RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The use of tantalum cones and diaphyseal-engaging stems in tibial component revision: a consecutive series

        ( P. Spinello ),( R. A. Ruberte Thiele ),( K. Zepeda ),( N. Giori ),( P. F. Indelli ) 대한슬관절학회 2022 대한슬관절학회지 Vol.34 No.-

        Introduction: Revision knee arthroplasty presents a number of challenges, including management of bone loss. The goal in managing moderate to large bone defects is fixation that is sufficient enough to allow early weight-bearing. The purpose of this study was to describe the surgical technique and clinical and radiographic outcomes of patients treated with porous tantalum metaphyseal cones in combination with long uncemented diaphyseal-engaging stems to manage tibial bone loss in revision total knee arthroplasty (TKA). Materials and methods: Thirty-six aseptic revision TKAs were performed at our institution between 2016 and 2019 by two senior authors. A single trabecular metal tantalum cone combined with a long (100 or 155 mm) press fit, diaphyseal- engaging stem was used in all cases to reconstruct metaphyseal bone defects and to augment tibial fixation. Cemented stems were excluded. The tibiofemoral angle was measured along the tibial and femoral shaft axes on the weight-bearing anteroposterior radiograph at final follow-up (range 15-56 months). All clinical and surgical complications, reoperations, and revisions of any component were recorded. Survivorship free of revision was evaluated at the time of the latest follow-up. Results: The mean Knee Society Score (KSS) and Knee Society Function Score (KSS-F) improved significantly from 29.7 points preoperatively (range 11-54 points) to 86 points (range 43-99 points) and from 20.4 points preoperatively (range 0-55 points) to 72.3 points (range 30-90 points) (p < 0.05), respectively. Eleven tibial constructs (30.5%) had incomplete, nonprogressive radiolucent lines (≤ 2 mm). All tibial cones demonstrated osteointegration. One patient underwent a full revision for periprosthetic joint infection, and survivorship free of any component revision was 91.7% at final follow-up. Conclusions: Hybrid fixation with uncemented diaphyseal-engaging stems and porous tantalum metaphyseal cones resulted in radiographic lack of osteolysis, good clinical outcomes, and survivorship of 91.7% at a median follow-up of 33 months when considering all-cause revision as the endpoint.

      • KCI등재

        Can bedside patient-reported numbness predict postoperative ambulation ability for total knee arthroplasty patients with nerve block catheters?

        Edward R. Mariano,Seshadri C. Mudumbai,Toni Ganaway,T. Edward Kim,Steven K. Howard,Nicholas J. Giori,Cynthia Shum 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.1

        Background: Adductor canal catheters offer advantages over femoral nerve catheters for knee replacement patients because they produce less quadriceps muscle weakness; however, applying adductor canal catheters in bedside clinical practice remains challenging. There is currently no patient-reported outcome that accurately predicts patients’ physical function after knee replacement. The present study evaluates the validity of a relatively new patient-reported outcome, i.e., a numbness score obtained using a numeric rating scale, and assesses its predictive value on postoperative ambulation. Methods: We conducted a retrospective cohort study pooling data from two previously-published clinical trials using identical research methodologies. Both studies recruited patients undergoing knee replacement; one studied adductor canal catheters while the other studied femoral nerve catheters. Our primary outcome was patient-reported numbness scores on postoperative day 1. We also examined postoperative day 1 ambulation distance and its association with postoperative numbness using linear regression, adjusting for age, body mass index, and physical status. Results: Data from 94 subjects were included (femoral subjects, n = 46; adductor canal subjects, n = 48). Adductor canal patients reported decreased numbness (median [10th–90th percentiles]) compared to femoral patients (0 [0–5] vs. 4 [0–10], P = 0.001). Adductor canal patients also ambulated seven times further on postoperative day 1 relative to femoral patients. There was a significant association between postoperative day 1 total ambulation distance and numbness (Beta = −2.6; 95% CI: −4.5, −0.8, P = 0.01) with R2 = 0.1. Conclusions: Adductor canal catheters facilitate improved early ambulation and produce less patient-reported numbness after knee replacement, but the correlation between these two variables is weak.

      • KCI등재

        An ultrasound-guided fascia iliaca catheter technique does not impair ambulatory ability within a clinical pathway for total hip arthroplasty

        Edward R. Mariano,Seshadri C. Mudumbai,T. Edward Kim,Steven K. Howard,Nicholas J. Giori,Steven Woolson,Toni Ganaway,Alex Kou,Robert King 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.4

        Background: Both neuraxial and peripheral regional analgesic techniques offer postoperative analgesia for total hip arthroplasty (THA) patients. While no single technique is preferred, quadriceps muscle weakness from peripheral nerve blocks may impede rehabilitation. We designed this study to compare postoperative ambulation outcome in THA patients who were treated with a new ultrasound-guided fascia iliaca catheter (FIC) technique or intrathecal morphine (ITM). Methods: We reviewed the electronic health records of a sequential series of primary unilateral THA patients who were part of a standardized clinical pathway; apart from differences in regional analgesic technique, all other aspects of the pathway were the same. Our primary outcome was total ambulation distance (meters) combined for postoperative days 1 and 2. Secondary outcomes included daily opioid consumption (morphine milligram equivalents) and analgesic-related side effects. We examined the association between the primary outcome and analgesic technique by performing crude and adjusted ordinary least-squares linear regression. A P value < 0.05 was considered statistically-significant. Results: The study analyzed the records of 179 patients (fascia iliaca, n = 106; intrathecal, n = 73). The primary outcome (total ambulation distance) did not differ between the groups (P = 0.08). Body mass index (BMI) was the only factor (β = −1.7 [95% CI −0.5 to −2.9], P < 0.01) associated with ambulation distance. Opioid consumption did not differ, while increased pruritus was seen in the intrathecal group (P < 0.01). Conclusions: BMI affects postoperative ambulation outcome after hip arthroplasty, whereas the type of regional analgesic technique used does not. An ultrasound-guided FIC technique offers similar analgesia with fewer side effects when compared with ITM.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼