http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
주거건물용 이중외피 시스템의 열성능 평가에 관한 실험적 연구
조구상(Joe, Goo-Sang),김지혜(Kim, Ji-Hye),여명석(Yeo, Myoung-Souk),김광우(Kim, Kwang-Woo) 대한건축학회 2014 대한건축학회논문집 Vol.30 No.11
The objective of this study is to evaluate thermal performance of suggested double skin facade by comparing with conventional facade. The evaluation was performed by experiments of conventional facade and double skin facade through the extreme conditions. For evaluation of thermal performance, peak cooling load and peak heating load is measured. For this measurement, ceiling, floor, all the walls are adiabatic condition except for the location of building facade. And to keep the constant indoor temperature, air is supplied through AHU. In the process of evaluation on thermal performance, outdoor temperatures is applied maximum temperature of daytime in summer condition and minimum temperature of nighttime in winter condition using Seoul weather data. Indoor temperature is used Recommended temperature of energy conservation code in Korea. And according to the survey, Maximum vertical solar radiation during the daytime is applied. As a results, Double skin facade could reduce peak cooling load by 60% or more than conventional facade during summer peak condition. And the operation of double skin facade during winter peak condition also could reduce peak heating load by 30% or more than operating conventional facade.
천장복사난방시스템이 적용된 사무소 건물에서의 downdraft 평가
조구상(Joe, Goo-Sang),김동우(Kim, Dong-Woo),정웅준(Chung, Woong-June),성욱주(Seong, Uk-Joo),여명석(Yeo, Myoung-Souk) 한국건축친환경설비학회 2018 한국건축친환경설비학회 논문집 Vol.12 No.4
Radiant ceiling heating system radiates heat to the surrounding surfaces including the cold interior surface of the window. The cold window surface, without heating system, loses heat via transmission to the cold outside. It can be caused thermal discomfort by downdraft. Downdraft is unwanted local cooling of the body caused by air movement. Therefore it is more likely to occur when air temperature is lower and air velocity is higher. The objective of this study is to find out the appropriate conditions of radiant ceiling heating system to prevent thermal discomfort by analyzing the indoor air temperature and air velocity distribution in office space. A computational model of a room with radiant ceiling heating system is constructed within the CFD program Star CCM+. Six cases of radiant ceiling heating system with varying surface temperatures, surface areas and window U-value are considered.
실험장비를 이용한 통기성 외피의 단열성능평가 방법에 관한 연구
조구상(Joe Goo-Sang),박상훈(Park Sang-Hoon),조가영(Cho Ga-Young),이선우(Lee Sun-Woo),여명석(Yeo Myung-Seok),김광우(Kim Kwang-Woo) 한국건축친환경설비학회 2007 한국건축친환경설비학회 학술발표대회 논문집 Vol.- No.-
The purpose of this study is to show that experimental method to evaluate performance of ventilated envelope. To do this, a factor that influence on performance of ventilated envelope like cavity's airflow, materials of envelope etc is analyzed. And analyzed factor is applied to the element of experimental equipment to evaluate performance of ventilated envelope. then, experimental equipment is developed and carried out experiment to suggest that method to performance of ventilated envelope by experimental equipment.
천장복사패널이 적용된 사무소 건물에서의 Downdraft 발생 저감 방법에 관한 연구
박소정(Park So-Jeong),조구상(Joe,Goo-Sang),신대욱(Shin Dae-Uk),이승재(Lee Seung-Jae),여명석(Yeo,Myoung-Souk),김광우(Kim Kwang-Woo) 한국건축친환경설비학회 2011 한국건축친환경설비학회 학술발표대회 논문집 Vol.2011 No.10
Recently, the glass area in office building has been increasing. In cold weather, downdraft that descending cold air induced by cold window causes thermal discomfort to occupants would be able to occur in perimeter zone. In order to prevent downdraft, separate heating systems are mainly installed near windows such as FCU. Warm air discharged from these systems leads the descending cold air to rise again. However in terms of space utilization, it would be disadvantageous because such systems take the space near window. Furthermore, the concentrated airflow created from diffuser can cause discomfort to the occupants. As an alternative to these conventional methods, radiant panel could be apply for preventing downdraft. In this study, to evaluate the possibility of downdraft in perimeter zone of office building, the prototype of office building was selected as a simulation model. It was evaluated by CFD for the possibility of downdraft, through the change of design factors such as area, surface temperature of radiant panel and thermal performance of window.
레지오넬라증 예방 지침을 위한 건축 분야 전문가의 역할 및 필요성
이준혜(June Hae Lee),이세진(Se Jin Lee),조구상(Goo Sang Joe),여명석(Myoung Souk Yeo),이기영(Ki young Lee) 대한설비공학회 2018 대한설비공학회 학술발표대회논문집 Vol.2018 No.6
국내에서의 레지오넬라증 감염 보고 건수는 매년 증가 추세에 있으며 레지오넬라균은 인공수계에서 증식이 활발하다. 그에 따라 건물 내의 수계 관련 시스템에서의 관리를 위해서는 건축적 지식을 바탕으로 관리방안이 제시되어야 한다. 본 논문에서는 국내 레지오넬라 관리 지침 개선을 위한 국내 건축 전문가들의 레지오넬라 관리 방안에 대한 역할 및 필요성을 서술하였다. 인공수계 시스템에서의 레지오넬라증 증식 및 전파 경로 영향 분석 결과 균 생장 억제를 위해서는 건축분야의 전문 지식이 요구된다. 국내외 레지오넬라 관리 지침의 비교 분석을 통하여 건축분야에서의 기술지침이 필요하다. 마지막으로 레지오넬라 예방지침 적용에는 건축물과 관련된 현행 규정과 상충되는 방안에 대한 조율 및 개선에 대한 건축 분야 전문가의 역할이 필요하다.
국내 건물에서의 레지오넬라 감염 예방을 위한 급탕설비의 계획 및 관리사례 고찰
이세진(Se Jin Lee),이준혜(June Hae Lee),조구상(Goo Sang Joe),여명석(Myoung Souk Yeo),이기영(Ki young Lee) 대한설비공학회 2018 대한설비공학회 학술발표대회논문집 Vol.2018 No.6
최근 레지오넬라 감염제어를 위한 국가적 노력이 계속되고 있음에도 불구하고, 국내 레지오넬라증 환자 수는 급등하고 있다. 2016년 전국 정기 모니터링 결과에 따르면 온천과 찜질방 및 대형목욕탕의 균검출율이 가장 높았다. 또한, 가정 내 감염이 적지 않음에도 불구하고 공동주택은 정기 모니터링 대상에 포함되어 있지 않아 해당 시설들에 대한 관련 대책 마련이 시급하다. 이에 따라 본 연구에서는 현장조사와 문헌조사를 통해 지침 및 제도 개선을 위한 기초자료를 제공하고자 하였다. 고찰결과 순환식 욕탕설비는 법규에 따른 시설검증 강화와 소독장치에 관한 세부지침 수립이 우선시되었다. 중앙집중식 급탕설비는 열소독 운전을 위한 세부 지침수립과 동시에 에너지를 고려한 운전전략 제안 및 대안장비의 개발·인증을 통한 다양한 해결책 마련이 요구된다.
HVAC 시스템 성능평가를 위한 시스템 구현방법에 관한 연구
이승재(Lee Seung-Jae),신대욱(Shin Dae-Uk),박소정(Park So-Jeong),조구상(Joe Goo-Sang),여명석(Yeo Myoung-Souk),김광우(Kim Kwang-Woo) 대한건축학회 2011 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.31 No.2(계획계)
In this study, a system of an experimental setup was investigated for HVAC system on laboratory experiment scale particularly. For the process for experimental setup, elements needed for the objective of experiment were analysed and the elements of the system were obtained. At this point, a study of system setup method to determine the experimental setup concerning relations among factors of the system was performed for which is applied it to a performance assesment. Through this study, it is systematized to classify ‘real system’ and ‘virtual system’ according to significance of the realization of experiment and justifies the way to determine the optimization method of performance assesment.