http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Erkan Caglar,Gulen Doğusoy,Levent Kabasakal,Ahmet Dobrucali 대한소화기내시경학회 2016 Clinical Endoscopy Vol.49 No.5
Internal radioembolization with yttrium-90 is a promising treatment method, predominantly for liver tumors. However, the shifting of yttrium-90-loaded spherules into the arteries and veins that supply the duodenum and stomach, leading to ulceration, hemorrhage, perforation, and outlet obstruction of these organs, is one of the major undesirable consequences of this technique. We report a case of gastric outlet obstruction (GOO) due to antropyloric stenosis with ulceration, edema, and inflammation following transarterial yttrium-90 treatment for a metastatic neuroendocrine tumor in a 58-year-old man. Stenting was used for palliation in this case. GOO improved after stenting and recovery of oral intake was permanent after stent removal.
Chia seed (Salvia Hispanica L.) added yogurt reduces short‐term food intake and increases satiety
Aylin Ayaz,Asli Akyo,Elif Inan-Eroglu,Arzu Kabasakal Cetin,Gulhan Samur,Filiz Akbiyik 한국영양학회 2017 Nutrition Research and Practice Vol.11 No.5
BACKGROUND/OBJECTIVE: Several studies have reported that consumption of Salvia Hispanica L.,commonly known as chia seed, may exert beneficial effects on health outcomes. The main purpose of this study was to examine the influence of chia seed consumption as a mid-morning snack on short-term satiety. SUBJECTS/METHODS: Subjects (n = 24) were tested using a randomized, cross-over design consisting of three mid-morning snacks. Yogurt with no chia seed, yogurt with 7 g chia seed, and yogurt with 14 g chia seed were given to subjects on different test days. After subjects were asked to report visual analog scale (VAS) scores on sensory outcomes, ad libitum lunch was served, and energy intake of individuals was measured. RESULTS: VAS scores indicated that participants reported significantly lower scores for hunger (P = 0.033), prospective food consumption (P = 0.031), amounts of food that could be consumed (P = 0.017), desire for sugary foods (P = 0.015), and higher scores for satiety (P = 0.031) on the test days with 7 g and 14 g chia seed. Energy intake of individuals during ad libitum lunch was significantly lower when they consumed yogurt with 7 g or 14 g chia seed (P = 0.037). CONCLUSIONS: The study demonstrated that chia seed consumption as a mid-morning snack may induce short-term satiety in healthy individuals.
Ayaz, Aylin,Akyol, Asli,Inan-Eroglu, Elif,Cetin, Arzu Kabasakal,Samur, Gulhan,Akbiyik, Filiz The Korean Nutrition Society 2017 Nutrition research and practice Vol.11 No.5
BACKGROUND/OBJECTIVE: Several studies have reported that consumption of Salvia Hispanica L.,commonly known as chia seed, may exert beneficial effects on health outcomes. The main purpose of this study was to examine the influence of chia seed consumption as a mid-morning snack on short-term satiety. SUBJECTS/METHODS: Subjects (n = 24) were tested using a randomized, cross-over design consisting of three mid-morning snacks. Yogurt with no chia seed, yogurt with 7 g chia seed, and yogurt with 14 g chia seed were given to subjects on different test days. After subjects were asked to report visual analog scale (VAS) scores on sensory outcomes, ad libitum lunch was served, and energy intake of individuals was measured. RESULTS: VAS scores indicated that participants reported significantly lower scores for hunger (P = 0.033), prospective food consumption (P = 0.031), amounts of food that could be consumed (P = 0.017), desire for sugary foods (P = 0.015), and higher scores for satiety (P = 0.031) on the test days with 7 g and 14 g chia seed. Energy intake of individuals during ad libitum lunch was significantly lower when they consumed yogurt with 7 g or 14 g chia seed (P = 0.037). CONCLUSIONS: The study demonstrated that chia seed consumption as a mid-morning snack may induce short-term satiety in healthy individuals.
Lebriz Uslu-Bes¸li,Kerim Sonmezoglu,Serkan Teksoz,Elife Akgun,Emre Karayel,Huseyin Pehlivanoglu,Baresh Razavi Khosroshahi,Meltem Ocak,Levent Kabasakal,Sait Sager,Yusuf Bukey 대한영상의학회 2020 Korean Journal of Radiology Vol.21 No.2
Objective: Our aim was to assess the diagnostic performance of F-18 fluorocholine (FCH) positron emission tomography/ computed tomography (PET/CT) in detecting hyperfunctioning parathyroid tissue (HPT) in patients with elevated parathyroid hormone levels with negative or inconclusive conventional imaging results and to compare the findings with those obtained using technetium-99m sestamibi (MIBI) scintigraphy and neck ultrasonography (US). Materials and Methods: Images of 105 patients with hyperparathyroidism who underwent FCH PET/CT, dual-phase MIBI parathyroid scintigraphy (median interval: 42 days), and neck US were retrospectively analyzed. The gold standard was histopathological findings for 81 patients who underwent parathyroidectomy and clinical follow-up findings in the remaining 24 patients. Sensitivities, positive predictive values (PPVs), and accuracies were calculated for all imaging modalities. Results: Among the 81 patients who underwent parathyroidectomy, either parathyroid adenoma (n = 64), hyperplasia (n = 9), neoplasia (n = 4), or both parathyroid adenoma and hyperplasia (n = 1) were detected, except 3 patients who did not show HPT. Of the 24 (23%) patients who were followed-up without operation, 22 (92%) showed persistent hyperparathyroidism. FCH PET/CT showed significantly higher sensitivity than MIBI scintigraphy and US in detection of HPT (p < 0.01). Sensitivity, PPV, and accuracy of FCH PET/CT were 94.1% (95/101), 97.9% (95/97), and 92.4% (97/105), respectively. The corresponding values for MIBI scintigraphy and US were 45.1% (46/102), 97.9% (46/47), and 45.7% (48/105) and 44.1% (45/102), 93.8% (45/48), and 42.9% (45/105), respectively. Among the 35 patients showing negative MIBI scintigraphy and neck US findings, 30 (86%) showed positive results on FCH PET/CT. FCH PET/CT could demonstrate ectopic locations of HPT in 11 patients whereas MIBI and US showed positive findings in only 6 and 3 patients, respectively. Conclusion: FCH PET/CT is an effective imaging modality for detection of HPT with the highest sensitivity among the available imaging techniques. Therefore, FCH PET/CT can be recommended especially for patients who show negative or inconclusive results on conventional imaging.