RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCOPUS SCIE

    Detection of PCB77 by Indirect Competitive Enzyme-linked Immunosorbent Assay in Sea Sediment Samples

    한글로보기

    https://www.riss.kr/link?id=A103886919

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    3,3',4,4'-Tetrachlorobiphenyl (IUPAC PCB77) is one of seven indicative polychlorinated biphenyls (PCBs) in the surface sediments. The current study presents a novel polyclonal antibody for the determination of the PCB77 using indirect competitive enzyme-linked immunosorbent assay. Under optimum conditions, PCB77 was determined within the concentration range of 0.01-100 μg L–1, with a detection limit of 0.057 μg L–1. The assays were tested for their cross-reactivity profiles using 3 selected congeners and 4 Aroclor products. The assays were highly specific for coplanar PCB congeners, but less specific for Aroclor1248. The spiked recoveries from five sediment samples were 86%-114% for PCB77 from ELISA, which were satisfactory. The current study demonstrated that the developed antiserum and immunoassay procedure can be used to detect PCB77 in environmental samples. The results of the sediment analysis were confirmed by conventional GC/ ECD.
    번역하기

    3,3',4,4'-Tetrachlorobiphenyl (IUPAC PCB77) is one of seven indicative polychlorinated biphenyls (PCBs) in the surface sediments. The current study presents a novel polyclonal antibody for the determination of the PCB77 using indirect competitive enzy...

    3,3',4,4'-Tetrachlorobiphenyl (IUPAC PCB77) is one of seven indicative polychlorinated biphenyls (PCBs) in the surface sediments. The current study presents a novel polyclonal antibody for the determination of the PCB77 using indirect competitive enzyme-linked immunosorbent assay. Under optimum conditions, PCB77 was determined within the concentration range of 0.01-100 μg L–1, with a detection limit of 0.057 μg L–1. The assays were tested for their cross-reactivity profiles using 3 selected congeners and 4 Aroclor products. The assays were highly specific for coplanar PCB congeners, but less specific for Aroclor1248. The spiked recoveries from five sediment samples were 86%-114% for PCB77 from ELISA, which were satisfactory. The current study demonstrated that the developed antiserum and immunoassay procedure can be used to detect PCB77 in environmental samples. The results of the sediment analysis were confirmed by conventional GC/ ECD.

    더보기

    참고문헌 (Reference)

    1 Kannan, K., 131 : 425-, 2004

    2 Aydin, M. E., 577 : 32-, 2006

    3 Gilbert, R, 59 : 275-, 2004

    4 Bonefeld-Jorgensen, E. C., 158 : 141-, 2001

    5 Sager, D. B, 38 : 946-, 1987

    6 Durand, B., 70 : 689-, 2008

    7 Yang, F. X., 73 : 133-, 2008

    8 Cachada, A, 157 : 511-, 2009

    9 Cao, L. L., 409 : 2997-, 2001

    10 Jerry, W. A., 16 : 369-, 1991

    1 Kannan, K., 131 : 425-, 2004

    2 Aydin, M. E., 577 : 32-, 2006

    3 Gilbert, R, 59 : 275-, 2004

    4 Bonefeld-Jorgensen, E. C., 158 : 141-, 2001

    5 Sager, D. B, 38 : 946-, 1987

    6 Durand, B., 70 : 689-, 2008

    7 Yang, F. X., 73 : 133-, 2008

    8 Cachada, A, 157 : 511-, 2009

    9 Cao, L. L., 409 : 2997-, 2001

    10 Jerry, W. A., 16 : 369-, 1991

    11 Na, Y. C., 73 : S7-, 2008

    12 Kotaro, M, 27 : 421-, 2011

    13 Ayato, K., 22 : 1393-, 2006

    14 Tomoaki, T., 65 (65): 467-, 2006

    15 Chiu, Y. W., 73 : 5477-, 2001

    16 Shimomura, M, 434 : 223-, 2001

    17 Javier, C. J, 13 : 894-, 2011

    18 Glass, T. R., 517 : 161-, 2004

    19 Carlo, M. D, 336 : 167-, 1996

    20 Franek, M., 444 : 131-, 2001

    21 Chuang, C. J., 376 : 67-, 1998

    22 Kania-Korwel, I., 56 : 735-, 2004

    23 Nuria, P. N., 594 : 211-, 2007

    24 Zhang, M. C., 386 : 1401-, 2006

    25 Li, S., 144 : 434-, 2006

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2008-01-01 등재 SCI 등재 (기타) KCI등재
    2006-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2004-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2001-07-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    1998-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.58 0.11 0.38
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.28 0.23 0.213 0.04
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼