http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Expansion of the mandibular arch using a trombone appliance
Sabuncuoglu, Fidan Alakus,Karacay, Seniz,Olmez, Huseyin The Korean Association Of Orthodontists 2011 대한치과교정학회지 Vol.41 No.3
Objective: This case report describes orthodontic treatment of contracted mandibular arch using a trombone appliance. Methods: A 14-year-old girl with Class II division 2 malocclusion, retroclined maxillary incisors, and buccally displaced maxillary canines required dental expansion in 3 spatial directions to correct the contracted maxillary and mandibular arches. In the initial phase of treatment, the maxillary arch was expanded and distalized using a quad-helix appliance and cervical headgear. Following the expansion and leveling of the maxillary arch, a trombone appliance was used to expand the mandibular arch. On correction of the mandibular arch and provision of sufficient space to level the mandibular teeth, fixed orthodontic treatment phase was initiated. Results: A trombone appliance proved effective in correcting the contracted mandibular arch. Because of labiolingual and transversal expansion, the mandibular dental arch perimeter was increased by 7.4 mm; the misalignment of the mandibular teeth was corrected successfully. Conclusions: A trombone appliance may serve as an appropriate clinical alternative for treating moderate mandibular arch crowding caused by the contraction of the dental arch.
Expansion of the mandibular arch using a trombone appliance
Fidan Alakus Sabuncuoglu,?eniz Karacay,Huseyin Olmez 대한치과교정학회 2011 대한치과교정학회지 Vol.41 No.3
Objective: This case report describes orthodontic treatment of contracted mandibular arch using a trombone appliance. Methods: A 14-year-old girl with Class II division 2 malocclusion, retroclined maxillary incisors, and buccally displaced maxillary canines required dental expansion in 3 spatial directions to correct the contracted maxillary and mandibular arches. In the initial phase of treatment, the maxillary arch was expanded and distalized using a quad-helix appliance and cervical headgear. Following the expansion and leveling of the maxillary arch, a trombone appliance was used to expand the mandibular arch. On correction of the mandibular arch and provision of sufficient space to level the mandibular teeth, fixed orthodontic treatment phase was initiated. Results: A trombone appliance proved effective in correcting the contracted mandibular arch. Because of labiolingual and transversal expansion, the mandibular dental arch perimeter was increased by 7.4 ㎜; the misalignment of the mandibular teeth was corrected successfully. Conclusions: A trombone appliance may serve as an appropriate clinical alternative for treating moderate mandibular arch crowding caused by the contraction of the dental arch.
Effects of Egg Storage Material and Storage Period on Hatchability in Japanese Quail
Lacin, E.,Coban, O.,Sabuncuoglu, N. Asian Australasian Association of Animal Productio 2008 Animal Bioscience Vol.21 No.8
The present study aimed to determine the effects of different storage materials and storage period on some hatchability traits of Japanese quail (Coturnix coturnix japonica) eggs. A total of 32 male and 102 female quail (twelve weeks of ages) were housed in multiple-bird cages. Eggs laid were divided into three groups with respect to the period of storage (I = 1st, 2nd and 3rd days, II = 6th, 7th and 8th days, III = 12th, 13th and 14th days) prior to incubation. A total of 816 eggs was stored in 3 different storage environments during each storage period (B = no use of any storage material, P = use of perlite, H = use of hay) and kept in environmental conditions, where the temperature was $21^{\circ}C$ and relative humidity was 75%, prior to incubation. Statistical analyses were performed after the exclusion of values pertaining to non-fertile eggs (190 eggs) from the data set. The fertility rate of the eggs in the experiment was 76.7%. In the present study, the influence of storage material and different storage periods on egg weight loss were found to be statistically significant (p<0.01). Upon the comparison of hatchability of fertile eggs values, the influence of storage material was determined to be significant (p<0.05), and the influence of storage period was demonstrated to be significant (p<0.01). The storage materials used were determined not to have any influence on early and late embryonic death rates. Perlite was concluded to be safe for use in the storage of hatching eggs. The extension of the storage period (more than 8 days) resulted in decreased hatchability values of fertile eggs in each group.
Coban, Omer,Lacin, Ekrem,Sabuncuoglu, Nilufer,Ozudogru, Zekeriya Asian Australasian Association of Animal Productio 2009 Animal Bioscience Vol.22 No.3
The weekly liveweight gain, growing and stress parameters of quails bred using two different types of lighting for 6 weeks following hatching were examined in this study. The first type of lighting was 23 L:1 D, continuous lighting (CL), widely used in the commercial system and the second was a self-photoperiod (SP) system consisting of a continuously lit chamber and a dark chamber the quails could move to as they wished. On the first 15 days, no difference was found in liveweight gain between the two breeding systems. On the $6^{th}$ week when the trial was completed, the liveweight of the male quails upon which CL lighting was used was 159.03 g while the weight of males in the SP group was 174.43 g; these values in female quails of the CL group were 179.15 g and in the SP group were 200.68 g. The CL group had lower testis volume (TVOM, $cm^{3}$) and testis weight (TW, g) than the SP group, however there was no difference between the groups in testis weight/body weight rate (BWTW %). In female quails, the ovary weight (OW, g) and the ovary weight/body weight rate (BWOW, %) values were higher in the SP group. The CL light regime was concluded to cause stress in male quails (CL, Heterophil/Lymphocyte ratio (H/L): 0.27; SP, H/L: 0.17). In conclusion; the SP system allowing the quails to regulate their light periods increased liveweight gain and enabled sexual maturity to be gained at an earlier period than in quail on the CL system and improved their welfare.