RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      눈물의 생체 분자 추출을 위한 미세유관이 탑재된 유연한 콘택트 렌즈 = Micro-channel Embedded Soft Contact Lens for Tear Biomolecule Sampling

      한글로보기

      https://www.riss.kr/link?id=A102900807

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabete...

      Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabetes. However, currently existing methods for collecting and extracting tear from the human eye causes inconsistencies in the biomolecule concentrations of the tear sample due to the irritating nature of the process. In response, we designed and fabricated a microfluidic system embedded soft contact-lens for the purpose of tear sampling. The lens was then tested with artificial tear for its tear sampling capability, and found to be able to find concentration equilibrium within 50 minutes. Additionally, simulation was carried out to further optimize the design so that tear sampling rate matched the natural tear turn-over rate of 1 microliter per minute.

      더보기

      참고문헌 (Reference)

      1 D. Pieragostino, "Unraveling the molecular repertoire of tears as a source of biomarkers : Beyond ocular diseases" 9 (9): 169-186, 2015

      2 J. D. Lane, "Tear Glucose Dynamics in Diabetes Mellitus" 31 (31): 895-901, 2006

      3 J. T. Baca, "Tear Glucose Analysis for the Noninvasive Detection and Monitoring of Diabetes Mellitus" 5 (5): 280-293, 2007

      4 A. Lebrecht, "Surface-enhanced Laser Desorption/Ionisation Timeof-flight Mass Spectrometry to Detect Breast Cancer Markers in Tears and serum" 6 (6): 75-83, 2008

      5 J. Zhang, "Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose" 5 (5): 166-172, 2011

      6 Verpoorte E, "Microfluidic chips for clinical and forensic analysis" 23 (23): 677-712, 2002

      7 K. N. Han, "Microfluidic Chips for Immunoassays" 6 : 119-141, 2013

      8 R. K. Hobbie, "Intermediate Physics for Medicine and Biology" Springer-Verlag 2007

      9 C. Salvisberg, "Exploring the human tear fluid : Discovery of new biomarkers in multiple sclerosis" 8 (8): 185-194, 2014

      10 X. Feng, "Advances in Coupling Microfluidic Chips to Mass Spectrometry" 34 (34): 535-557, 2015

      1 D. Pieragostino, "Unraveling the molecular repertoire of tears as a source of biomarkers : Beyond ocular diseases" 9 (9): 169-186, 2015

      2 J. D. Lane, "Tear Glucose Dynamics in Diabetes Mellitus" 31 (31): 895-901, 2006

      3 J. T. Baca, "Tear Glucose Analysis for the Noninvasive Detection and Monitoring of Diabetes Mellitus" 5 (5): 280-293, 2007

      4 A. Lebrecht, "Surface-enhanced Laser Desorption/Ionisation Timeof-flight Mass Spectrometry to Detect Breast Cancer Markers in Tears and serum" 6 (6): 75-83, 2008

      5 J. Zhang, "Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose" 5 (5): 166-172, 2011

      6 Verpoorte E, "Microfluidic chips for clinical and forensic analysis" 23 (23): 677-712, 2002

      7 K. N. Han, "Microfluidic Chips for Immunoassays" 6 : 119-141, 2013

      8 R. K. Hobbie, "Intermediate Physics for Medicine and Biology" Springer-Verlag 2007

      9 C. Salvisberg, "Exploring the human tear fluid : Discovery of new biomarkers in multiple sclerosis" 8 (8): 185-194, 2014

      10 X. Feng, "Advances in Coupling Microfluidic Chips to Mass Spectrometry" 34 (34): 535-557, 2015

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2017-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-10-06 학술지명변경 외국어명 : 미등록 -> Joural of Biomedical Engineering Research KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2002-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.08 0.08 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.09 0.307 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼