RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Current Status of Passive Solar Building Applications in the Republic of Korea

        Auh, Paul Chung-Moo The Korean Solar Energy Society 1987 한국태양에너지학회 논문집 Vol.7 No.2

        In the past few years, the subject of passive heating has been the major area of our concern due to the specific climate conditions prevailing in our region. More recently, however, other important issues such as retrofitting, passive cooling, optimized integration of conservation and passive solar, and daylighting have emerged as the areas of frequent discussions. KIER, the sole R&D organization in solar energy technologies, has accomplished significant results in passive building designs and actual demonstrations of experimental passive buildings. As a result of such endeavor by KIER, the passive solar buildings have been very well received by the Korean public. The current number of passive solar buildings in Korea is well over 1,600 (as of Dec. 1986). In this paper, broad aspects of the present status of passive solar technology utilization in Korea are presented.

      • KCI등재

        Energy Auditing Using a Building Energy Simulation Program BLDSYM

        Lee, E.J.,Yoon, J.H.,Kang, Y.H.,Jeon, H.S. The Korean Solar Energy Society 1995 한국태양에너지학회 논문집 Vol.15 No.3

        The objectives of this study are to introduce the energy simulation program BLDSYM, to verify the approach, and to demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK, USA has been introduced as a base case simulation. Air-side variable air volume(VAV) and water-side variable flow hydronic(VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30% of energy savings could be obtained with the optimum variable flow system.

      • KCI등재

        Design, Fabrication and Performance Analysis of Fiber Optic Concentrators for Daylighting

        한현주,김정태,Han, Hyun-Joo,Kim, Jeong-Tai The Korean Solar Energy Society 2007 한국태양에너지학회 논문집 Vol.27 No.4

        자연광의 이용은 큰 어려움 없이 지속 가능한 에너지 기술을 구현할 수 있는 방안으로 고려되고 있다. 여러 개의 작은 반사경을 적용한 태양 추적식 자연채광 시스템은 비교적 단순한 메카니즘을 적용하여 그 성능과 효용성의 극대화를 꾀할 수 있으며, 또한 그 제작, 설치 작동 그리고 활용성에서 상당한 이점이 있다. 본 연구에서는 작은 mini-dish형 반사경(직경<30cm 이하)을 이용한 화이버 광학 집광기의 설계, 제작 및 작동 특성에 대하여 소개하고, 아울러 광추적 프로그램인 Photopia를 이용하여 그 성능에 대한 시뮬레이션을 수행하였다. 주요 구성 요소에서의 광추적에 의한 시뮬레이션 결과치는 실제 시스템의 설계 및 성능 예측에 중요한 기술적 데이터를 제공하며, 특히 실측이 곤란한 측정 면에서의 빛의 경로 해석에 유용하게 적용될 수 있다.

      • KCI등재

        Shadow Analysis: A Visual Analysis Model for the Perfromance of External Shading Devices

        Won, Jin-Tae The Korean Solar Energy Society 1993 한국태양에너지학회 논문집 Vol.13 No.2

        건물의 외부에 차양을 설치하는 것은 건물이 갖는 냉방부하를 줄일 수 있는 중요한 요인이 된다. 외부차양의 효율성은 차양의 형태, 크기, 태양의 경로, 건물의 방향등과 같은 요소에 의해 결정 지어진다. 그러나, 이러한 요소들이 서로 동적으로 상호 관련 되어 있기 때문에 외부차양에 의한 그림자 투영은 예측하기 힘들고, 따라서 냉방부하가 얼마만큼 감소되는지는 더욱더 예측이 어려워진다. 이 논문은 디자이너가 직접 외부차양을 컴퓨터 그래픽으로 디자인 함과 동시에 그림자 투영을 시각화 할 수 있는 프로그램 개발을 위한 연구이다.

      • KCI등재

        Study on the Relationships between Single Bubble Growth Behavior and Bubble Shape Assumption in Pool and low-He Flow Boiling

        김정배,Kim, Jeong-Bae The Korean Solar Energy Society 2009 한국태양에너지학회 논문집 Vol.29 No.3

        포화상태 핵비등과 저 Re수의 흐름비등에서 얻어진 실험결과를 바탕으로 하여, 기포가 성장하는 동안의 등가 기포 직경과 열전단율의 거동에 대한 기포 형상 가정의 효과를 제시하기 위한 해석적인 연구를 수행하였다. 이러한 목적을 달성하기 위하여, 등가 기포 반경이 기포가 성장하는 동안 촬영된 기포의 이미지로부터 얻어질 수 있는 형상 가정을 이용하여 계산되었다. 그리고 열전달율을 포화상태 핵비등 동안 미세크기의 히터와 휘스톤브리지 회로를 이용하여 측정하였다. 그리고, 기포 형상 가정의 효과를 실험결과와 비교하였고, 이를 통해 단일 기포의 성장 거동을 분석하기 위한 기포 형상 가정이 매우 중요함을 보였다.

      • KCI등재

        A Study on Water Balance in Stationary Load Proton Exchange Membrane(PEM) Fuel Cell Power Generator

        아궁 박타아르,오후규,윤정인,김영복,최광환,Bakhtiar, Agung,Oh, Hoo-Kyu,Yoon, Jung-In,Kim, Young-Bok,Choi, Kwang-Hwan The Korean Solar Energy Society 2011 한국태양에너지학회 논문집 Vol.31 No.4

        일반적으로 PEM 연료전지에서는 수분 균형이 시스템의 효율에 결정적으로 영향을 미치기 때문에, 이에 대한 균형(balance)을 잡는 것이 매우 중요하다. 특히, 촉매 층에서 물이 넘치는 익수현상(flooding)이나 건조현상(drying)이 발생하게 되면 연료전지의 효율이 급격하게 저하하므로, 항상 수분의 균형이 잡히도록 시스템을 제어하는 것이 일반적이다. 이 때,수분의 익수현상이나 건조현상은 PEM 연료전지의 용량과 주위의 환경, 즉 온도와 습도에 많은 영향을 받게 된다. 금번 논문에서는 가정용 규모인 3kW급에서 10kW급까지의 PEM 연료전지를 설치하였을 때, 주위의 환경(온도와 습도)이 수분 이동에 어떠한 영향을 미치는 지를 시간에 따라서 시뮬레이션(simulation)한 결과를 보여주고 있다. 결과에서 유입공기의 온도가 $50^{\circ}C$ 이하일 경우, 고정부하가 5kW급 이하이면 대부분이 건조현상이 발생하였으나, 고정부하가 6kW급 이상이 되면 익수현상이 운전시간이 20분 이내에서 발생하였다. 또한 고정부하를 최고 10kW급까지 올린 경우, 유입공기의 온도가 $50^{\circ}C$까지는 익수현상이 발생하였으나 $60^{\circ}C$ 이상인 경우에는 거의 건조현상이 발생함을 알 수 있었다.

      • KCI등재

        Image Capturing of Dispersed Phases in DCHXs by Electric Tomography

        Chun, Won-Gee,Kim, Min-Chan,Lee, Heon-Ju,Kang, Yong-Heack,Kwon, Hyok-Bo The Korean Solar Energy Society 2001 한국태양에너지학회 논문집 Vol.21 No.2

        This paper introduces the physical phenomena involved in Direct Contact Heat Exchangers (DCHXs) and also investigates the possibility of applying of EIT(Electrical Impedance Tomography) technique for capturing the images of dispersed phases as they stream through a stagnant body of water. A number of cases are studied where two dimensional cross-sectional static images are given for fictitious and actual masses present in a column of water(saline solution). In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density different(lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the elucidation of complicated flow field where the dispersed phase fluid tends to change its shape and size constantly during its journey through the other phase(water). This paper presents a number of results with different types of dispersed phases that are immiscible with water. The EIT technique has been employed in this context to test its applicability in capturing the dynamic images of dispersed phases. It shows static images of dispersed phases where dynamic images could be obtained by simply extending the algorithms and strategies employed in the present analysis.

      • KCI등재

        Review of Entrainment and Interfacial Stability in Thermosyphons and Capillary-Driven Heat Pipes

        Kim, B.H.,Kim, C.J. The Korean Solar Energy Society 1998 한국태양에너지학회 논문집 Vol.18 No.3

        Entrainment in thermosyphons and heat pipes was characterized in view of the interfacial stability associated with the critical Weber number and the entrainment limit at the onset of liquid entrainment from the liquid or wicked interface. Both literature review and theoretical analysis on the entrainment models were peformed in order to evaluate accuracy of the predicted value. For this purpose, the models were categorized in two groups according to their entrainment mechanism and interfacial configurations, i.e., the wave-induced entrainment and the shear-induced entrainment, respectively. Thus, the twelve models(five models for the wave-induced entrainment and seven for the shear induced entrainment) were examined to obtain individual trends and their discrepancies from the general tendency of the overall models. As a result, the critical Weber numbers and entrainment limits were calculated and represented as a function of vapor temperature for the chosen characteristic dimensions of the interface.

      • KCI등재

        Advanced Silicon Solar Cell Structures for Space Applications

        Lee, S.H.,Kim, D.S. The Korean Solar Energy Society 1997 한국태양에너지학회 논문집 Vol.17 No.2

        This paper reviews the advanced solar cell structures used in space. These are the structures which incorporate the back surface field and reflectors with very shallow and lightly doped emitters. Their use in space has shown that the thinner cells are more resistive to radiation damage than the thicker ones. It has been found that the charged particles affect both the surface and bulk of the cells used in space. This causes degradation in the output power, which in effect, can be explained by the degrading diffusion length of the cells. The PERL cells showed higher BOL(beginning of life) efficiency and almost the same EOL(end of life) efficiency as structures with wrap-around contact configuration fabricated on 10 ${\Omega}cm$ resistivity substrates. This observation lead to a conclusion that, the space cells do not necessarily need to have very high BOL efficiency except in specific missions which require such.

      • KCI등재

        Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples

        아닐 쿠마르,김만회,Kumar, Anil,Kim, Man-Hoe The Korean Solar Energy Society 2015 한국태양에너지학회 논문집 Vol.35 No.4

        This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼