http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Junbum Kwon,Sunjae Yoon,Hyungjin Kim,Sewan Choi 전력전자학회 2011 ICPE(ISPE)논문집 Vol.2011 No.5
Simultaneous disconnection of a large amount of DG systems could cause instability in the grid. Therefore, during a grid fault DG systems are required to remain connected to the grid for a certain period of time. Rather, it is necessary for DG systems to supply reactive power variably depending on actual voltage level for grid support. Further, during the grid fault the utility-interactive inverter with a critical load should not only supply reactive power to the grid but also provide well regulated voltage to the critical load. This paper proposes a reactive current injection algorithm for FRT with voltage compensation capability for the critical load. A design guideline is provided considering the increase of apparent power. The proposed algorithm is validated through simulation and experiment.
General Anesthesia of a Patient with Charcot-Marie-Tooth Disease
( Junbum Lee ),( Gahee Kim ),( Sangho Lee ),( Jeong-hyun Choi ) 경희대학교 경희의료원 2022 慶熙醫學 Vol.37 No.1
Charcot-Marie-Tooth (CMT) disease is a hereditary motor and sensory neuropathy of the peripheral nervous system. The initial presentation is usually foot drop or muscle wasting of the distal part of the leg. The symptom eventually progresses to atrophy of respiratory muscles, vocal cord and diaphragm. CMT patients require special caution during the general anesthesia. CMT disease can cause malignant hyperthermia, respiratory insufficiency and hyperkalemia during anesthesia. This report presents a 50-year-old man who has been diagnosed CMT disease and scheduled to undergo anterior cervical discectomy and fusion to treat cervical spinal stenosis. Propofol and remifentanil were used for the total intravenous anesthesia, and rocuronium was used for muscle relaxant purpose. Several intraoperative monitoring methods were performed to proceed the anesthesia safely, and the patient was discharged without any complications 5 days after the surgery. This case report with comprehensive literature review investigates possible adverse events and special cautions during the general anesthesia of CMT patients, and discusses adequate intraoperative monitoring to avoid such problems.
Precise Model Analysis for 3-phase High Power Converter using the Harmonic State Space Modeling
JunBum Kwon,Xiongfei Wang,Frede Blaabjerg,Claus Leth Bak 전력전자학회 2015 ICPE(ISPE)논문집 Vol.2015 No.6
This paper presents about the generalized multi-frequency modeling and analysis methodology, which can be used in control loop design and stability analysis. In terms of the switching frequency of high power converter, there can be harmonics interruption if the voltage source converter has a low switching frequency ratio or multisampling frequency. The range of the control bandwidth can include the switching component. Thus, the systems become unstable. This paper applies the Harmonic State Space (HSS) Modeling method in order to find out the transfer function for each harmonics terms. The modeling procedure shows the precision in the analysis of the stability as well as the controller design. The overall results are validated by using not only the non-linear time domain simulation, but also the analytical model.
계통연계형 인버터의 계통임피던스 추정알고리즘을 이용한 Active Damping 기법
권준범(Junbum Kwon),최세완(Sewan Choi),명홍재(Hongjae Myung),박가우(Gawoo Park) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
발전용 연료전지 PCS등 대용량에서 작은 인덕턴스로 동일한 고조파특성을 가질 수 있는 LCL 필터를 사용하는 것이 유리하다. 그러나 LCL필터의 사용 시 공진이 발생할 수 있으며 계통 측 인덕턴스는 계통 임피던스의 영향을 받기 때문에 LCL 필터의 공진점이 변하게 된다. 본 논문에서는 계통 임피던스 추정 알고리즘을 이용하여 LCL 필터의 공진점 변동에 대응할 수 있는 Active Damping 기법을 제안한다. 제안한 방법은 컴퓨터 시뮬레이션을 통하여 타당성을 검증한다.
계통이상에 강인한 간접전류제어 계통연계 인버터의 전압 보상기법
권준범(Junbum Kwon),윤선재(Sunjae Yoon),최세완(Sewan Choi),박가우(Gawoo Park),최재호(Jaeho Choi) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
연료전지 시스템의 경우 계통에 Sag 및 Swell 같은 이상이 발생하더라도 계통과 분리되기 전 MBOP등 자체 부하에는 안정적인 전원을 공급하는 것이 중요하다. 기존의 전류제어방식으로는 계통이상 시 전압을 제어할 수 없으므로 자체 부하에 과도상태가 매우 크다. 본 논문에서는 계통에 Sag 및 Swell 같은 상황이 발생하더라도 무효전류를 제어하여 자체 부하전압을 보상함으로써 Grid Code의 Fault Ride Through 규정에 부합 할 수 있는 알고리즘을 제안한다. 제안된 전압보상기법을 시뮬레이션과 실험으로 타당성을 검증한다.
계통연계형 연료전지 PCS의 Seamless Transfer를 위한 3상 간접전류제어 기법
권준범(Junbum Kwon),김영우(Youngwoo Kim),최세완(Sewan Choi) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
발전용 연료전지 시스템에서 PCS는 계통에 전력을 주입할 뿐만 아니라 MBOP 등 자체 부하에도 안정된 전원을 공급하는 역할을 한다. 기존의 PCS는 계통연계 시 전류제어모드로 운전되며 주전원에 고장이 발생하면 전압제어모드로 전환되어 의도적인 독립운전을 함으로써 MBOP등 자체 부하에 지속적인 전력을 공급한다. 그러나 모드 전환 시 이러한 제어방법으로는 MBOP에 공급되는 전압의 과도상태로 인하여 연료전지 스택에도 심각한 영향을 미칠 수도 있다. 본 논문에서는 독립운전 및 계통연계 시에도 전압제어를 유지함으로써 모드 전환 시 안정적인 전원을 자체 부하에 공급 할 수 있는 간접전류 제어기법을 제안한다. 제안된 3상 간접전류 제어 알고리즘을 시뮬레이션과 실험으로 검증한다.