http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Development of the Local Pop Music Online Archive System-A Case Study of K-Pop
Kyeol Park,Jae Yeong Lee 보안공학연구지원센터 2014 International Journal of Software Engineering and Vol.8 No.11
The K-pop music is considered to be planned products through a very comprehensive systematic production by major entertainment companies. This study starts from a question of whether this well-organized, nurtured music is a representative pop content of Korea. The local musicians who are not affiliated with those major companies are less exposed to the public and more often than not, they have few chances to publicize and promote their music and themselves. In this context, this study suggests establishing the local pop music archive online system to bridge local musicians to music consumers. It also helps acquire diversity in pop music in Korea.
의료용 무선 중계 시스템용 이중 대역 인체 부착형 안테나 설계
권결(Kyeol Kwon),탁진필(Jinpil Tak),최재훈(Jaehoon Choi) 한국전자파학회 2013 한국전자파학회논문지 Vol.24 No.3
본 논문에서는 MICS(Medical Implant Communication Service, 402~405 MHz)와 ISM(The Industrial, Scientific and Medical, 2.40~2.485 GHz) 대역에서 동작하는 의료용 무선 중계 시스템을 위한 이중 대역 인체 부착형 안테나를 제안하고, 인체의 영향을 고려한 안테나 성능에 대한 분석을 하였다. 제안된 안테나는 ISM 대역에서 동작하는 윗면의 패치와 MICS 대역에서 동작하는 바닥면의 패치로 구성되어 있다. 안테나가 실제 인체에 착용되어 사용되는 상황을 고려하고, 인체가 안테나에 미치는 영향을 분석하기 위하여 모의 인체를 이용하여 시뮬레이션과 측정을 수행하였다. 제안된 안테나의 반사 손실은 MICS 대역과 ISM 대역에서의 요구 대역폭을 만족하였고, 측정된 최대 이득은 MICS 대역과 ISM 대역에서 각각 ?12.47 dBi, 1.71 dBi이었다. 제안된 안테나의 방사 패턴은 MICS 대역에서 인체 내부 지향성, ISM 대역에서 인체 외부 지향성을 가지며, 반사 손실 특성은 인체의 영향에 매우 둔감하므로 의료용 무선 중계 시스템용 인체 부착형 안테나로 활용되기에 적절할 것으로 사료된다. In this paper, a dual-band on-body antenna operating at MICS and ISM band for a wireless medical repeater system is proposed and the antenna performance including the human body effect is investigated. The designed dual-band antenna is comprised of a top patch for ISM band and bottom patch for MICS band. Simulation and measurement was carried out in order to analyze the effects of human body on antenna performance considering real use. The proposed antenna has required impedance bandwidth enough to cover both MICS and ISM bands. The measured peak gains were ?12.47 dBi and 1.71 dBi at the each center frequency of MICS and ISM bands, respectively. Furthermore, the antenna has the maximum radiation directed toward the inside of the human body in the MICS band and directed toward the outside in the ISM band. In addition, the return loss property of the antenna is insensitive to human body effects so that the proposed antenna is well suited for the on-body wireless medical repeater system.
Non-Bianisotropy 특성을 갖는 IDC로 구성된 메타 물질 단위 셀 설계
권결(Kyeol Kwon),하재근(Jaegeun Ha),이영기(Youngki Lee),최재훈(Jaehoon Choi) 한국전자파학회 2012 한국전자파학회논문지 Vol.23 No.3
본 논문에서는 non-bianisotropy 특성을 갖는 IDC(Interdigital Capacitor)를 이용한 메타 물질(metamaterial) 단위 셀 구조를 제안하였다. IDC 단위 셀에 유도되는 자기 공진으로 인하여 SRR(Spilt Ring Resonator)와 같이 특이한 유효 매질 파라미터 값들이 나타내게 된다. 제안된 단위 셀은 기존의 SRR 단위 셀 구조에 비하여 전기적으로 더 작게 설계할 수 있다. 도파관 측정법을 이용하여 얻은 응답 특성을 통해 추출된 셀의 유효 파라미터 값은 시뮬레이션을 통해 얻어진 결과와 유사한 특성을 보였다. In this paper, we proposed a novel metamaterial unit cell utilizing an interdigital capacitor(IDC) with non-bianisotropic property. Due to the induced magnetic resonance of an IDC unit cell, exotic effective constitutive parameters can be realized like a split ring resonator(SRR). Furthermore, the proposed unit cell is electrically smaller than a conventional SRR unit cell. The effective parameters retrieved from the transmission responses of waveguide measurement method and simulated results show good agreement.
Design of a Dual-Band On-Body Antenna for a Wireless Body Area Network Repeater System
Kwon, Kyeol,Ha, Jaegeun,Lee, Soonyong,Choi, Jaehoon Hindawi Limited 2012 International journal of antennas and propagation Vol.2012 No.-
<P>A dual-band on-body antenna for a wireless body area network repeater system is proposed. The designed dual-band antenna has the maximum radiation directed toward the inside of the human body in the medical implantable communication service (MICS) band in order to collect vital information from the human body and directed toward the outside in the industrial, scientific, and medical (ISM) band to transmit that information to a monitoring system. In addition, the return loss property of the antenna is insensitive to human body effects by utilizing the epsilon negative zeroth-order resonance property.</P>
Chang, Kyeol,Shinzawa, Hideyuki,Chung, Hoeil Academic Press 2018 Microchemical Journal Vol. No.
<P><B>Abstract</B></P> <P>When near-infrared (NIR) spectroscopy is employed to determine the concentrations of inorganic acids in etchant solutions, the perturbation of the water bands resulting from the interactions with these acids is the only information available for analysis, since inorganic acids do not directly absorb NIR radiation. The water bands perturbed by dissociated hydronium ions and respective anions of the acids are not highly component-specific; therefore, characterization of their different interactions with water is necessary to understand the results of the multivariate quantitative analysis. For this purpose, the variations in the water bands that occurred with the inclusion of HCl, H<SUB>2</SUB>SO<SUB>4</SUB>, H<SUB>3</SUB>PO<SUB>4</SUB>, and HNO<SUB>3</SUB> were initially examined with the aid of a two-dimensional (2D) correlation analysis. According to this analysis, components with higher acidity, such as HCl, perturbed the water hydrogen bonding network more strongly. Also, the interactions between each dissociated ionic species and water molecules were somewhat dissimilar. This dissimilarity enabled differentiation between the four acids, although the spectral specificity was not high owing to the absence of direct NIR absorption. The accuracy in the determination of concentrations was better for components with lower p<I>K</I> <SUB>a</SUB>s, such as HCl and H<SUB>2</SUB>SO<SUB>4</SUB>, owing to their stronger perturbation of the water bands. When multicomponent samples were measured, the resulting accuracies deteriorated due to the further degradation in component specificity. Acquisition of reproducible spectra and avoidance of model over-fitting are critical for reliable NIR analysis of these types of samples, as the analyte-induced spectral features are broad and rather specificity-insufficient.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Inorganic acids (HCl, H<SUB>2</SUB>SO<SUB>4</SUB>, H<SUB>3</SUB>PO<SUB>4</SUB>, and HNO<SUB>3</SUB>) do not directly absorb NIR radiation. </LI> <LI> Varied NIR water band by dissociated H<SUB>3</SUB>O<SUP>+</SUP> and anion was used to determine concentration. </LI> <LI> 2D correlation analysis revealed that interaction of each acid with water molecule differed. </LI> <LI> Acidity governing strength of acid-water interaction directly influenced on accuracy. </LI> <LI> Multiple PCs were required in PLS modeling since diverse acid-water interactions occurred. </LI> </UL> </P>
사용자 행위 로그를 활용한 UX 디자인 피벗 전후 사용자 행태 분석
김결(Kyeol, Kim),김초롱(Cho-Long, Kim),하현남(Hyun-Nam, Ha),박희진(Hee-Jin, Park) 한국HCI학회 2017 한국HCI학회 학술대회 Vol.2017 No.2
최근 사용자 경험 분석 방법론에 있어서도 데이터 분석의 중요성은 날로 높아지고 있다. 과거 사용자 경험연구가 주로 설문이나 관찰 방법을 통해 이루어졌다면, 최근에는 데이터 분석 기법의 발달에 힘입어 실제 기록되는 로그 데이터 등을 기반으로 사용자 경험연구가 가능하다. 하지만 데이터 분석 역시 해당 서비스의 상태 분석 혹은 타 서비스와의 비교 분석에 그칠 뿐이다. 본 연구에서는 매월 100 만명 이상이 사용하고 있는 모바일 외식 어플리케이션 ‘Syrup 테이블’의 서비스 개선 과정(피벗, pivot)을 대상으로, 사용자 경험이 어떻게 변화하였는지 시계열적으로 비교하였다. 이에 대한 실증적 분석을 위해 모바일 사용자 행위 로그를 활용하였으며, 그 결과 피벗 전후 사용자 행태 차이점을 도출할 수 있었다. 피벗 이전의 ‘Syrup 테이블’는 맛집 콘텐츠(Contents) 탐색이 주 과업이었고, 피벗 이후 외식 상품권 구매, 포장 주문 등 커머스(Commerce) 과업으로 중심축이 변하였다. 피벗 이후 40 대 남성에서 30 대 여성으로 주 사용자층이 변화하였으며, 특히 콘텐츠 주 사용자는 콘텐츠와 커머스 과업을 동시에 수행하는 반면, 커머스주 사용자는 커머스 과업에만 집중하였다. 또한 정보탐색(Discovery) 과정에서 콘텐츠 탐색 시에는 브라우징(Browsing) 중심의 행태를, 커머스 과업 수행시에는 과업 완료(Task-Complete) 행태 특징을 보였다. 본 연구는 모바일 어플리케이션 피벗 사례를 대상으로 피벗 전후 콘텐츠와 커머스 과업에 대한 사용자 행태를 사용자 행위 로그를 활용하여 시계열 비교 분석 연구을 진행했다는데 그 의의를 가진다.
Han-Kyeol Yeo,Dong-Kyun Woo,Dong-Kuk Lim,Jong-Suk Ro,Hyun-Kyo Jung 대한전기학회 2014 Journal of Electrical Engineering & Technology Vol.9 No.6
The rotor overhang is used to enhance the air-gap flux and improve the power density. Due to the asymmetry in the axial direction caused by the overhang, a time consuming 3D analysis is necessary when designing a motor with overhang. To solve this problem, this paper proposes an equivalent magnetic circuit model (EMCM) which takes account overhang effects without a 3D analysis by using effective air-gap length. The analysis time can be reduced significantly via the proposed EMCM. A reduction in the analysis time is essential for a preliminary design of a motor. In order to verify the proposed model, a 3-D finite-element method (FEM) analysis is adopted. 3-D FEM results confirm the validity of the proposed EMCM.