RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        가압가열 및 microwave에 의한 중력분 반죽 gliadin의 항원성 변화

        곽지희(Ji-Hee Kwak),김꽃봉우리(Koth-Bong-Woo-Ri Kim),이청조(Chung-Jo Lee),김민지(Min-Ji Kim),김동현(Dong-Hyun Kim),선우찬(Chan Sunwoo),정슬아(Seul-A Jung),김현지(Hyun-Jee Kim),최정수(Jung-Su Choi),김성원(Seong-Won Kim),안동현(Dong-Hyun 한국식품과학회 2012 한국식품과학회지 Vol.44 No.1

        본 연구에서는 가압가열 및 microwave 처리에 의한 중력분 반죽 추출물 내의 gliadin 단백질의 항원성 변화에 대해 살펴보았다. 중력분 반죽에 가압가열과 microwave를 단독 또는 병행으로 처리하여 ci-ELISA, SDS-PAGE 및 immunoblotting을 실시하였으며, 가압가열 처리에 의해서 anti-gliadin IgG 항체와 gliadin과의 결합력이 다소 감소한 것을 확인하였다. 특히 30 min 이상 처리시 더욱 감소한 것으로 나타났으며, SDS-PAGE와 immunoblotting 결과에서도 gliadin band의 강도가 약해지고 항체와의 반응도 나타나지 않았다. Microwave 처리의 경우, 5 min 이상 처리시 일부 gliadin 단백질의 소실이 관찰되었으나, 항원성에는 큰 변화가 없었다. 또한 가압가열 및 microwave 병행 처리에 의해 항원-항체 결합력이 더욱 감소되었으며, 특히 가압가열 50 min, microwave 10 min 처리시 약 35.0%로 감소되었다. 이상의 결과를 통해 가압가열 처리에 의해 중력분 반죽 추출물 내 gliadin의 항원성이 감소되는 것을 확인하였으며, microwave와 병행 처리하는 경우, 더욱 감소하는 것을 확인하였다. The aim of this study was to determine the optimal physical treatment to reduce the antigenicity of gliadin in wheat dough. Medium wheat dough was treated with an autoclave (5, 10, 30, and 50 min at 121℃, 1 atm), a microwave (1, 5, and 10 min) or both (10, 30, and 50 min/5, 10 min). The proteins in the dough extracts were analyzed by SDS-PAGE and the binding ability of anti-gliadin IgG to gliadin was examined by ci-ELISA and immunoblotting. Results showed that the ability of anti-gliadin IgG to bind to gliadin in wheat dough treated with an autoclave alone or in combination with a microwave was decreased. Especially, it declined to ~77% after autoclaving for 30 min and 35% after both autoclaving for 50 min and microwaving for 5 min. In addition, the intensity of gliadin bands in SDS-PAGE were weakened and anti-gliadin IgG did not recognize gliadin in immunoblotting. However, microwaving alone did not affect the antigenicity of gliadin in wheat dough. These results indicate that autoclaving may affect the reduction of the antigenicity of gliadin in medium wheat dough. Moreover, autoclaving in combination with microwaving is more effective for reducing the antigenicity of wheat dough.

      • KCI등재

        가압가열 및 Microwave 처리가 생면의 품질에 미치는 영향

        박시우,김꽃봉우리,김민지,강보경,박원민,김보람,박홍민,최정수,최호덕,안동현,Bark, Si-Woo,Kim, Koth-Bong-Woo-Ri,Kim, Min-Ji,Kang, Bo-Kyeong,Pak, Won-Min,Kim, Bo-Ram,Park, Hong-Min,Choi, Jung-Su,Choi, Ho-Duk,Ahn, Dong-Hyun 한국식품영양학회 2013 韓國食品營養學會誌 Vol.26 No.4

        중력분을 이용하여 제면한 후 가압가열, microwave 및 가압가열과 microwave 병행 처리한 후, 생면 및 삶은 면의 품질에 미치는 영향에 대하여 알아보았다. 생면의 pH는 microwave 1 min 처리구에서 무처리구와 유의적인 차이를 보이지 않았으며, 수분 함량은 autoclave 50 min 처리구에서 무처리구와 유의적인 차이를 보이지 않았고, 그 외의 처리구에서는 모두 수분 함량이 감소함을 확인하였다. 면의 색도 측정 결과는 명도는 무처리구에 비해 모든 처리구에서 감소하였으며, 적색도는 microwave 1 min 처리구는 감소한 반면, 나머지 처리구는 증가하였다. 황색도는 autoclave 50 min 처리구와 autoclave 50 min/microwave 1 min 병행 처리구에서 증가한 반면, 나머지 물리적 처리구에서는 감소하였다. 삶은 면의 색도에서는 명도, 적색도, 황색도 모두에서 무처리구에 비하여 물리적 처리구에서 증가한 값을 나타내었다. 물성 측정 결과는 경도, 부착성, 응집성, 검성, 복원성에서 무처리구와 비교시 microwave 1 min 처리구는 유의적으로 감소하였으며, 그 외 처리구에서는 유의적으로 증가한 값을 나타내었다. 탄력성과 전단력은 모든 처리구에서 유의적으로 증가하였으며, 인장력은 가압가열 30 min 처리구와 무처리구가 유의적인 차이를 보이지 않았으나, 나머지 물리적 처리구에서는 유의적으로 증가하였다. 관능 평가 결과는 생면의 경우 색 항목에서 물리적 처리구들이 유의적으로 낮은 점수를 받았다. 맛, 질감, 향 항목에서는 무처리구와 물리적 처리구간 유의적 차이를 보이지 않았다. 전체적인 기호도에서는 microwave 1 min 처리구가 가장 높은 점수를 얻었으며, 가압가열(50 min)과 microwave(1 min) 병행 처리구는 무처리구와 비슷한 점수를 얻었다. 따라서 제면 후 가압가열 및 microwave 처리가 생면 및 삶은 면에 있어서 색과 질감 항목을 보완, 개선시킨다면 알러겐성이 저감화된 면을 제품화하는데 적합할 것으로 사료되어진다. This study was conducted to determine the effects of physical treatments for quality of wet noodles. Noodles were being tried with a microwave (for 1 min), an autoclave (for 30 or 50 min), and both autoclave and microwave (for 30/1 min or 50/1 min). The results showed that the pH levels were slightly decreased after treatments of autoclave and autoclave/microwave. The moisture contents were considerably decreased as compared to the control except autoclave (50 min). After all treatments, the lightness was decreased in all samples, but, redness was increased (except microwave) and the yellowness was increased after autoclave (50 min) and autoclave/microwave (50/1 min). Texture was increased as compared to the control except microwave. In the sensory evaluation, the noodles treated with microwave, autoclave (50 min), and autoclave/ microwave (50/1 min) showed a high score in overall preference. From these results, both the autoclave and microwave methods can be applied to the wet noodles without diminishing its quality to a great extent.

      • KCI등재

        가압가열 및 Microwave 처리에 의한 중력분 Gliadin의 항원성 변화

        곽지희(Ji-Hee Kwak),김꽃봉우리(Koth-Bong-Woo-Ri Kim),이청조(Chung-Jo Lee),김민지(Min-Ji Kim),김동현(Dong-Hyun Kim),선우찬(Chan Sunwoo),정슬아(Seul-A Jung),강주연(Ju-Youn Kang),김현지(Hyun-Jee Kim),최정수(Jung-Su Choi),김성원(Seong-Won 한국식품영양과학회 2011 한국식품영양과학회지 Vol.40 No.10

        본 연구에서는 가압가열 및 microwave 처리가 gliadin의 항원성에 미치는 영향을 살펴보기 위해 중력분에 가압가열과 microwave를 단독 또는 병행으로 처리하여 Ci-ELISA, SDS-PAGE 및 immunoblotting을 실시하였다. 가압가열 처리의 경우, 처리 시간이 길어질수록 IgG와의 결합력이 감소하였으며, 특히 50분 처리구에서 약 69%로 가장 낮은 결합력을 보였다. 또한 SDS-PAGE와 immunoblotting 결과에서도 무처리구에서 강하게 보였던 gliadin band가 처리에 의해 거의 소실되고 항체와 반응하지 않았다. 가압가열 및 microwave를 병행 처리한 경우도 마찬가지로 gliadin의 결합력이 다소 감소하였으며, 처리구 중에서는 가압가열 50분, microwave 5분 처리구에서 약 73%로 가장 낮은 결합력을 보였다. 반면 microwave를 단독으로 처리하였을 때에는 일부 단백질의 변화는 관찰되었으나 항원성 감소에는 큰 영향을 미치지 않았다. 이상의 결과를 통해 가압가열을 단독 처리에 의해 gliadin의 항원성이 다소 감소되었으며, microwave 병행 처리에 의한 차이는 크게 나타나지 않은 것을 확인하였다. This study was conducted to evaluate the effect of physical treatments on the antigenicity of gliadin in medium wheat flour. The wheat flour was treated with an autoclave (5, 10, 30, 50 min), a microwave (1, 5, 10 min), and both (10, 30, 50 min/ 5, 10 min), and investigated by SDS-PAGE, immunoblotting and Ci-ELISA using anti-gliadin IgG. The results showed that the binding ability of anti-gliadin IgG to gliadin in wheat flour was slightly decreased when autoclaved or when autoclaved and microwaved. Especially, it was reduced to about 69% after autoclaving for 50 min and 73% after autoclaving for 50 min and microwaving for 5 min. In addition, gliadin bands in the 50 min autoclaved group disappeared in both SDS-PAGE and immunoblotting. On the other hand, the antigenicity of gliadin was unaffected by microwaving alone. Consequently, there were no considerable changes in using an autoclave alone or in combination with a microwave. These results suggest that autoclaving may affect the reduction of the antigenicity of gliadin in medium wheat flour.

      • KCI등재

        Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

        Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

        Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

      • KCI등재

        태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-

        이봉효 ( Bong Hyo Lee ),이경민 ( Kyung Min Lee ),박지하 ( Ji Ha Park ),김민서 ( Min Seo Kim ),김산들 ( San Deul Kim ),박병규 ( Byeong Gyu Park ),양현동 ( Hyun Dong Yang ),예성호 ( Sung Ho Yea ),이호정 ( Ho Jung Lee ),최재원 ( Jae 경락경혈학회 2012 Korean Journal of Acupuncture Vol.29 No.2

        Objectives: This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods: The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographi change was evaluated using paired t-test and post hoc Wilcoxon test. Results: The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions: The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.

      • Comparative evaluation of the algorithms for parametric mapping of the novel myocardial PET imaging agent <sup>18</sup> F-FPTP

        Kim, Ji Who,Seo, Seongho,Kim, Hyeon Sik,Kim, Dong-Yeon,Lee, Ho-Young,Kang, Keon Wook,Lee, Dong Soo,Bom, Hee-Seung,Min, Jung-Joon,Lee, Jae Sung Springer Japan 2017 Annals of nuclear medicine Vol.31 No.6

        <P><B>Objective</B></P><P>(<SUP>18</SUP>F-fluoropentyl)triphenylphosphonium salt (<SUP>18</SUP>F-FPTP) is a new promising myocardial PET imaging tracer. It shows high accumulation in cardiomyocytes and rapid clearance from liver. We performed compartmental analysis of <SUP>18</SUP>F-FPTP PET images in rat and evaluated two linear analyses: linear least-squares (LLS) and a basis function method (BFM) for generating parametric images. The minimum dynamic scan duration for kinetic analysis was also investigated and computer simulation undertaken.</P><P><B>Methods</B></P><P><SUP>18</SUP>F-FPTP dynamic PET (18 min) and CT images were acquired from rats with myocardial infarction (MI) (<I>n</I> = 12). Regions of interest (ROIs) were on the left ventricle, normal myocardium, and MI region. Two-compartment (<I>K</I><SUB>1</SUB> and <I>k</I><SUB>2</SUB>; 2C2P) and three-compartment (<I>K</I><SUB>1</SUB>–<I>k</I><SUB>3</SUB>; 3C3P) models with irreversible uptake were compared for goodness-of-fit. Partial volume and spillover correction terms (<I>V</I><SUB><I>a</I></SUB> and <I>α</I> = 1 − <I>V</I><SUB><I>a</I></SUB>) were also incorporated. LLS and BFM were applied to ROI- and voxel-based kinetic parameter estimations. Results were compared with the standard ROI-based nonlinear least-squares (NLS) results of the corresponding compartment model. A simulation explored statistical properties of the estimation methods.</P><P><B>Results</B></P><P>The 2C2P model was most suitable for describing <SUP>18</SUP>F-FPTP kinetics. Average <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, and <I>V</I><SUB><I>a</I></SUB> values were, respectively, 6.8 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.44 in normal myocardium and 1.4 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.32, in MI tissue. Ten minutes of data was sufficient for the estimation. LLS and BFM estimations correlated well with NLS values for the ROI level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.06<I>x</I> + 0.13, <I>r</I><SUP><I>2</I></SUP> = 0.96 and <I>y</I> = 1.13<I>x</I> + 0.08, <I>r</I><SUP><I>2</I></SUP> = 0.97) and voxel level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.22<I>x</I> − 0.30, <I>r</I><SUP><I>2</I></SUP> = 0.90 and <I>y</I> = 1.26<I>x</I> + 0.00, <I>r</I><SUP><I>2</I></SUP> = 0.92). Regional distribution of kinetic parametric images (<I>αK</I><SUB>1</SUB>, <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, <I>V</I><SUB>a</SUB>) was physiologically relevant. LLS and BFM showed more robust characteristics than NLS in the simulation.</P><P><B>Conclusions</B></P><P>Fast kinetics and highly specific uptake of <SUP>18</SUP>F-FPTP by myocardium enabled quantitative analysis with the 2C2P model using only the initial 10 min of data. LLS and BFM were feasible for estimating voxel-wise parameters. These two methods will be useful for quantitative evaluation of <SUP>18</SUP>F-FPTP distribution in myocardium and in further studies with different conditions, disease models, and species.</P><P><B>Electronic supplementary material</B></P><P>The online version of this article (doi:10.1007/s12149-017-1171-6) contains supplementary material, which is available to authorized users.</P>

      • 서울의 Penicillinase Producing Neisseria Gonorrhoeae 발생빈도(1996)

        김재홍,황동규,전재홍,김윤석,김중환,김용준,이창균,임동진,김현수,조창근,김경문,박상훈,전우형,김희성,이호정,차명수,김갑형,김형석,김석우,황지환,박병순,권오상,이민수,송기훈,성소영,이인섭,부태성 대한화학요법학회 1999 대한화학요법학회지 Vol.17 No.2

        Background : In recent years, gonorrhea has been panedemic and remains one of the most commom STDs in the world, especially in developing countries. Objective & Methods: For the detection of a more effective therapeutic regimen and assessing the prevalence of PPNG, we have been trying to study the patients who have visited the VD Clinic of Choong-Ku Public Health Center in Seoul since 1980 by means of the chromogenic cephalosporin method. Results: In 1996, 139 strains of N. gonorrhoeae were isolated, among which 53(39.0%) were PPNG. Conclusion: Our results suggests that after a peak of 74.3% in 1993, the prevalence of PPNG in Seoul is gradually declining.

      • SCIEKCI등재

        Reduction of Bacillus cereus Contamination in Biofilms on Stainless Steel Surfaces by Application of Sanitizers and Commercial Detergent

        Lee, Min-Jeong,Ha, Ji-Hyoung,Kim, Yong-Su,Ryu, Jee-Hoon,Ha, Sang-Do The Korean Society for Applied Biological Chemistr 2010 Applied Biological Chemistry (Appl Biol Chem) Vol.53 No.1

        We established the effectiveness of a washing, detergent and sanitizer treatments for reducing Bacillus cereus (B. cereus) contamination in biofilms on stainless steel surfaces. A water treatment did not affect biofilms and chlorine treatments at 200 ppm for 10 min and 300 ppm for 5 min, iodophor at 200 ppm for 10 min, and QAC at 400 ppm for 10 min were used to eliminate all B. cereus cells. B. cereus cells after detergent treatment were eliminated by chlorine at 100 ppm for 10 min, 200 ppm for 5 min, and 300 ppm for 3 min, and with iodophor at 100 ppm for 10 min and 200 ppm for 10 min, and QAC at 400 ppm for 10 min.

      • KCI등재

        물리적 처리에 의한 강력분 밀가루 Gliadin의 항원성 변화

        강보경(Bo-Kyeong Kang),김꽃봉우리(Koth-Bong-Woo-Ri Kim),김민지(Min-Ji Kim),박시우(Si-Woo Bark),박원민(Won-Min Pak),김보람(Bo-Ram Kim),안나경(Na-Kyung Ahn),최연욱(Yeon-Uk Choi),최정수(Jung-Su Choi),최호덕(Ho-Duk Choi),안동현(Dong-Hyun A 한국식품영양과학회 2014 한국식품영양과학회지 Vol.43 No.4

        본 연구에서는 가압가열 및 microwave 처리가 gliadin의 항원성에 미치는 영향을 살펴보기 위해 강력분에 가압가열과 microwave를 단독 또는 병행으로 처리하여 Ci-ELISA, SDS-PAGE 및 immunoblotting을 실시하였다. 가압가열 처리의 경우 시간이 길어질수록 IgG와의 결합력이 감소하였으며, 특히 50분 처리구에서 약 87%로 가장 낮은 결합력을 보였다. 또한 SDS-PAGE와 immunoblotting 결과에서도 무처리구에서 강하게 보였던 gliadin band가 가압가열처리에 의해 거의 소실되고 항체와 반응하지 않았다. 가압가열 및 microwave를 병행 처리 시도 마찬가지로 gliadin의 결합력이 감소하였으며, 처리구 중 가압가열 50분, microwave 5분 처리구에서 약 93%로 가장 낮은 결합력을 보였다. 반면 microwave를 단독으로 처리한 경우에는 일부 단백질의 변화는 관찰되었으나, 항원성 감소에는 효과가 없음을 확인하여 단백질 변화가 항원성에는 큰 효과를 준 것 같지 않다. 이상의 결과를 통해 가압가열 단독 처리 및 가압가열 및 microwave의 병행처리 시 gliadin의 항원성이 감소함을 확인하였다. This study was conducted to evaluate the effects of physical treatments on the antigenicity of gliadin in strong wheat flour. Strong wheat flour was treated with an autoclave (5, 10, 30, 50 min), a microwave (1, 5, 10 min), or both (10, 30, 50 min/ 5, 10 min), followed by SDS-PAGE, immunoblotting, and Ci-ELISA using anti-gliadin IgG. The results indicated that the binding ability of IgG to gliadin in strong wheat flour slightly decreased after autoclaving or autoclaving/microwaving. In particular, the binding ability was reduced to about 87% after autoclaving for 50 min and to 89% after autoclaving/microwaving (50/5 min). In addition, gliadin bands in the 50 min autoclaved group disappeared in both SDS-PAGE and immunoblotting. On the other hand, the antigenicity of gliadin was unaffected by microwaving alone. In conclusion, the results of this study suggest that autoclaving may reduce the antigenicity of gliadin in strong wheat flour.

      • Relieving effects of electroacupuncture on mechanical allodynia in neuropathic pain model of inferior caudal trunk injury in rat : mediation by spinal opioid receptors

        Kim, Ji Hoon,Min, Byung-Il,Na, Heung Sik,Park, Dong Suk WHO COLLABORATING CENTRE FOR TRADITIONAL MEDICINE 2003 東西醫學硏究所 論文集 Vol.2003 No.-

        The relieving effects of electroacupuncture (EA) on mechanical allodynia and its mechanism related to the spinal opioid system were investigated in a rat inodel of neuropathic pain. To produce neuropathic pain in the tail, the right superior caudal trunk was resected between the S1 and S2 spinal nerves. Two weeks after the surgery, EA stimulation (2 or 100 ㎐, 0.3ms 0.2 - 0.3 ㎃) was delivered to Zusanli (ST36) for 30 min. The degree of mechanical allodynia was evaluated quantitatively by touching the tail with von Frey hair (2.0g) at 10 min intervals. These rats were then subjected to an i.t. injection with one of the three specific opioid agonists in successive ways: the mu agonist (DAMGO 25, 50 and 100 pmol), the delta agonist (DADELT Ⅱ 0 5, 1 and 2 nmol), and the kappa agonist (U50488H 5, 10 and 20 nmol) separated by 10 min in cumulative doses. During 30 min of EA stimulation, specific opioid antagonists were subjected to i.t. injection: the mu antagonist (β-FNA 5, 10 and 20 nmol), the delta antagonist (naltrindole 5, 10 and 20 nmol), and the kappa antagonist (nor-BNI 3, 6 and 12 nmol) separated by 10 min in cumulative doses. As a result, EA reduced the behavioral signs of mechanical allodynia. Two ㎐ EA induced a robust and longer lasting effect than 100㎐. All three opioid agonists also showed relieving effects on mechanial allodynia. However, nor-BNI could not block the EA effects on mechanical allodynia, whereas β-FNA or naltrindole significantly blocked EA effects. These results suggest that the mu and delta, but not kappa opioid receptors in the spinal cord of the rat, play important roles in mediating relieving effects on mechanical allodynia induced by 2 ㎐ EA.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼