RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價 = Dose Distribution of Rectum and Bladder in Intracavitary Irradiation

      한글로보기

      https://www.riss.kr/link?id=A105782929

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The s...

      The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy.
      The complications of pelvic organ are known to be directly related to radiation dose and physical parameters.
      The simulation radiogram and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct 1983, were critically analized.
      The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system.
      The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer.
      Followings were summary of study results;
      1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as 4~7 cm width and high dose rate system showed as 5~6 cm.
      2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position 64.6%, left deviation 19/2% and right deviation 16.2%.
      3. In longitudinal angulation of tandem to body axis, the mid position was 11.8% and anterior angulation 88.2% in low dose rate system but in high dose rate system, anterior angulation was 98.5%.
      4. Down ward displacement of ovoids below external os was only 3% in low dose rate system and 66.7% in high dose rate system.
      5. Inradiation source arrangement, the most activites of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system.
      6. In low and high dose rate system, the total doses and TDF were 80, 70 Gy and 141, 123, including 40 Gy external irradiation.
      7. The doses and TDF in interesting points Co, B, sere 98, 47 Gy and 230, 73 in high dose rate system but in low dose rate system, 125, 52 Gy and 262, 75 respectively.
      8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy and 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, 30% and 18, 23% respectively.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼