http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
우라늄 제거를 위한 실험실 규모 동전기 장치의 개선 방안
박혜민,김계남,김승수,김완석,박욱량,문제권,Park, Hye-Min,Kim, Gye-Nam,Kim, Seung-Soo,Kim, Wan-Suk,Park, Uk-Ryang,Moon, Jei-Kwon 한국방사성폐기물학회 2013 방사성폐기물학회지 Vol.11 No.2
The original pilot-scale electrokinetic equipment suitable to soil contamination characteristics of Korean nuclear facility sites was manufactured for the remediation of soil contaminated with uranium. During the experiment with the original electrokinetic equipment, many metal oxides were generated and were stuck on the cathode plate. The uranium removal capability of the original electrokinrtic equipment was almost exhausted because the cathode plate covered with metal oxides did not conduct electricity in the original electrokinetic equipment. Therefore, the original electrokinetic equipment was improved. After the remediation experience for 25 days using the improved electrokinetic remediation equipment, the removal efficiency of uranium from the soil was 96.8% and its residual uranium concentration was 0.81 Bq/g. When the initial uranium concentration of soil was about 50 Bq/g, the electrokinetic remediation time required to remediate the uranium concentration below clearance concentration of 1.0 Bq/g was about 34 days. When the initial uranium concentration of soil was about 75 Bq/g, the electrokinetic remediation time required to remediate below 1.0 Bq/g was about 42 days. When the initial uranium concentration of soil was about 100 Bq/g, the electrokinetic remediation time required to remediate below 1.0 Bq/g was about 49 days. 방사능 오염 토양 복원을 위해 실험실 규모의 동전기 복원장치를 제작하여 가동 하던 중 토양 내 존재하던 금속이온의 용출로 금속 산화물이 발생하여 음극의 전류 흐름을 차단하는 문제가 발생하였다. 전류의 차단으로 토양 내 우라늄 제거 능력이 상실되어 이러한 문제를 해결하는 해결 방안을 모색하여 개선된 동전기 복원 장치를 제작하였다. 개선된 실험실 규모 동전기 복원 장치를 이용하여 토양복원 실험을 25 일간 수행 하였을 때 우라늄 잔류 농도는 0.81 Bq/g으로 약 96.8%의 제거 효율을 보였으며, 초기 우라늄 농도 50 Bq/g 일 때 우라늄 규제 해제 농도인 1 Bq/g 이하로 제거 되기 까지는 34 일의 복원 기간이 필요하고, 초기 우라늄 농도 75 Bq/g, 100 Bq/g 일 때 각 42 일, 49 일이 필요한 것으로 나타났다.
진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구
박혜민(Hye-Min Park),윤용수(Yong-Su Yoon),김은혜(Eun-Hye Kim),정회원(Hoi-Woun Jeong),김정수(Jung-Su Kim) 대한방사선과학회(구 대한방사선기술학회) 2021 방사선기술과학 Vol.44 No.6
The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.