RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Fire research in Sweden for 1997-99

        Arvidsson,Tommy 한국화재소방학회 1997 한국화재소방학회 학술대회 논문집 Vol.1997 No.-

        The Swedish Fire Research Board was established in 1979 to initiate and fund relevant fire research efforts. The Board is responsible for a long term research programme revised every third year, and the Board is one of two major Swedish sponsors of all fire research. Beside the Board we also have the Swedish National Rescue Services, funded by the government. BRANDFORSK gives very high priority for the industry and the insurance company and the need they express for fire research. Research that the Rescue Services Board are funding is mainly focusing the need for the fire department. The Swedish Fire Research Board, BRANDFORSK, is the joint agency of the Swedish government, the insurance industry and the business sector, for the initiation, funding and supervision of different kinds of fire research. Work is directed by a Programme Board and is performed in the form of projects at universities, research institutes, state authorities and private firms. The Secretariat of BRANDFORSK shares the premises of the Swedish Fire Protection Association, SFPA, and the SFPA is the principal and the party which enters into agreement with the State. The programme for the period 1997-1999 has been drawn up on the basis of both damage development and the trends in society which can be noted, and the evident fire problems of the interested parties and their need for fire research. The inputs in the programme have been broken down seven problem areas. In every problem area different project areas are set out, and these primarily specify the aim of the work. Our seven problem-areas are; Costs and benefits of fire protection measure. The role and behaviour of people and organizations Fire In buildings Fire in underground facilities Rescue operations fire in industries Fire and the environment. In comparison with previous fire research programmes, cost/benefit studies have been accorded higher priority, and this is also reflected in other problem areas. Grater Emphasis

      • An in vitro comparison of possibly bioactive titanium implant surfaces

        ,ransson, A.,Arvidsson, A.,Currie, F.,Franke-Stenport, V.,Kjellin, P.,Mustafa, K.,Sul, Y. T.,Wennerberg, A. Wiley Subscription Services, Inc., A Wiley Company 2009 Journal of biomedical materials research. Part A Vol.a88 No.4

        <P>The aim of the study was to compare Ca and P formation (CaP) and subsequent bone cell response of a blasted and four different possibly bioactive commercially pure (cp) titanium surfaces; 1. Fluoride etched (Fluoride), 2. Alkali-heat treated (AH), 3. Magnesium ion incorporated anodized (TiMgO), and 4. Nano HA coated and heat treated (nano HA) in vitro. Furthermore, to evaluate the significance of the SBF formed CaP coat on bone cell response. The surfaces were characterized by Optical Interferometry, Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). CaP formation was evaluated after 12, 24 and 72 h in simulated body fluid (SBF). Primary human mandibular osteoblast-like cells were cultured on the various surfaces subjected to SBF for 72 h. Cellular attachment, differentiation (osteocalcin) and protein production (TGF-β<SUB>1</SUB>) was evaluated after 3 h and 10 days respectively. Despite different morphological appearances, the roughness of the differently modified surfaces was similar. The possibly bioactive surfaces gave rise to an earlier CaP formation than the blasted surface, however, after 72 h the blasted surface demonstrated increased CaP formation compared to the possibly bioactive surfaces. Subsequent bone cell attachment was correlated to neither surface roughness nor the amount of formed CaP after SBF treatment. In contrast, osteocalcin and TGF-β<SUB>1</SUB> production were largely correlated to the amount of CaP formed on the surfaces. However, bone response (cell attachment, osteocalcin and TGF-F production) on the blasted controls were similar or increased compared to the SBF treated fluoridated, AH and TiMgO surface. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009</P>

      • KCI등재

        Assessments of Physical Workload in Sonography Tasks Using Inclinometry, Goniometry, and Electromyography

        Jenny Gremark Simonsen,Camilla Dahlqvist,Henrik Enquist,Catarina Nordander,Anna Axmon,Inger Arvidsson 한국산업안전보건공단 산업안전보건연구원 2018 Safety and health at work Vol.9 No.3

        Background: Echocardiography involves strenuous postures of the upper limbs. This study explored the physical workload in the neck and upper limbs in sonographers performing echocardiography, and the extent to which the workload differs from than in other work tasks (other sonographic examinations, and nonsonographic tasks). Methods: The physical load was assessed by inclinometry, goniometry, and electromyography methods in 33 female sonographers during authentic work using three different echocardiography techniques and other work tasks. Results: Echocardiography was characterized by low velocities of the head, arms, and wrists, and a low proportion of muscular resting time in the forearms, in the transducer limb, and the computer limb. The transducer limb was more elevated in one of the techniques, but this technique also involved a higher proportion of muscular resting time of the trapezius muscle. We also found a high proportion of awkward wrist postures in the transducer wrist in all three techniques; in one due to prolonged flexion, and in the others due to prolonged extension. Other work tasks were less static, and were performed with higher upper arm and wrist velocities. Conclusion: None of the three echocardiography techniques was optimal concerning physical workload. Thus, to achieve more variation in physical load we recommend that the equipment be arranged so that the sonographer can alternate between two different techniques during the workday. We also propose alternation between echocardiography and nonsonographic tasks, in order to introduce variation in the physical workload. Clinical expertise should be used to achieve further improvements.

      • SCOPUSKCI등재

        Assessments of Physical Workload in Sonography Tasks Using Inclinometry, Goniometry, and Electromyography

        Simonsen, Jenny Gremark,Dahlqvist, Camilla,Enquist, Henrik,Nordander, Catarina,Axmon, Anna,Arvidsson, Inger Occupational Safety and Health Research Institute 2018 Safety and health at work Vol.9 No.3

        Background: Echocardiography involves strenuous postures of the upper limbs. This study explored the physical workload in the neck and upper limbs in sonographers performing echocardiography, and the extent to which the workload differs from than in other work tasks (other sonographic examinations, and nonsonographic tasks). Methods: The physical load was assessed by inclinometry, goniometry, and electromyography methods in 33 female sonographers during authentic work using three different echocardiography techniques and other work tasks. Results: Echocardiography was characterized by low velocities of the head, arms, and wrists, and a low proportion of muscular resting time in the forearms, in the transducer limb, and the computer limb. The transducer limb was more elevated in one of the techniques, but this technique also involved a higher proportion of muscular resting time of the trapezius muscle. We also found a high proportion of awkward wrist postures in the transducer wrist in all three techniques; in one due to prolonged flexion, and in the others due to prolonged extension. Other work tasks were less static, and were performed with higher upper arm and wrist velocities. Conclusion: None of the three echocardiography techniques was optimal concerning physical workload. Thus, to achieve more variation in physical load we recommend that the equipment be arranged so that the sonographer can alternate between two different techniques during the workday. We also propose alternation between echocardiography and nonsonographic tasks, in order to introduce variation in the physical workload. Clinical expertise should be used to achieve further improvements.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼