http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
최근호,Keun Ho Choi 한국화학공학회 2023 Korean Chemical Engineering Research(HWAHAK KONGHA Vol.61 No.3
A mathematical model for predicting the liquid circulation velocity in an airlift reactor was developed based on the mechanical energy balance of the fluid circulation loop. The model considered the energy loss due to a 90° turn, the energy loss due to friction, and the energy loss due to the change in cross-sectional area at each part of the reactor. The model that separately considered the loss coefficients related to friction, direction change, and cross-sectional area change was able to predict the liquid circulation velocity better than the previous model using lumped parameters. The liquid circulation velocity was measured by the tracer pulse method. Most of our experimental results obtained in external-loop airlift reactors, which had the top and bottom connecting pipes, as well as other investigators' results obtained in various types of airlift reactors, were well predicted by the developed model with an error within 20%. Useful empirical equations for the loss coefficient related to the 90° turn of the circulating fluid were obtained in external and internal-loop airlift reactors and used to predict the liquid circulation velocity.
다차원 도시시설물 관리를 위한 멀티 텍스처 기법과 다중 스레드 기법의 적용에 관한 연구
최근호,강병준,조홍범,김원철,Choi, Keun-Ho,Kang, Byoung-Jun,Cho, Hong-Beom,Kim, Won-Cheol 한국공간정보학회 2010 한국공간정보학회지 Vol.18 No.1
최근까지 도시시설물 관리를 위해 활용된 GIS 기술은 주로 2차원 기반의 GIS 기술이었다. 하지만 도시시설물은 3차원 공간상에 존재하며 이를 2차원으로 추상화시키면 정보의 손실이 일어나게 된다. 또한 도시 공간 내에 점차 시설물의 수가 증가하고 있고 대부분의 도시시설물이 지하공간에 위치하기 때문에 2차원 기반의 시스템에서 도시 내 모든 시설물의 정보를 통시에 파악하고 관리하는 것이 어려워지고 있다 본 논문에서는 멀티 텍스처 기법을 이용한 다차원 도시시설물 관리 시스템을 제안한다. 제안된 시스템은 3차원 상에서 도시시설물을 가시화하여 데이터의 손실을 줄이고 정보의 가독성을 높이며, 2차원 벡터 데이터의 3차원 라스터 변환을 통한 가시화 기법을 개발하여 다양한 2차원 GIS 의 공간분석 결과를 3차원 데이터와 동시에 활용할 수 있도록 한다. 또한 3차원 데이터를 처리하는 경우에 시스템의 속도 및 성능이 저하되어 활용 효율성이 떨어지는 문제를 해결하기 위하여 다중 스레드 프로세스를 적용하였다. 본 논문에서 제안한 기술은 기존에 텍스처를 통해 보여주던 센서의 상태정보를 3차원 영상, 시설물 데이터와 함께 시각정보로 표출함으로써 직관적인 시설물 모니터링이 가능해졌다는데 의의가 있다. Recently, 2D GIS technology is applied for urban facility management. However, urban facilities are located in 3D space and the information loss is occurring during data abstraction from 3D urban facility to 2D object. Also, the number of urban facilities is increasing steadily and most of urban facilities are located in underground space in the city. Therefore 2D urban facility management system has a limitation on visualization and management for a large number of urban facilities. In this paper, a multi-dimensions urban facility management system based on multi-texture technology is proposed. The proposed system reduces the information loss and improves the readability of information by visualizing urban facilities on 3D virtual space. A multi-texturing technology is applied for integrating of 2D vector data and 3D raster data, and a multi-thread technology is used for improving speed and performance of the system. The proposed technology can be used as a guideline for urban facility monitoring as providing visual information of a facility status with 3D image and facility data.
최근호 ( Keun Ho Choi ) 한국화학공학회 2020 Korean Chemical Engineering Research(HWAHAK KONGHA Vol.58 No.4
외부순환형 공기부양반응기에서 낮은 주파수의 압력 변동에 대해 연구하였다. 상승관과 하강관의 상부와 하부에 설치된 내압관의 액면을 휴대폰으로 촬영하는 방법으로 빠른 주파수의 변동이 제거된 압력을 측정하였다. 자기상관함수와 교차상관함수의 계산을 통해 압력의 주기적인 변동을 확인하였다. 기체속도가 일정하여도 순환액체의 관성으로 인해 압력은 물론이고 상승관과 하강관내의 기체체류량도 주기적으로 변동하였다. 일반적으로 기체유속이 증가할수록 압력 변동의 강도는 커졌다. 비분산 액체높이가 0.04 m일 때 압력 변동의 주기는 기체속도가 0.14 ms<sup>-1</sup>에서 극대값을 보여주었다. 이는 기체속도가 커질수록 순환 액체속도의 증가율은 둔화하고 효과적으로 순환하는 액체의 부피가 감소하므로 순환액체의 관성이 극대값을 보이기 때문이다. Low-frequency pressure fluctuations in an external-loop airlift reactor were investigated. Low-frequency pressure fluctuations could be measured by shooting videos about liquid levels in the four piezometric tubes which were installed at the lower and upper parts of the riser and downcomer using a cellular phone. The periodic characteristics of pressure fluctuations were proved by the calculation of their auto-correlation function and cross-correlation function. Even if the riser superficial gas velocity was constant, the riser and downcomer gas holdups as well as wall pressures were periodically changed due to the inertia of circulating liquid. In general, the intensity of pressure fluctuations increased with an increase in the gas velocity. When the unaerated liquid height was 0.04 m, the maximum period of pressure fluctuations was found at the specific gas velocity (0.14 ms<sup>-1</sup>). It was because the maximum inertia of circulating liquid resulted from a reduction in the increasing rate of the liquid circulation velocity and a decrease in the volume of the effectively circulating liquid with an increase in the gas velocity.