RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

        Selda Arat Bilhan,Onur Geckili,Altug Cilingir,Ergun Bozdag,Hakan Bilhan 대한구강악안면외과학회 2019 대한구강악안면외과학회지 Vol.45 No.4

        Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant inter-canine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.

      • SCIESCOPUSKCI등재

        CYLOTOMIC FUNCTION FIELDS OVER FINITE FIELDS WITH CLASS NUMBER THREE

        Bilhan, Mehpare,Buyruk, Dilek,Ozbudak, Ferruh Korean Mathematical Society 2019 대한수학회지 Vol.56 No.2

        We list all subfields of cyclotomic function fields over rational function fields with class number three. We also determine all the imaginary abelian extensions with relative class number three, explicitly.

      • SCIESCOPUSKCI등재

        The use of definitive implant abutments for the fabrication of provisional crowns: a case series

        Bilhan, Hakan,Geckili, Onur,Mumcu, Emre Korean Academy of Periodontology 2011 Journal of Periodontal & Implant Science Vol.41 No.5

        Purpose: The anterior region is a challenge for most clinicians to achieve optimal esthetics with dental implants. The provisional crown is a key factor in the success of obtaining pink esthetics around restorations with single implants, by soft tissue and inter-proximal papilla shaping. Provisional abutments bring additional costs and make the treatment more expensive. Since one of the aims of the clinician is to reduce costs and find more economic ways to raise patient satisfaction, this paper describes a practical method for chair-side fabrication of non-occlusal loaded provisional crowns used by the authors for several years successfully. Methods: Twenty two patients (9 males, 13 females; mean age, 36,72 years) with one missing anterior tooth were treated by using the presented method. Metal definitive abutments instead of provisional abutments were used and provisional crowns were fabricated on the definitive abutments for all of the patients. The marginal fit was finished on a laboratory analogue and temporarily cemented to the abutments. The marginal adaptation of the crowns was evaluated radiographically. Results: The patients were all satisfied with the final appearance and no complications occurred until the implants were loaded with permanent restorations. Conclusions: The use of the definitive abutments for provisional crowns instead of provisional abutments reduces the costs and the same results can be obtained.

      • KCI등재

        The impact of frenulum height on strains in maxillary denture bases

        Hakan Bilhan,Gokhan Baysal,Emin Sunbuloglu,Ergun Bozdag,Altug Cilingir 대한치과보철학회 2013 The Journal of Advanced Prosthodontics Vol.5 No.4

        PURPOSE The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.

      • KCI등재

        Cylotomic function fields over finite fields with class number three

        Mehpare Bilhan,Dilek Buyruk,Ferruh Ozbudak 대한수학회 2019 대한수학회지 Vol.56 No.2

        We list all subfields of cyclotomic function fields over rational function fields with class number three. We also determine all the imaginary abelian extensions with relative class number three, explicitly.

      • KCI등재

        Complication rates and patient satisfaction with removable dentures

        Hakan Bilhan,Onur Geckili,Ozge Erdogan,Selen Ergin,Melahat Celik,Gokcen Ates 대한치과보철학회 2012 The Journal of Advanced Prosthodontics Vol.4 No.2

        PURPOSE The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of P<.05. RESULTS Need for addition of artificial teeth for dentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations (P<.01). Loss of retention, ulcerations and high vertical dimension affected the VAS chewing ability scores negatively and ulcerations affected the VAS phonation scores negatively (P<.05). CONCLUSION Considering the results of this study, it can be concluded that loss of retention, ulcerations and high vertical dimension caused patient dissatisfaction. Additionally, dentures with wrong centric relations caused need for addition of artificial teeth.

      • KCI등재

        The use of definitive implant abutments for the fabrication of provisional crowns: a case series

        Hakan Bilhan,Onur Geckili,Emre Mumcu 대한치주과학회 2011 Journal of Periodontal & Implant Science Vol.41 No.5

        Purpose: The anterior region is a challenge for most clinicians to achieve optimal esthetics with dental implants. The provisional crown is a key factor in the success of obtaining pink esthetics around restorations with single implants, by soft tissue and inter-proximal papilla shaping. Provisional abutments bring additional costs and make the treatment more expensive. Since one of the aims of the clinician is to reduce costs and find more economic ways to raise patient satisfaction, this paper describes a practical method for chair-side fabrication of non-occlusal loaded provisional crowns used by the authors for several years successfully. Methods: Twenty two patients (9 males, 13 females; mean age, 36,72 years) with one missing anterior tooth were treated by using the presented method. Metal definitive abutments instead of provisional abutments were used and provisional crowns were fabricated on the definitive abutments for all of the patients. The marginal fit was finished on a laboratory analogue and temporarily cemented to the abutments. The marginal adaptation of the crowns was evaluated radiographically. Results: The patients were all satisfied with the final appearance and no complications occurred until the implants were loaded with permanent restorations. Conclusions: The use of the definitive abutments for provisional crowns instead of provisional abutments reduces the costs and the same results can be obtained.

      • SCIESCOPUSKCI등재

        Assessment of demographic and clinical data related to dental implants in a group of Turkish patients treated at a university clinic

        Bural, Canan,Bilhan, Hakan,Cilingir, Altug,Geckili, Onur The Korean Academy of Prosthodonitics 2013 The Journal of Advanced Prosthodontics Vol.5 No.3

        PURPOSE. This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well as the location, dimension and type of the implants. MATERIALS AND METHODS. The data of demographics (age and gender), type of indication for implant therapy, anatomical location, dimensions (length and diameter) and type (bone and tissue level) of 1616 implants were recorded from patient charts between January 2000 and January 2010. Descriptive statistics were analyzed using a chi-squared test for demographic parameters, type of indication, tooth position, anatomical location, implant dimensions and type (${\alpha}$=.05). RESULTS. The patient pool comprised of 350 women and 266 men, with a mean age of $52.12{\pm}13.79$ years. The difference in n% of the implants of the age groups was statistically significant between the types of indications. The difference in the position of the implants was statistically significant between the n% of the implants of all age groups. Gender did not significantly vary, except that the diameter of the implants was significantly higher for the standard diameter implants in males. The difference between the implant positions was statistically significant when considered according to indication. The relationship between implant length and anatomical location was statistically significant. CONCLUSION. The indication for dental implant use is age dependent and the type and size of the implant seems to be strongly related to the location of the implant.

      • SCIESCOPUSKCI등재

        The impact of frenulum height on strains in maxillary denture bases

        Cilingir, Altug,Bilhan, Hakan,Baysal, Gokhan,Sunbuloglu, Emin,Bozdag, Ergun The Korean Academy of Prosthodonitics 2013 The Journal of Advanced Prosthodontics Vol.5 No.4

        PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.

      • SCIESCOPUSKCI등재

        In vitro comparison of two different materials for the repair of urethan dimethacrylate denture bases

        Cilingir, Altug,Bilhan, Hakan,Geckili, Onur,Sulun, Tonguc,Bozdag, Ergun,Sunbuloglu, Emin The Korean Academy of Prosthodonitics 2013 The Journal of Advanced Prosthodontics Vol.5 No.4

        PURPOSE. The purpose of this in vitro study was to investigate the flexural properties of a recently introduced urethane dimethacrylate denture base material (Eclipse) after being repaired with two different materials. MATERIALS AND METHODS. Two repair groups and a control group consisting of 10 specimens each were generated. The ES group was repaired with auto-polymerizing polymer. The EE group was repaired with the Eclipse. The E group was left intact as a control group. A 3-point bending test device which was set to travel at a crosshead speed of 5 mm/min was used. Specimens were loaded until fracture occurred and the mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations were calculated for each group and the data were statistically analyzed. The results were assessed at a significance level of P<.05. RESULTS. The mean "displacement", "maximum load before fracture", flexural strength" and "flexural modulus" rates of Group E were statistically significant higher than those of Groups ES and EE, but no significant difference (P>.05) was found between the mean values of Group ES and EE. There was a statistically significant positive relation (P<.01) between the displacement and maximum load of Group ES (99.5%), Group EE (94.3%) and Group E (84.4%). CONCLUSION. The more economic and commonly used self-curing acrylic resin can be recommended as an alternative repair material for Eclipse denture bases.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼