      Digital Fluoroscopy System에서 촬영조건의 변화에 따른 DICOM Image의 Histogram 변화와 JPEG 압축률의 변화 분석 = Comparison of Change of Histogram and JPEG Compression Rate of DICOM Image by Exposure Condition in Digital Fluoroscopy

      한글로보기

      https://www.riss.kr/link?id=A103540112

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      To find the proper exposure condition in digital fluoroscopic system, it is compared the change of histogram and JPEG compression rate of DICOM Image according to exposure condition. Digital fluoroscopic system was Philips easy diagnost with under tab...

      To find the proper exposure condition in digital fluoroscopic system, it is compared the change of histogram and JPEG compression rate of DICOM Image according to exposure condition. Digital fluoroscopic system was Philips easy diagnost with under table tube. BaSO4 of 220% w/v phantom to the size 18×22.5 ×0.2㎝ and two polyethylene phantom to 35.5×35.6×7㎝ were used for this study. A standard value (90㎸, 1.93mAs, 9.55㎳, 202㎃) was obtained by Automatic exposure Controler (AEC) for comparing with manual exposure condition. The test were done by changing 40, 50, 60, 70, 81, 90, 102, 109, 117㎸ with mAs fixed, and 63, 80, 100, 125, 160, 200, 250, 320, 400㎃ with ㎸ fixed, and 3.2, 4, 5, 6.2, 8, 10, 12.5 16, 20㎳ with mA and ㎸ fixed. Distribution of histogram of DICOM Image in the case of mAs fixed shifted from left toward right according to ㎸ increment gradually. Distribution of histogram in the case of ㎸ fixed also shifted from left toward right according to mAs increment gradually. When mA and ㎸ was fixed, the histogram was not a significant change according to change ㎳. JPEG compression rate was the lowest at standard value including 90㎸, 1.93mAs, 9.55㎳,and 202㎃ obtained by AEC. The exposure condition is better by AEC than by manual setting up. Analysis of histogram of DICOM Image can be used as a method for quality control of AEC.

      더보기

      목차 (Table of Contents)

      • Abstact
      • Ⅰ. 서론
      • Ⅱ. 대상 및 방법
      • Ⅲ. 결과
      • Ⅳ. 고찰
      • Abstact
      • Ⅰ. 서론
      • Ⅱ. 대상 및 방법
      • Ⅲ. 결과
      • Ⅳ. 고찰
      • Ⅴ. 결론
      • 참고문헌
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼