Purpose : The purpose of this study is to describe the surgical technique of ACL reconstruction with the flexible reamer and evaluate the clinical results of this method. Materials and Methods : Twenty four patients who followed for 12 months were inc...
Purpose : The purpose of this study is to describe the surgical technique of ACL reconstruction with the flexible reamer and evaluate the clinical results of this method. Materials and Methods : Twenty four patients who followed for 12 months were included. The results were evaluated by Lachman test, KT-2000 arthrometer, Lysholm score, and postoperative roentgenogram of the knee. Results : The range of motion of the affected knee was acceptable except one case(10 to 90 degree) and at the last follow up, two cases were positive in Lachman test. Mean Lysholm knee scoring scale was 63.7 point preoperatively and 91.4 point at the last follow up. The results of KT-2000 arthrometer was 6.6mm preoperatively and 1.5mm at the last follow up. In operative time, there were decrease of mean 13.5 minute than ACL reconstruction without the flexible reamer, Conclusion : ACL reconstruction with the flexible reamer achieves the ideal isometric point of tibia and femur with no difficulty, proper notchplasty preventing from the impingement, and lessens the operative time.