RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSSCIEKCI등재

        Three-Dimensional Printing Assisted Preoperative Surgical Planning for Cerebral Arteriovenous Malformation

        Uzunoglu, Inan,Kizmazoglu, Ceren,Husemoglu, Resit Bugra,Gurkan, Gokhan,Uzunoglu, Cansu,Atar, Murat,Cakir, Volkan,Aydin, Hasan Emre,Sayin, Murat,Yuceer, Nurullah The Korean Neurosurgical Society 2021 Journal of Korean neurosurgical society Vol.64 No.6

        Objective : The aim of this study to investigate the benefits of patient-based 3-dimensional (3D) cerebral arteriovenous malformation (AVM) models for preoperative surgical planning and education. Methods : Fifteen patients were operated on for AVMs between 2015 and 2019 with patient-based 3D models. Ten patients' preoperative cranial angiogram screenings were evaluated preoperatively or perioperatively via patient-based 3D models. Two patients needed emergent surgical intervention; their models were solely designed based on their AVMs and used during the operation. However, the other patients who underwent elective surgery had the modeling starting from the skull base. These models were used both preoperatively and perioperatively. The benefits of patients arising from treatment with these models were evaluated via patient files and radiological data. Results : Fifteen patients (10 males and five females) between 16 and 66 years underwent surgery. The mean age of the patients was 40.0±14.72. The most frequent symptom patients observed were headaches. Four patients had intracranial bleeding; the symptom of admission was a loss of consciousness. Two patients (13.3%) belonged to Spetzler-Martin (SM) grade I, four (26.7%) belonged to SM grade II, eight (53.3%) belonged to SM grade III, and one (6.7%) belonged to SM grade IV. The mean operation duration was 3.44±0.47 hours. Three patients (20%) developed transient neurologic deficits postoperatively, whereas three other patients died (20%). Conclusion : Several technological innovations have emerged in recent years to reduce undesired outcomes and support the surgical team. For example, 3D models have been employed in various surgical procedures in the last decade. The routine usage of patient-based 3D models will not only support better surgical planning and practice, but it will also be useful in educating assistants and explaining the situation to the patient as well.

      • KCI등재

        Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

        Uzunoglu-Ozyurek, Emel,Eren, Selen Kucukkaya,Eraslan, Oguz,Belli, Sema The Korean Academy of Conservative Dentistry 2019 Restorative Dentistry & Endodontics Vol.44 No.2

        Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. $135^{\circ}$ angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.

      • KCI등재

        Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator

        Uzunoglu, Emel,Eymirli, Ayhan,Uyanik, Mehmet Ozgur,Calt, Semra,Nagas, Emre The Korean Academy of Conservative Dentistry 2015 Restorative Dentistry & Endodontics Vol.40 No.1

        Objectives: This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. Materials and Methods: Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to one of the experimental groups according to the CH removal technique (n = 14): 0.9% saline; 0.9% saline + master apical file (MAF); 17% ethylenediamine tetraacetic acid (EDTA); 17% EDTA + MAF; 5.25% sodium hypochlorite (NaOCl); 5.25% NaOCl + MAF. Six teeth were used as negative control. After CH removal, the electronic working length was measured using Root-ZX (Morita Corp.) and compared with TWL to evaluate Root-ZX accuracy. All specimens were sectioned longitudinally, and the area of remaining CH (CH) and total canal area were measured using imaging software. Results: The EDTA + MAF and NaOCl + MAF groups showed better CH removal than other groups (p < 0.05). Root-ZX reliability to prevent overestimated working length to be > 85% within a tolerance of ${\pm}1.0mm$ (p < 0.05). There was strong negative correlation between amount of CH residues and EAL accuracy (r = -0.800 for ${\pm}0.5mm$; r = -0.940 for ${\pm}1.0mm$). Conclusions: The mechanical instrumentation improves the CH removal of irrigation solutions although none of the techniques removed the dressing completely. Residues of CH medication in root canals affected the accuracy of Root-ZX adversely.

      • SCIESCOPUSKCI등재

        Investigation of Degradative Signals on Outdoor Solid Insulators Using Continuous Wavelet Transform

        Uzunoglu, Cengiz Polat The Korean Institute of Electrical Engineers 2016 Journal of Electrical Engineering & Technology Vol.11 No.3

        Most outdoor solid insulators may suffer from surface degradations due to non-stationary currents that flow on the insulator surface. These currents may be classified as leakage, discharge and tracking currents due to their disturbing potencies respectively. The magnitude of these currents depends on the degree of the contamination of surface. The leakage signals are followed by discharge signals and tracking signals which are capable of forming carbonized tracking paths on the surface between high voltage and earth contacts (surface tracking). Surface tracking is one of the most breakdown mechanisms observed on the solid insulators, especially polymers which may cause severely reduced lifetime. In this study the degradations observed on polyester resin based insulators are investigated according to the IEC 587 Inclined Plane Test Standard. The signals are monitored and recorded during tests until surface tracking initiated. In order to prevent total breakdown of an insulator, early detection of tracking signals is vital. Continuous Wavelet Transform (CWT) is proposed for classification of signals and their energy levels observed on the surface. The application of CWT for processing and classification of the surface signals which are prone to display high frequency oscillations can facilitate real time monitoring of the system for diagnosis.

      • SCIESCOPUSKCI등재

        Biofilm-forming ability and adherence to poly-(methyl-methacrylate) acrylic resin materials of oral Candida albicans strains isolated from HIV positive subjects

        Uzunoglu, Emel,Bicer, Arzu Zeynep Yildirim,Dolapci, Istar,Dogan, Arife The Korean Academy of Prosthodonitics 2014 The Journal of Advanced Prosthodontics Vol.6 No.1

        PURPOSE. This study evaluated the adhesion to acrylic resin specimens and biofilm formation capability of Candida albicans strains isolated from HIV positive subjects' oral rinse solutions. MATERIALS AND METHODS. The material tested was a heat-cured acrylic resin (Acron Duo). Using the adhesion and crystal violet assays, 14 oral Candida albicans isolated from HIV-positive subjects and 2 references Candida strains (C. albicans ATCC 90028 and C. albicans ATCC 90128) were compared for their biofilm production and adhesion properties to acrylic surfaces in vitro. RESULTS. There were no significant differences in adhesion (P=.52) and biofilm formation assays (P=.42) by statistical analysis with Mann-Whitney test. CONCLUSION. Denture stomatitis and increased prevalence of candidal carriage in HIV infected patients is unlikely to be related to the biofilm formation and adhesion abilities of C. albicans to acrylic resin materials.

      • KCI등재

        Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

        Uzunoglu-Ozyurek, Emel,Karaaslan, Hakan,Turker, Sevinc Aktemur,Ozcelik, Bahar The Korean Academy of Conservative Dentistry 2018 Restorative Dentistry & Endodontics Vol.43 No.1

        Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

      • KCI등재

        Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator

        Emel Uzunoglu,Ayhan Eymirli,Mehmet Özgür Uyanik,Semra Çalt,Emre Nagas 대한치과보존학회 2015 Restorative Dentistry & Endodontics Vol.40 No.1

        Objectives: This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. Materials and Methods: Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to one of the experimental groups according to the CH removal technique (n = 14): 0.9% saline; 0.9% saline + master apical file (MAF); 17% ethylenediamine tetraacetic acid (EDTA); 17% EDTA + MAF; 5.25% sodium hypochlorite (NaOCl); 5.25% NaOCl + MAF. Six teeth were used as negative control. After CH removal, the electronic working length was measured using Root-ZX (Morita Corp.) and compared with TWL to evaluate Root-ZX accuracy. All specimens were sectioned longitudinally, and the area of remaining CH (CH) and total canal area were measured using imaging software. Results: The EDTA + MAF and NaOCl + MAF groups showed better CH removal than other groups (p < 0.05). Root- ZX reliability to prevent overestimated working length to be > 85% within a tolerance of ± 1.0 mm (p < 0.05). There was strong negative correlation between amount of CH residues and EAL accuracy (r = -0.800 for ± 0.5 mm; r = -0.940 for ± 1.0 mm). Conclusions: The mechanical instrumentation improves the CH removal of irrigation solutions although none of the techniques removed the dressing completely. Residues of CH medication in root canals affected the accuracy of Root-ZX adversely.

      • KCI등재

        Biofilm-forming ability and adherence to poly-(methylmethacrylate) acrylic resin materials of oral Candida albicans strains isolated from HIV positive subjects

        Emel Uzunoglu,Arzu Zeynep Yildirim Bic,Istar Dolapci,Arife Dogan 대한치과보철학회 2014 The Journal of Advanced Prosthodontics Vol.6 No.1

        PURPOSE. This study evaluated the adhesion to acrylic resin specimens and biofilm formation capability of Candida albicans strains isolated from HIV positive subjects’oral rinse solutions. MATERIALS AND METHODS. The material tested was a heat-cured acrylic resin (Acron Duo). Using the adhesion and crystal violet assays, 14 oral Candida albicans isolated from HIV-positive subjects and 2 references Candida strains (C. albicans ATCC 90028 and C. albicans ATCC 90128) were compared for their biofilm production and adhesion properties to acrylic surfaces in vitro. RESULTS. There were no significant differences in adhesion (P=.52) and biofilm formation assays (P=.42) by statistical analysis with Mann-Whitney test. CONCLUSION. Denture stomatitis and increased prevalence of candidal carriage in HIV infected patients is unlikely to be related to the biofilm formation and adhesion abilities of C. albicans to acrylic resin materials.

      • KCI등재

        Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

        Emel Uzunoglu-Özyürek,Selen Küçükkaya Eren,Oğuz Eraslan,Sema Belli 대한치과보존학회 2019 Restorative Dentistry & Endodontics Vol.44 No.2

        Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. 135° angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.

      • KCI등재

        Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

        Emel Uzunoglu-Özyürek,Hakan Karaaslan,Sevinç Aktemur Türker,Bahar Özçelik 대한치과보존학회 2018 Restorative Dentistry & Endodontics Vol.43 No.1

        Objectives To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼