RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Tomographic 2-D X-ray imaging of toroidal fusion plasma using a tangential pinhole camera with gas electron multiplier detector

        송인우,Juhyeok Jang,전태민,D. Pacella,G. Claps,F. Murtas,Seung Hun Lee,최원호 한국물리학회 2016 Current Applied Physics Vol.16 No.10

        A tangential X-ray pinhole camera based on a gas electron multiplier (GEM) detector was installed on KSTAR to study high temperature plasmas emitting X-ray photons in the energy band of 4e15 keV. The camera system consists of a triple-GEM gas chamber with a readout printed circuit board and a pinhole to image the plasma in two dimensions (2-D). The advantages of this tangential camera system include its compactness, high efficiency, energy discrimination in bands, and selectivity of the photon energy range etc. This camera system allows a selection of the viewing area through a remote control of the entire setup. The Philips-Tikhonov algorithm for tangential reconstruction was used to visualize the poloidal cross-sectional images. Phantom tests were performed with synthetic D-shaped plasma images and a comparison with the magnetic equilibrium flux surfaces from the real-time EFIT code obtaining a good agreement between each other. The 2-D X-ray images of the KSTAR plasma were successfully acquired during sawtooth crash, electron cyclotron heating, vertical displacement event, and emissivity from the injected trace Ar impurity.

      • SCIESCOPUSKCI등재

        Effects of Perinatal Nutrition on Metabolic and Hormonal Profiles of Goat Kids (Capra hircus) during Their First Day of Life

        Celi, Pietro,Di Trana, Adriana,Claps, Salvatore,Di Gregorio, Paola Asian Australasian Association of Animal Productio 2008 Animal Bioscience Vol.21 No.11

        The aim of the present work was to monitor metabolic and hormonal profiles in newborn kids, born from dams fed diets with low or high levels of energy requirements. Starting from the last month of pregnancy, 14 goats were randomly allocated to two groups: Group LD (low diet) and Group HD (high diet) that received a diet that covered 80% and 140% of their energy requirement, respectively. At delivery, the kids were weighed and a blood sample was taken before they suckled colostrum (Time 0) and 1, 2, 3, 12 and 24 h after they started suckling. Plasma insulin, IGF-I, glucose, fT3 and fT4 concentrations were not influenced by the dietary treatments, but a significant effect of time was observed as they progressively increased during the first 12 h of life. Plasma cholesterol, triglyceride, albumin, globulin and total protein plasma concentrations were significantly higher in Group HD than those of Group LD. In Group HD, cortisol concentrations were significantly lower than those of Group LD. Positive correlations were observed between LW and IGF-I (r = 0.71; p<0.05), plasma insulin and glucose (r = 0.79; p<0.05) and total protein and globulin concentrations (r = 0.97; p<0.001). Our results show that perinatal nutrition affects newborn goat kids' metabolic and hormonal profile.

      • KCI등재SCIESCOPUS

        Tomographic 2-D X-ray imaging of toroidal fusion plasma using a tangential pinhole camera with gas electron multiplier detector

        Song, I.,Jang, J.,Jeon, T.,Pacella, D.,Claps, G.,Murtas, F.,Lee, S.H.,Choe, W. Elsevier 2016 CURRENT APPLIED PHYSICS Vol.16 No.10

        <P>A tangential X-ray pinhole camera based on a gas electron multiplier (GEM) detector was installed on KSTAR to study high temperature plasmas emitting X-ray photons in the energy band of 4-15 keV. The camera system consists of a triple-GEM gas chamber with a readout printed circuit board and a pinhole to image the plasma in two dimensions (2-D). The advantages of this tangential camera system include its compactness, high efficiency, energy discrimination in bands, and selectivity of the photon energy range etc. This camera system allows a selection of the viewing area through a remote control of the entire setup. The Philips-Tikhonov algorithm for tangential reconstruction was used to visualize the poloidal cross-sectional images. Phantom tests were performed with synthetic D-shaped plasma images and a comparison with the magnetic equilibrium flux surfaces from the real-time EFIT code obtaining a good agreement between each other. The 2-D X-ray images of the KSTAR plasma were successfully acquired during sawtooth crash, electron cyclotron heating, vertical displacement event, and emissivity from the injected trace Ar impurity. (C) 2016 Elsevier B.V. All rights reserved.</P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼