슈퍼커패시터를 이용한 에너지 저장용 3㎾급 양방향 DC/DC 컨버터
송웅협(W.H. Song),김진영(J.Y. Kim),노의철(E.C. Nho),김인동(I.D. Kim),김흥근(H.G. Kim),전태원(T.W. Chun) 전력전자학회 2010 전력전자학술대회 논문집 Vol.2010 No.11
This paper describers a bidirectional DC/DC converter for charging and discharging of a supercapacitor. Simulations are carried out to see the operation and performance of the 3㎾-rated converter. Simulation results show that the charging/discharging characteristics is sufficient for the compensation of the response delay of a fuel cell.
플라이휠 저장에너지 UPS의 성능 시험을 위한 순간정전 및 전압불평형 발생기
김중원(J.W. Kim),이기수(K.S. Lee),변우열(W.Y, Byeon),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
This paper deals with a novel 3-phase power quality disturbance generator. The proposed generator can be applied to the performance that of custom power devices. Voltage sag, swell, outage unbalance and phase shift are provided by the generator. The control scheme for the disturbance generation is simple, and hardware setup is cost effective compared with conventional scheme. The operating principle of the generator is described and the usefulness verified through simulation with 10㎸A power rating.
3상 다이나믹 UPS 성능 시험을 위한 Sag-Swell 발생기
김중원(J.W. Kim),이기수(K.S. Lee),변우열(W.Y. Byun),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
This Paper describes a new 3 phase Sag-Swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. The proposed scheme has good features of simple structure, high reliability, wide range of sag and swell variation. It can also generate voltage outage. The control scheme for the generation is simple. The operation principle of the proposed scheme is described and verified through simulations.
PWM인버터의 출력 LC필터에 의한 공진전압 억제 기법
최경진(G.J. Choi),전태원(T.W. Chun),이홍희(H.H. Lee),노의철(E.C. Nho),김흥근(H.G Kim) 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
The LC filter has been generally used to filter the output voltage of PWM inverter to the sinusoidal waveform. The resonant voltage on the output voltage of PWM inverter may be generated due to LC filter. This paper proposed the algorithm to damp the resonant voltage using the virtual resistor without decreasing the efficiency by the power loss in the real resistor. The method is appled to the vector controlled induction motor driven by the PWM inverter with the LC filter. The simulation results are carried out to verify the performances of the proposed algorithm.
3-phase Voltage Sag and Outage Generator for the Test of STS in Power System
H.S. Kim,J.H. Jung,J.W. Bae,B.G. Seo,D.U. Sun,H.S. Jeong,E.C. Nho,H.G. Kim,T.W. Chun 전력전자학회 2015 ICPE(ISPE)논문집 Vol.2015 No.6
This paper deals with power quality disturbance generator for the test of STS in power system. The STS used in this system is composed with SCR thyristors. It is necessary to connect the thyristors in series in high voltage system. The major components consisting the generator are SCR thyristors, series transformers, and sliding type auto transformers, therefore, the system reliability is very high. Operating characteristics of the generator are analyzed in each mode of voltage sag and outage. Simulation is carried out for the system with the rated voltage of 330V and 10MVA power rating.
3상 전압변동발생기의 직렬변압기에 의한 전압강하 특성해석
송웅협(W.H. Song),노의철(E.C. Nho),김인동(I.D. Kim),김흥근(H.G. Kim),전태원(T.W. Chun) 전력전자학회 2010 전력전자학술대회 논문집 Vol.2010 No.7
This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.
플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS
이기수(K.S. Lee),김중원(J.W. Kim),변우열(W.Y. Byeon),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
This paper deals with the operation of a flywheel energy storage UPS. The ups has good features such as long life-time, improved efficiency, no environment problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the operation is proved through simulations.
3-Phase Voltage Disturbance Generator for the Performance Test of A Flywheel Energy Storage UPS
J.W. Kim,K.S. Lee,E.C. Nho,I.D.Kim,T.W. Chun,H.G. Kim,S.S. Lee 전력전자학회 2004 ICPE(ISPE)논문집 Vol.- No.-
In this paper a novel 3-phase voltage disturbance generator is described. Voltage sag, swell, outage, and unbalance can be provided by the proposed scheme. The main devices of the generator are SCR thyristors, sliding type autotransformers, and transformers, which makes the generator have good features of high reliability, high efficiency, and cost - effective system. Thus the generator can be used for the performance test of the custom power devices including UPS. The operating principle and the characteristics of the proposed scheme are analyzed and the simulation results show the usefulness of the generator.