RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases = Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion. Methods: In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? Results: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems. Conclusion: In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting. [ J Trauma Inj 2016; 29: 129-138 ]
      번역하기

      Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixati...

      Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion. Methods: In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? Results: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems. Conclusion: In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting. [ J Trauma Inj 2016; 29: 129-138 ]

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼