<P>The divertor Infrared television (IR TV) system for monitoring the temperature of a divertor and localized hot spots will be installed on the upper port of the N-port in the Korea Superconducting Tokamak Advanced Research (KSTAR). The cassett...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107643833
2014
-
SCI,SCIE,SCOPUS
학술저널
11409
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>The divertor Infrared television (IR TV) system for monitoring the temperature of a divertor and localized hot spots will be installed on the upper port of the N-port in the Korea Superconducting Tokamak Advanced Research (KSTAR). The cassett...
<P>The divertor Infrared television (IR TV) system for monitoring the temperature of a divertor and localized hot spots will be installed on the upper port of the N-port in the Korea Superconducting Tokamak Advanced Research (KSTAR). The cassette of KSTAR makes a periscope inevitable for the divertor IR TV. In this article, 4 design concepts for the periscope were examined, and the design based on Keplerian was shown to have better stabilities in alignment and the vibration. The final optics design based on an f-theta lens, Keplerian, and telecentric lens was derived.</P>
Note: Optical receiver system for 152-channel magnetoencephalography (3 pages)
Quasi 3D ECE imaging system for study of MHD instabilities in KSTAR.
High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range (5 pages)