RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        CT- versus MRI-Based Imaging for Thrombolysis and Mechanical Thrombectomy in Ischemic Stroke: Analysis from the Austrian Stroke Registry

        Stefan Krebs,Alexandra Posekany,Alina Pilz,Julia Ferrari,Alexandra Bernegger,Christian Neumann,Siegfried Thurnher,Dominik Roth,Wilfried Lang,Marek Sykora 대한뇌졸중학회 2022 Journal of stroke Vol.24 No.3

        Background and Purpose It is unclear whether a particular stroke imaging modality offers an advantage for the acute stroke treatment. The aim of this study was to compare procedure times, efficacy and safety of thrombolysis and/or thrombectomy based on computed tomography (CT) versus magnetic resonance imaging (MRI) acute stroke imaging. Methods Data of stroke patients who received intravenous thrombolysis (IVT) and/or mechanical thrombectomy (MT) were extracted from a nationwide, prospective stroke unit registry and categorized according to initial imaging modality. Study endpoints included procedure times, symptomatic intracerebral hemorrhage (sICH), early neurological improvement, 3-month functional outcome by modified Rankin Scale (mRS) and mortality. Results Stroke patients (n=16,799) treated with IVT and 2,248 treated with MT were included. MRI-guided patients (n=2,599) were younger, had less comorbidities and higher rates of strokes with unknown onset as compared to CT-guided patients. In patients treated with IVT, no differences were observed regarding the rates of functional outcome by mRS 0–1 (adjusted odds ratio [OR], 0.87; 95% confidence interval [CI], 0.71 to 1.05), sICH (adjusted OR, 0.82; 95% CI, 0.61 to 1.08), and mortality (adjusted OR, 0.88; 95% CI, 0.63 to 1.22). Patients undergoing MT selected by MRI as compared to CT showed equal rates of functional outcome by mRS 0–2 (adjusted OR, 0.87; 95% CI, 0.65 to 1.16), sICH (adjusted OR, 0.9; 95% CI, 0.51 to 1.69), and mortality (adjusted OR, 0.62; 95% CI, 0.35 to 1.09). MRI-guided patients showed a significant intrahospital delay of about 20 minutes in both the IVT and the MT group. Conclusions This large non-randomized comparison study indicates that CT- and MRI-guided patient selection for IVT/MT may perform equally well in terms of functional outcome and safety.

      • KCI등재

        Functionalization of Ti-40Nb implant material with strontium by reactive sputtering

        Markus Göttlicher,Marcus Rohnke,Yannik Moryson,Jürgen Thomas,Joachim Sann,Anja Lode,Matthias Schumacher,Romy Schmidt,Stefan Pilz,Annett Gebert,Thomas Gemming,Jürgen Janek 한국생체재료학회 2017 생체재료학회지 Vol.21 No.4

        Background: Surface functionalization of orthopedic implants with pharmaceutically active agents is a modern approach to enhance osseointegration in systemically altered bone. A local release of strontium, a verified bone building therapeutic agent, at the fracture site would diminish side effects, which could occur otherwise by oral administration. Strontium surface functionalization of specially designed titanium-niobium (Ti-40Nb) implant alloy would provide an advanced implant system that is mechanically adapted to altered bone with the ability to stimulate bone formation. Methods: Strontium-containing coatings were prepared by reactive sputtering of strontium chloride (SrCl2) in a self-constructed capacitively coupled radio frequency (RF) plasma reactor. Film morphology, structure and composition were investigated by scanning electron microscopy (SEM), time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS). High-resolution transmission electron microscopy (HR-TEM) was used for the investigation of thickness and growth direction of the product layer. TEM lamellae were prepared using the focused ion beam (FIB) technique. Bioactivity of the surface coatings was tested by cultivation of primary human osteoblasts and subsequent analysis of cell morphology, viability, proliferation and differentiation. The results are correlated with the amount of strontium that is released from the coating in biomedical buffer solution, quantified by inductively coupled plasma mass spectrometry (ICP-MS). Results: Dense coatings, consisting of SrOxCly, of more than 100 nm thickness and columnar structure, were prepared. TEM images of cross sections clearly show an incoherent but well-structured interface between coating and substrate without any cracks. Sr2+ is released from the SrOxCly coating into physiological solution as proven by ICP-MS analysis. Cell culture studies showed excellent biocompatibility of the functionalized alloy. Conclusions: Ti-40Nb alloy, a potential orthopedic implant material for osteoporosis patients, could be successfully plasma coated with a dense SrOxCly film. The material performed well in in vitro tests. Nevertheless, the Sr2+ release must be optimized in future work to meet the requirements of an effective drug delivery system.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼