-190, 2003

      11 Y. He, "Assess Novelty of an Invention Using the central-extreme novelty matrix: a case study of juvo labs’s fibre-optic sensor mat" University of Bath 134-141, 2018

      12 J. M. Perez-Macias, "36th Annual InternationalConference of the IEEE Engineering in Medicine and Biology Society, IEEE, pp" IEEE 4979-4982, 2014

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 학술지 통합 (기타) KCI등재
      2001-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.27 0.27 0.24
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.19 0.366 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼