http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
HVPE 법을 활용한 GaN 성장 시 질화처리에 관한 연구
이승훈,이주형,이희애,오누리,이성철,강효상,이성국,양재득,박재화,Lee, Seung Hoon,Lee, Joo Hyung,Lee, Hee Ae,Oh, Nuri,Yi, Sung Chul,Kang, Hyo Sang,Lee, Seong Kuk,Yang, Jae Duk,Park, Jae Hwa 한국결정성장학회 2019 한국결정성장학회지 Vol.29 No.4
HVPE is one of the GaN single crystal manufacturing methods which has been commercially widely used due to its high growth rate. HVPE method consists of a number of processes, in particular the nitridation of the substrate prior to GaN growth has a significant effect on the crystalline quality of the manufactured GaN single crystal. In this study, we investigated the effect of nitridation for crystalline quality of GaN when it was grown on the sapphire substrate. The whole growth conditions except for the nitridation process were the same, and the gas flow rate supplied to the sapphire substrate was variously changed during the nitridation. Here, we examined the effect of nitridation via the surface characterization of GaN single crystal grown by HVPE. HVPE는 GaN 단결정의 제조 방법 중 하나로 빠른 성장 속도가 장점인 상업적으로 널리 사용되는 성장 방법이다. HVPE 법에 의한 GaN 단결정 성장은 여러 공정으로 이루어지며, 특히 GaN 성장 전 기판의 질화 처리는 성장되는 GaN 단결정 품질에 상당한 영향을 미친다. 본 연구에서는 사파이어 기판 위에 GaN 단결정 성장 시 기판의 질화처리가 성장되는 GaN 단결정 품질에 미치는 영향을 알아보고자 하였다. 질화 처리를 제외한 다른 성장 조건은 동일하게 하였고 질화처리 시 기판에 공급되는 가스 유량을 다양하게 변화시킨 후 GaN 박막을 성장시키고, 성장된 GaN의 표면 특성평가를 통하여, HVPE 법에서의 질화처리 효과를 고찰하여 보고자 하였다.
이승훈,우유미,이성락,구교진,현창택,홍태훈,Lee, Seung-Hoon,Woo, Yu-Mi,Lee, Sung-Rak,Koo, Kyo-Jin,Hyun, Chang-Taek,Hong, Tae-Hoon 한국건설관리학회 2006 건설관리 : 한국건설관리학회 학회지 Vol.7 No.6
사회기반시설의 노후화에 따라 시설물 유지관리에 관한 관심이 증대되고 있으며, 이에 따라 다양한 사회기반시설에 대한 LCC분석 연구가 수행되고 있다. 특히 기계설비가 다수 포함된 기반시설에서는 시설물의 건설비와 더불어 보수/교체비, 에너지비 등 유지관리비용이 높은 비중을 차지하고 있다. 이에 본 연구에서는 하수처리장의 슬러지 수집기 선정에 있어 정량적 요소와 정성적 요소를 모두 고려하는 LCC 분석 모델을 개발하고, 사례적용을 통하여 최적대안을 선정하고자 한다. 문헌고찰과 분석대상 하수처리장의 슬러지 수집기에 대한 공사비와 유지관리 및 보수/교체 이력자료를 바탕으로 비용항목을 도출한다. LCC분석을 위한 가정사항 설정 후, 각 항목별 실적자료와 장비납품업체의 정보를 활용하여 경제성 평가결과를 도출하고, 할인율과 초기투자비 및 유지관리비의 비용변동범위에 따른 민감도분석을 실시한다. 설계자, 자재공급업체 및 시공전문가의 면담을 통하여 유지관리 편의성, 조달 용이성, 슬러지 수집 성능, 침전물제거 효율도, 환경친화성 등 슬러지 수집기 선정을 위한 기술적 사회적 영향인자를 파악한다. 분석된 기술적 사회적 요인과 LCC 분석결과인 경제성에 대하여 각 항목별 쌍별비교를 통하여 항목별 가중치를 설정하고 전문가 평가를 통하여 종합적인 최적안을 선정한다. This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.
이승훈,구교진,현창택,Lee Seung-Hoon,Koo Kyo-Jin,Hyun Chang-Taek 한국건설관리학회 2005 건설관리 : 한국건설관리학회 학회지 Vol.6 No.3
본 연구는 설계초기단계에 적합한 VE 적용방안을 제안하고자 하였다. VE방법론은 설계단계 초기에 적용할 경우 더욱 효과적이므로 본 연구는 설계 프로세스 초기단계의 설계YE에 초점을 맞추고 있다. 관련 연구문헌의 고찰과 실무경험을 바탕으로 국내 건설산업에서 설계VE의 문제점을 도출하였다. 이러한 문제점을 해결하기 위하여 본 연구는 (1)설계단계별 VE실시시기를 구분하고, (2)건설산업에 적합한 VE대상선정 방법을 제안하며, (3)기능분석 프로세스를 보다 합리적이고 실용적으로 개선함으로써 (4)전체 설계VE 수행절차를 효율적으로 개선하고자 하였다. The purpose of this study is to present proper VE application methods to euly design phases. Since VE methodology is more effective on early stage of design phase, the study focused on application of VE methodology in early stage of design process. With the examination of past studies, obstacles of VE application in domestic construction industry are defined. To solve these problems, this paper presents (1) subdivision of VE execution time, (2) an appropriate VE targeting method for construction industry, (3) a resonable and practical function analysis process, and (4) modified design-VE job plan.
CMOS 이미지 센서용 NMOS-Diode eFuse OTP 설계
이승훈,하판봉,김영희,Lee, Seung-Hoon,Ha, Pan-Bong,Kim, Young-Hee 한국정보통신학회 2016 한국정보통신학회논문지 Vol.20 No.2
본 논문에서는 프로그램 선택 소자는 채널 폭이 큰 NMOS (N-channel MOSFET) 트랜지스터 대신 DNW (Deep N-Well) 안에 형성된 채널 폭이 작은 isolated NMOS 트랜지스터의 body인 PW (P-Well)과 source 노드인 n+ diffusion 영역 사이에 형성된 기생하는 접합 다이오드를 사용하는 NMOS-Diode eFuse OTP (One-Time Programmable) 셀을 제안하였다. 제안된 eFuse OTP 셀은 프로그램 모드에서 NMOS 트랜지스터에 형성되는 기생하는 접합 다이오드를 이용하여 eFuse를 blowing 시킨다. 그리고 읽기 모드에서는 접합 다이오드를 이용하는 것이 아니고 NMOS 트랜지스터를 이용하기 때문에 다이오드의 contact voltage 강하를 제거할 수 있으므로 '0' 데이터에 대한 센싱불량을 제거할 수 있다. 또한 읽기 모드에서 채널 폭이 작은 NMOS 트랜지스터를 이용하여 BL에 전압을 전달하므로 OTP 셀의 blowing되지 않은 eFuse를, 통해 흐르는 읽기 전류를 $100{\mu}A$ 이내로 억제하여 blowing되지 않은 eFuse가 blowing되는 문제를 해결할 수 있다. In this paper, an NMOS-diode eFuse OTP (One-Time Programmable) memory cell is proposed using a parasitic junction diode formed between a PW (P-Well), a body of an isolated NMOS (N-channel MOSFET) transistor with the small channel width, and an n+ diffusion, a source node, in a DNW (Deep N-Well) instead of an NMOS transistor with the big channel width as a program select device. Blowing of the proposed cell is done through the parasitic junction formed in the NMOS transistor in the program mode. Sensing failures of '0' data are removed because of removed contact voltage drop of a diode since a NMOS transistor is used instead of the junction diode in the read mode. In addition, a problem of being blown for a non-blown eFuse from a read current through the corresponding eFuse OTP cell is solved by limiting the read current to less than $100{\mu}A$ since a voltage is transferred to BL by using an NMOS transistor with the small channel width in the read mode.
이산화탄소 증가가 습지토양의 탈질세균 군집구조에 미치는 영향
이승훈,김선영,강호정,Lee Seung-Hoon,Kim Seonyoung,Kang Hojeong 한국미생물학회 2004 미생물학회지 Vol.40 No.3
이산화탄소 농도의 증가가 습지토양의 탈질세균 군집구조에 미치는 영향을 살펴보기 위하여 자연농도 (370 ppm)와 고농도 (740 ppm)의 이산화탄소조건의 습지생태계를 조성하여 110일 이상 배양한 후 토양 내 미생물 군집구조의 변화양상을 관찰하였다. 미생물 군집군조 분석은 탈질과정에 관여하는 효소중하나인 nitrite reductase의 유전자인 nirS 유전자를 대상으로 polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) 분석기법을 이용하여 수행하였다. PCR 결과 모든 토양시료에서 nirS 유전자가 검출되었고, RFLP분석을 통해 자연농도의 이산화탄소조건에서 83개, 고농도 조건에서 95개의 phylotype을 획득하여 조성된 습지토양에서 탈질과정이 광범위하게 일어날 수 있음을 확인할 수 있었다. 두 경우 모두 두 종류 (type 1과 type 2)의 phylotype의 우점하고 있었고, 고농도 조건의 탈질세균 군집의 풍부도가 저농도 조건에 비해 더 높고, phylotype의 종류가 현저하게 변화되는 경향을 확인하였다. 본 연구결과는 습지토양의 탈질세균 군집이 매우 다양한 종류로 이루어져 있고, 이산화탄소의 증가에도 큰 영향을 받지 않는 상당히 안정적인 우점 개체군이 존재하고 있는 반면, 전체 phylotype의 약 60%는 이산화탄소 증가에 따라 민감하게 변화함을 보여주었다. To investigate the effects of elevated $CO_2$ on the denitrifying bacterial community structure in a wetland soil, dynamics of bacterial community structure was explored in an artificial wetland ecosystem with one of three plant species (T. latifolia, S. lacustris, and 1. effusus) under two levels of $CO_2$(370 ppm or 740 ppm) after 110day incubation. For the analysis of bacterial community structure, functional genes such as nitrite reductase genes (nirS) were PCR-amplified followed by cloning of PCR products and screening by restriction fragment length polymorphism (RFLP). nirS gene fragments were amplified in all analyzed soil samples. Species richness estimated by the number of distinct phylotypes were 83 and 95 in the ambient $CO_2$ treatment and the elevated treatment, respectively. Two phylotypes (type 1 and type 2) were dominant in both of the treatments. Elevated $CO_2$ treatment increased species richness of denitrifying as well as changed a large proportion of denitrifier phylotypes compared to those of the ambient treatment. Overall, the data in this study suggested that the denitrifying communities in the wetland soil are diverse and that the richness of denitrifying bacterial community might be affected by elevated $CO_2$ treatment.
이승훈,김용만,김주형,김재준,Lee, Seung-Hoon,Kim, Yong-Man,Kim, Ju-Hyung,Kim, Jae-Junn 한국건축시공학회 2011 한국건축시공학회지 Vol.11 No.1
건설 공사의 궁극적인 목표는 주어진 공사를 요구된 공사기간내에 설계도서에 명시된 품질 기준을 만족시키면서 가장 경제적이고 안전하게 완성하는데 있다. 마감공사는 공종이 세분화되어 매우 다양하고 복잡한 구조를 가지고 있으며 적정 투입 시점에 대한 세부 공종별 기준이 없고, 선후행 작업간의 우선 순위의 정립의 필요성이 약한 것이 특징이다. 본 연구는 마감공사 작업지연을 최소화하기 위하여 마감공사 세부 공종별 작업지연 우선 순위를 선정하여 소요 공기에 맞추어 프로젝트를 완료할 수 있는 정보를 제공하는 것이 목적이다. 본 연구에서 마감공사를 습식공사와 기타 마감공사로 나누어 각 공종별 내역을 기반으로 중요도를 분류하고, 설문을 통해 설계자, 시공자, 협력업체의 작업지연 요인을 분석하여 최종 작업지연 우선 순위를 선정하여 계획 공사기간 내에 공동주택 프로젝트를 완료할 수 있는 정보를 제공하는데 목적이 있다. The ultimate goal of construction is to complete the given work in the most economical and safest way within the required construction period while meeting the quality standards specified in the design drawing. There are a few characteristics of finish work. First, executed in subdivided processes, finish work involves a very diverse and complex structure. Second, there are no criteria for each segmented process with regard to the appropriate time of input. Third, it is not very necessary to set priorities for lead and lag works. This study intends to provide information on the completion of a project in accordance with the required duration by setting priorities in the delay of each detailed process of finish work to minimize delay in finish work. In this study, finish work is divided into wet work and other types of finish work, and the importance of each process is classified based on the given details of each process. In addition, the study employs a survey to analyze delay factors of a designer, a constructor, and a supplier. Using the survey results, the study sets priorities in delay of final work to provide information on the completion of an apartment project within the planned construction period.
플라즈마 처리에 의한 폴리비닐리덴플로라이드 나노섬유의 젖음성
이승훈,장선호,소윤미,이헌수,양철민,윤중현,김찬,Lee, Seung-Hoon,Jang, Seon-Ho,So, Yun-Mi,Lee, Hun-Su,Yang, Cheol-Min,Yun, Jung-hyun,Kim, Chan 한국섬유공학회 2018 한국섬유공학회지 Vol.55 No.1
Poly(vinylidene fluoride) (PVDF) is a critical polymeric material used in the mass production and application of electrospun nanofibers, and is popular due to its excellent properties. However, electrospun PVDF nanofibers are very hydrophobic and possess low surface energies, limiting their broad application. In this work, we investigated practical methods for the hydrophobic surface modification of PVDF nanofibers using four techniques: radio-frequency (RF) and PIN-type atmospheric plasmas, planar inductively coupled plasma (ICP), and planar capacitively coupled plasma (CCP). The use of RF atmospheric plasma was ineffective under the experimental conditions used, while the PIN-type atmospheric plasma efficiently modified PVDF nanofiber surfaces locally. The application of planar CCP to PVDF nanofibers was more effective than planar ICP for the same experimental conditions. In particular, the water contact angles of samples treated with planar CCP for 600 s and 900 s were $25^{\circ}$ and $10^{\circ}$ respectively, and wettability improved. Analysis with FT-IR, XPS, and FE-SEM showed that the surface CF and CH hydrophobic groups were destroyed without damaging the PVDF nanofibers, and hydrophilic species such as C=O, OH, and COOH were formed. As a consequence, quantitative analysis of nanofiber chemical composition is necessary when treated by plasmas, providing insight into the correlation of specific property changes with processing conditions, and indicating precise research results and application examples.
6 MeV 전자선의 차폐물질 원자번호와 조사야 크기에 따른 선량변화 연구
이승훈,곽근탁,박주경,김양수,차석용,Lee, Seung Hoon,Kwak, Keun Tak,Park, Ju Kyeong,Gim, Yang Soo,Cha, Seok Yong 대한방사선치료학회 2013 대한방사선치료학회지 Vol.25 No.2
목 적: 본 연구에서 우리는 6 MeV 전자선의 조사야 확대에 따른 선량변화가 차폐물질 원자번호와 관계가 있음을 알아보고 그 영향인자를 분석 하고자 한다. 대상 및 방법: 먼저 평행평판형 전리함(Exradin P11)을 $25{\times}25cm^2$ 폴리스티렌 팬텀표면에 평탄하게 끼운다. 허용투과율 5% 두께의 알루미늄, 구리, 납 물질들을 팬텀 상단에 차폐시킨 후 조사야 $6{\times}6$, $10{\times}10$ 그리고 $20{\times}20cm^2$별로 측정하였다. 조사조건은 선원-표면간거리 100 cm에서 기준조사야인 $10{\times}10cm^2$에 6 MeV 전자선을 이용하여 100 cGy 조사하였다. 다음으로 MCNP (Monte Carlo N Particle Transport Code)를 이용하여 각 물질 통과 후 발생되는 광자수, 전자수, 그리고 축적에너지를 계산하였다. 결 과: 허용투과율 5% 두께에 대한 차폐물 종류에 따른 측정결과 조사야 $10{\times}10cm^2$을 기준으로 한 $6{\times}6cm^2$과 $20{\times}20cm^2$의 두께변화율은 알루미늄에서 각각 +0.06%와 -0.06%, 구리에서 각각 +0.13%와 -0.1%, 납에서 각각 -1.53%와 +1.92%였다. 계산결과 조사야 $10{\times}10cm^2$ 대비 $6{\times}6cm^2$, $20{\times}20cm^2$의 축적에너지는 차폐를 하지 않았을 경우 각각 -4.3%와 +4.85%, 알루미늄 사용 시 각각 -0.87%와 +6.93%, 구리 사용 시 각각 -2.46%와 +4.48%, 납 사용 시 각각 -4.16%와 +5.57%였다. 광자수의 경우 차폐를 하지 않았을 경우 각각 -8.95%와 +15.92%, 알루미늄 사용 시 각각 -15.56%와 +16.06%, 구리 사용시 각각 -12.27%와 +15.53%, 납 사용 시 각각 -12.36%와 +19.81%였다. 전자수의 경우 차폐를 하지 않았을 경우 각각 -3.92%와 +4.55%, 알루미늄 사용 시 각각 +0.59%와 +6.87%, 구리 사용 시 각각 -1.59%와 +3.86%, 납 사용 시 각각 -5.15%와 +4.00%였다. 결 론: 본 연구로 조사야 증가함에 따른 차폐물 두께가 저 원자번호에서 감소하며, 고 원자번호에서는 증가함을 볼 수 있었으며, 계산을 통해 저 원자번호물질에서는 저지방사선, 고 원자번호물질에서는 산란전자가 영향을 주는 것을 알 수 있었다. Purpose: In this study, we analyzed how the dose change by field size effects on atomic number of shielding materials while using 6 MeV election beam. Materials and Methods: The parallel plate chamber is mounted in $25{\times}25cm^2$ the phantom such that the entrance window of the detector is flush with the phantom surface. phantom was covered laterally with aluminum, copper and lead which thickness have 5% of allowable transmission and then the doses were measured in field size $6{\times}6$, $10{\times}10$ and $20{\times}20cm^2$ respectively. 100 cGy was irradiated using 6 MeV electron beam and SSD (Source Surface Distance) was 100 cm with $10{\times}10cm^2$ field size. To calculate the photon flux, electron flux and Energy deposition produced after pass materals respectively, MCNPX code was used. Results: The results according to the various shielding materials which have 5% of allowable transmission are as in the following. Thickness change rate with field size of $6{\times}6cm^2$ and $20{\times}20cm^2$ that compared to the field size of $10{\times}10cm^2$ found to be +0.06% and -0.06% with aluminum, +0.13% and -0.1% with copper, -1.53% and +1.92% with lead respectively. Compare to the field size $10{\times}10cm^2$, energy deposition for $6{\times}6cm^2$ and $20{\times}20cm^2$ had -4.3% and +4.85% respectively without shielding material. With aluminum it had -0.87% and +6.93% respectively and with lead it had -4.16% and +5.57% respectively. When it comes to photon flux with $6{\times}6cm^2$ and $20{\times}20cm^2$ of field sizes the chance -8.95% and +15.92% without shielding material respectively, with aluminum the number -15.56% and +16.06% respectively and with copper the chance -12.27% and +15.53% respectively, with lead the number +12.36% and -19.81% respectively. In case of electron flux in the same condition, the number -3.92% and +4.55% respectively without shielding material respectively, with aluminum the number +0.59% and +6.87% respectively, with copper the number -1.59% and +3.86% respectively, with lead the chance -5.15% and +4.00% respectively. Conclusion: In this study, we found that the required thickness of the shielding materials got thinner with low atomic number substance as the irradiation field is increasing. On the other hand, with high atomic number substance the required thickness had increased. In addition, bremsstrahlung radiation have an influence on low atomic number materials and high atomic number materials are effected by scattered electrons.
이승훈,이선영,김양수,양명식,차석용,Lee, seung hoon,Lee, sun young,Gim, yang soo,Kwak, Keun tak,Yang, myung sik,Cha, seok yong 대한방사선치료학회 2015 대한방사선치료학회지 Vol.27 No.2
목 적 : 고주파 온열치료 시 약물투여 및 혈액채취에 사용되는 케모포트로 인한 열적 변화를 알아보고자 한다. 대상 및 방법 : 전극 크기 20 cm인 고주파 온열치료기(EHY-2000, Oncotherm Kft, Hungary)를 이용하여 현재 본원에서 사용 중인 케모포트 중 재질이 플라스틱인 소재, 티타늄을 둘러싼 에폭시 소재와 티타늄 소재 케모포트를 자체 제작한 직경 20 cm, 높이 20 cm 원통형 한천(Agar)팬텀에 삽입하여 온도를 측정하였다. 온도측정기(TM-100, Oncotherm Kft, Hungary) 그리고 Sim4Life(Ver2.0, ZMT, Zurich, Switzerland) 프로그램을 사용하여 실제 측정된 온도변화와 비교 분석하였다. 측정위치는 전극 중심축 및 중심축 측면 1.5 cm지점에 각각 0 cm(표면), 0.5 cm, 1.8 cm, 2.8 cm 깊이별로 하였다. 측정조건은 온도 $24.5{\sim}25.5^{\circ}C$, 습도 30 ~ 32%, 출력 전력 100 W로 5분 간격으로 총 60분을 측정 하였다. 결 과 : 케모포트 미사용, 플라스틱, 에폭시 그리고 티타늄 케모포트를 사용한 경우의 최고온도는 전극 중심축 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$와 모의실험값 $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$이며, 전극 중심축 1.5 cm 측면 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$와 모의실험값 $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$이다. 고안 및 결론 : 고주파 전자기장에 의한 케모포트 주위의 열적 변화량은 부도체 물질인 플라스틱과 에폭시 소재에서 미사용의 경우보다 낮게 나타났으며, 도체 물질인 티타늄 케모포트에서는 약간의 차이를 보였다. 이는 케모포트내 금속 함유량 및 기하학적 구조에 의한 것과 이용 장비의 낮은 고주파 대역를 사용함에 있는 것으로 여겨진다. 즉 본 연구에 사용된 케모포트는 열 변화가 미미하여 장해를 고려하지 않아도 된다고 사료된다. Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.