      • 농식품 환경 분야(PF) : PF-15 ; GC/ECD를 이용한 소고기, 닭고기, 우유 중 델타메쓰린 잔류 분석

        정다이 ( Da I Jung ),최정희 ( Jeong Heui Choi ),김성우 ( Sung Woo Kim ),임소정 ( So Jeong Im ),이영준 ( Young Jun Lee ),무스픽 ( Musfiqur Rahman ),압두 ( Abd El Aty ),심재한 ( Jae Han Shim ) 한국환경농학회 2014 한국환경농학회 학술대회집 Vol.2014 No.-

        In this study, a method was developed to determine deltamethrin residues in beef, chicken, and milk using gas chromatography equipped with electron capture detector. Samples were extracted with acetonitrile and MgSO4 and purified with SPE Florisil cartridge. Performance characteristics, including linearity, quantitation limit (LOQ), precision, and recovery were validated. A matrix-matched calibration was used for quantitation and recoveries obtained at 3 spiking levels; 15, 30, and 60 ㎍/kg, were satisfactory (74.8∼97.9 %). Precision and repeatability presented as relative standard deviation (RSDs) were < 8%. The limits of quantitation (LOQ) were estimated to be 10 ㎍/kg. The developed method was found to be able to determine the analyte with satisfactory intensity and accuracy in incurred samples.

      • 뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가

        이두상,강효석,최병준,박상준,정다이,이건호,안민우,전명수,Lee, Doo Sang,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Geon Ho,Ahn, Min Woo,Jeon, Myeong Soo 대한방사선치료학회 2018 대한방사선치료학회지 Vol.30 No.1

        목 적 : 뇌 정위적 방사선수술은 외과적 수술로 인한 합병증 발생 비율이 높은 질환을 비침습적으로 치료할 수 있다. 하지만 뇌 정위적 방사선수술은 방사선을 이용하기 때문에 분할방사선치료와 같이 방사선에 의한 부작용을 동반할 수 있다. 두경부 등의 분할방사선치료 시 방사선에 의한 부작용을 줄이기 위해 Coplanar Volumetric Modulated Arc Therapy(C-VMAT)와 Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT)가 주변 정상조직에 미치는 영향에 대한 분석이 이루어졌지만, 뇌 정위적 방사선수술에서는 이러한 내용들이 분석되지 않았다. 본 연구에서는 뇌 정위적 방사선수술을 실시한 환자를 대상으로 C-VMAT과 NC-VMAT을 비교, 분석하여 NC-VMAT의 유용성을 평가하고자 한다. 대상 및 방법 : 뇌 정위적 방사선수술 13건을 대상으로 하였으며, C-VMAT, NC-VMAT 치료 계획을 진행하였다. 치료 계획 용적은 최소 0.78 cc에서 최대 12.26 cc의 용적을 가지고 있었으며, 처방 선량은 15~24 Gy가 처방되었다. 치료 장비는 trueBEAM Stx(Varian Medical Systems, USA)을 사용하였으며, 치료 계획에 사용된 에너지는 6 MV Flattening Filter Free(6FFF) X-선을 이용하였다. C-VMAT 치료계획은 half 2 Arc 또는 full 2 Arc를 사용하여 치료계획을 진행했으며, NC-VMAT 치료계획은 $40{\sim}190^{\circ}$의 Arc를 3~7개 사용하고, couch의 각도 또한 3~7개의 각도로 구성하여 치료계획을 진행하였다. 결 과 : 최대선량의 평균 값은 C-VMAT에서 $105.1{\pm}1.37%$로 나타났으며, NC-VMAT에서는 $105.8{\pm}1.71%$로 나타났다. C-VMAT의 처방 선량 지수(Conformity index)는 $1.08{\pm}0.08$로 나타났고, 선량 균질 지수(Homogeneity Index)는 $1.03{\pm}0.01$로 나타났다. NC-VMAT의 처방 선량 균질지수는 $1.17{\pm}0.1$, 선량 균질지수는 $1.04{\pm}0.01$로 나타났다. 뇌의 $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$는 C-VMAT에서 $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$, $4.03{\pm}3.43cc$로 나타났으며, NC-VMAT에서는 $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$로 나타냈다. 결 론 : 최대선량과 처방 선량 지수, 선량 균질 지수 항목에서는 C-VMAT과 NC-VMAT이 큰 차이를 보이지는 않았다. 뇌의 선량 당 용적은 $V_2{\sim}V_{18}$까지 구간에서 값의 차이는 최소 0.5 %에서 최대 48 %의 차이가 나타냈다. $V_{19}{\sim}V_{24}$까지 구간에서 값의 차이는 최소 0.4 %에서 최대 4.8 %의 차이가 나타냈다. 방사선괴사(Radionecrosis)가 발생하기 시작하는 $V_{12}$ 용적의 평균 값을 비교해본 결과 NC-VMAT 이 C-VMAT 대비 약 12.2 % 적은 용적을 포함하는 것을 알 수 있었다. 이러한 결과로 볼 때 NC-VMAT 치료 계획을 수립한다면, $V_2{\sim}V_{18}$의 용적을 줄일 수 있기 때문에 방사선괴사를 줄일 수 있을 것이라 사료된다. Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

      • 정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가

        안민우,강효석,최병준,박상준,정다이,이건호,이두상,전명수,Ahn, Min Woo,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Geon Ho,Lee, Doo Sang,Jeon, Myeong Soo 대한방사선치료학회 2018 대한방사선치료학회지 Vol.30 No.1

        목 적 : 본 연구에서는 정위적체부방사선치료시 ExacTrac과 CBCT를 단계적으로 적용한 Combine IGRT를 사용하여 Set-up 오차를 비교 및 분석하여 Combine IGRT의 유용성을 평가하고자 한다. 대상 및 방법 : 2014년 5월에서 2017년 11월까지 본원에 내원하여 trueBEAM Stx(Varian medical System, USA)에서 정위적체부방사선치료를 받은 환자 중 부위별로 뇌(Brain) 3명, 척추(Spine) 9명, 골반(Pelvis) 3명으로 분류하였다. 치료전 ExacTrac을 사용하여 Lateral(Lat), Longitudinal(Lng), Vertical(Vrt) 방향과 Roll, Pitch, Yaw 방향으로 Set-up 오차를 보정하였고, ExacTrac 이동 값을 적용 후 CBCT를 추가적으로 수행하여 Lat, Lng, Vrt, Rotation(Rtn) 방향으로 보정하였다. 결 과 : ExacTrac 사용시 뇌 부위의 오차는 Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, 척추 부위는 Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, 골반 부위는 Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$로 나타났다. Couch 이동 후 CBCT를 하였을 때, 뇌 부위는 Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, 척추 부위는 Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, 골반 부위는 Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$ 오차가 발생하였다. 결 론 : 정위적체부방사선치료시 ExacTrac에 추가적으로 CBCT를 사용한 Combine IGRT의 경우는 ExacTrac만 사용한 경우보다 환자의 Set-up 오차를 줄일 수 있게 나타났다. 그러나 Combine IGRT를 적용함으로 환자 Set-up 확인시간, 영상획득을 위한 체내 흡수선량이 증가한다. 그러므로 환자 상황에 따라 Combine IGRT를 사용하여 환자의 Set-up 오차를 적게 함으로써 방사선치료 효과비를 증가시킬 수 있을 것으로 사료된다. Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

      • 유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰

        이건호,강효석,최병준,박상준,정다이,이두상,안민우,전명수,Lee, Geon Ho,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Du Sang,Ahn, Min Woo,Jeon, Myeong Soo 대한방사선치료학회 2019 대한방사선치료학회지 Vol.31 No.1

        목 적: 수술 후 유방암 환자의 1차 방사선치료 후 2차 방사선치료 시 단일전자선을 사용하는 것과 서로 다른 에너지의 전자선을 혼합하여 사용하는 방법에 대해 유용성을 평가하고자 한다. 대상 및 방법: 본 연구에서는 2018년 1월부터 10월까지 본원 유방암 방사선 치료 환자를 대상으로 하였으며, 혼합 전자선을 사용하여 2차 치료를 진행한 환자 59명 중 에너지 6 MeV, 9 MeV를 혼합 사용한 환자 40명(A그룹)과 9 MeV, 12 MeV를 혼합 사용한 환자 19명(B그룹)을 대상으로 진행하였다. 각 그룹의 환자마다 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV)와 9 MeV, 12 MeV, Combine(9 MeV / 12 MeV) 각기 다른 방법으로 세 가지 치료계획을 세우고, 원발병소에 전달되는 최대선량, D95, D5과 폐의 전달되는 최대선량, 평균선량, $V_3$, $V_5$, $V_{10}$을 비교 분석하였다. 결 과: A그룹 치료계획의 D95 평균값은 6 MeV에서 $785.33{\pm}225.37cGy$, 9 MeV에서 $1121.79{\pm}87.02cGy$, SUM(6 MeV / 9 MeV)에서 $1010.98{\pm}111.17cGy$였으며, 6 MeV / 9 MeV에서의 평균값이 처방 선량에 가장 적합했다. 치료하는 유방 방향의 폐의 저선량 영역 $V_3$,$V_5$의 평균값은 6 MeV / 9 MeV에서 $3.24{\pm}3.49%$, $0.72{\pm}1.55%$였고, 9 MeV에서 $7.25{\pm}4.59%$, $3.07{\pm}2.64%$로 가장 높은 값을 보였고, 6 MeV에서 $0.21{\pm}0.45%$, $0.03{\pm}0.07%$로 가장 낮은 값을 보였다. 폐의 최대선량과 평균선량은 6 MeV / 9 MeV에서 $727.78{\pm}137.27cGy$, $49.16{\pm}24.44cGy$였으며, 9 MeV에서 $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$로 가장 높았고, 6 MeV에서 $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$로 가장 낮았다. $V_{10}$의 값은 모두 0에 가까웠다. B그룹도 A그룹의 패턴으로 나타났다. 결 론: 폐의 $V_3$, $V_5$의 저선량 영역에서 상대적인 차이가 나타났으며, 혼합 에너지 적용 시 원발병소의 선량 전달에 있어서 가장 효과적임을 알 수 있었다. 유방암 추가 방사선 치료 시 전자선 에너지를 combine하여 사용하는 방법이 에너지 재원으로부터 제한되는 에너지의 효과를 좀 더 효과적으로 사용할 수 있는 방법이라고 사료되며 비록 작은 선량차이이기 때문에 간과하고 넘어갈 수 있는 부분들도 다시 한번 생각해본다면 조금 더 환자에게 도움이 되는 방사선 치료가 될 수 있을 것으로 사료된다. Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

      • 폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가

        이건호,강효석,최병준,박상준,정다이,이두상,안민우,전명수,Lee, Geon Ho,Kang, Hyo Seok,Choi, Byoung Joon,Park, Sang Jun,Jung, Da Ee,Lee, Du Sang,Ahn, Min Woo,Jeon, Myeong Soo 대한방사선치료학회 2017 대한방사선치료학회지 Vol.29 No.2

        Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs. 목 적: 폐에서 VMAT치료는 연속적으로 회전을 하면서 방사선을 조사하므로 정상적인 폐에 저 선량을 증가시킨다. 이로 인해 방사선 부작용 중 방사선 폐렴의 발생률이 증가 할 수 있다. 본 연구에서는 방사선 폐렴의 발생 확률 증가 원인이 되는 폐의 저 선량 영역의 방사선을 줄일 수 있는 H-VMAT 방법을 적용하여 치료를 받은 환자를 대상으로 치료계획별 폐의 저 선량 영역과 주변 정상장기들에 전달되는 방사선량을 비교 분석하여 H-VMAT의 유용성을 평가하고자 하였다. 대상 및 방법: 폐암방사선 치료 환자 중 H-VMAT 방법을 적용한 환자 25명을 대상으로 하였으며, 치료 계획용 용적의 처방선량은 총 선량 44 Gy를 22회 분할 조사로 적용하였다. 각 환자마다 Conventional RT, VMAT, H-VMAT 방법으로 계획을 진행하였다. Conventional RT는 치료계획용적의 크기, 위치, 모양 및 주변장기들의 위치를 고려하여 4~5개 조사야로 치료계획을 진행하였고, VMAT 치료계획의 경우는 $360^{\circ}$를 2번 회전하는 방법과 $180^{\circ}$를 2~3회 회전하는 방법으로 계획하였다. H-VMAT은 폐의 선량 및 주변 장기의 허용선량을 고려하여 VMAT 치료계획에서 2개의 고정조사야를 추가 하여 계획하였다. 결 과: 폐선량은 비소세포성폐암에서 치료계획용적을 제외한 폐의 $V_5$, $V_{10}$은 H-VMAT이 $55.40{\pm}13.39%$, $32.05{\pm}11.37%$로 가장 낮았고, 소세포성폐암에서도 $V_5$, $V_{10}$의 값은 $64.32{\pm}16.15%$, $35.50{\pm}9.91%$로 가장 낮았다. 비소세포성폐암에서 VMAT의 척수 선량은 $21.15{\pm}4.02Gy$로 다른 치료방법과 비교하여 최대 7.94 Gy 차이만큼 낮은 선량이 전달되었고, 소세포성폐암에서는 $19.72{\pm}1.82Gy$로 가장 낮은 선량을 보였다. 심장의 $V_{20}$은 H-VMAT와 VMAT의 비교 결과 VMAT이 최대 16.2 % 더 낮은 값을 보이기도 하였다. 식도에 전달되는 평균선량 역시 소세포성폐암과 비소세포성폐암에서 $17.44{\pm}2.04Gy$, $17.84{\pm}9.20Gy$로 VMAT이 가장 낮았다. 결 론: 주변 정상 장기 선량의 값을 비교해 보았을 때, VMAT에서는 심장, 식도, 척수 등에서 나머지 치료계획보다 더 적은 선량이 전달되는 것을 알 수 있었다. 하지만 척수를 제외한 나머지 장기에서는 H-VMAT과 큰 차이를 보이지 않았다. H-VMAT은 일부 정상 장기의 선량이 증가하였지만 허용선량을 초과하지 않았다. 그리고 폐의 $V_5$, $V_{10}$에서 낮은 값을 보였다. Conventional RT, VMAT, H-VMAT을 비교하였을 때 심장, 식도, 척수 등에 전달되는 선량이 부작용을 발생시킬 수 있는 선량보다 적다면 폐의 저 선량 영역의 장점을 보이는 H-VMAT 방법을 적용함으로써 방사선폐렴의 발생률을 낮출 수 있을 것이라고 사료된다.

      • 06 식품의약품안전처 SESSION : 국가 잔류농약 안전관리 연구 보고회 ; 조리가 쑥갓 중 diethofencarb와 부추 중 procymidone의 잔류양상 변화에 미치는 영향

        김성우 ( Sung Woo Kim ),최정희 ( Jeong Heui Choi ),정다이 ( Da I Jung ),임소정 ( So Jeong Im ),이영준 ( Young Jun Lee ),무스픽 ( Musfiqur Rahman ),압두 ( Abd El Aty ),심재한 ( Jae Han Shim ) 한국환경농학회 2014 한국환경농학회 학술대회집 Vol.2014 No.-

        Evaluation of the residual behavior of pesticides in agricultural products before and after the household processing effects is pivotal to protect consumers from negative health effects caused by residues. In this study, The effects of various household processing effects, including washing, boiling, frying, and blanching on the residual pattern of diethofencarb in crown daisy and procymidone in leeks were investigated. For diethofecarb, the original QuEChERS with slight modifications was used for extraction followed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) analysis; whereas, procymidone was extracted with acetone, purified with silica- solid phase cartridges, and analyzed using GC-ECD analysis. Recoveries at 3 different fortification levels were ranged between 73.7 - 100.0% with relative standard deviations (RSDs) <16%. The developed method was sensitive to estimate the residue levels below the maximum residue limits (MRLs) set by the Ministry of Food and Drug Safety.

      • 05 포스터 발표 : 환경 화학 분야(PC) ; LC-MS/MS를 이용한 현미와 볏짚에서의 Benzobicyclon과 대사체 잔류 분석

        임소정 ( So Jeong Im ),최정희 ( Jeong Heui Choi ),김성우 ( Sung Woo Kim ),정다이 ( Da I Jung ),이영준 ( Young Jun Lee ),무스픽 ( Musfiqur Rahman ),압두 ( Abd El Aty ),심재한 ( Jae Han Shim ) 한국환경농학회 2014 한국환경농학회 학술대회집 Vol.2014 No.-

        This study was carried out to develop an extraction as well as an analytical method for detecting benzobicyclon and its amino-substituted metabolite (1315P-570) in brown rice and rice straw using liquid chromatography-tandem mass spectrometry (LC/MS/MS) in positive ionmode with multiple reaction monitoring (MRM). The parent as well as the metabolite in rice and rice straw were extracted and analyzed under the same conditions. The matrix-matched calibrations showed good linearity with determination coefficients ( R2) of > 0.994. Recoveries at two different spiking levels were satisfactory and ranged between 75.4.118.9% with relative standard deviations (RSDs) < 13% for both analytes. Under storage conditions (.20℃), the analyte and its metabolite were stable for up to 92 days. The limits of quantitation (LOQs) were lower than the maximum residue level (MRL) set by the Ministry of Food and Drug Safety for brown rice (0.1 mg/kg). Field trials with recommended or double the recommended dose revealed that the herbicide could safely be applied to rice and rice straw, as no residues were detected in the harvested samples. The sensitivity of the developed method was sufficient to ensure reliable determination of benzobicyclon and its metabolite in rice grain and rice straw.

      • 05 포스터 발표 : 환경 화학 분야(PC) ; PC-03 ; LC/MS/MS를 이용한 현미와 볏짚 중 orthosulfamuron 잔류물 분석

        이영준 ( Young Jun Lee ),최정희 ( Jeong Heui Choi ),김성우 ( Sung Woo Kim ),정다이 ( Da I Jung ),임소정 ( So Jeong Im ),무스픽 ( Musfiqur Rahman ),압두 ( Abd El Aty ),심재한 ( Jae Han Shim ) 한국환경농학회 2014 한국환경농학회 학술대회집 Vol.2014 No.-

        Rice is one of the most consumed grain in the world because of its nutritional value. Orthosulfamuron, a selective and systemic herbicide, was used to control the post-emergence of annual and perennial broad leaves weeds, sedges, and barnyard grass in rice field. In this study, a modified QuEChERS method was used to extract orthosulfamuron residues from brown rice followed by tandem mass spectrometry. analysis in positive ion electrospray ionisation(ESI+). A determination coefficient ( R2) of > 0.994 was computed from matrix-matched calibration ranges of 0.01 to 2.0 mg/kg. Recoveries at two fortification levels (0.1 and 0.5 mg/kg) were acceptable (88.1 - 100.6%) with relative standard deviations (RSDs)<8%. The limit of quantitation (LOQ), 0.03 mg/kg, was comparatively low compared to the maximum residue limit (MRL = 0.05 mg/kg) set by the Ministry of Food and Drug Safety in the Republic of Korea. The method was successfully applied to field samples and none of the samples contain a residue higher than the limit of detection.

      • KCI등재

        ADHD학생의 문제행동 중재를 위한 단일대상연구의 전반적인 동향 분석과 CEC 질적 지표에 의한 분석 - 문제행동유형을 중심으로

        길한아 ( Kil Han-ah ),김미령 ( Jin Mei-ling ),마지성 ( Ma Ji-sung ),정다이 ( Jung Da-i ),( Sakura Yusuke ),손승현 ( Son Seung-hyun ) 대구대학교 한국특수교육문제연구소 2019 특수교육저널 : 이론과 실천 Vol.20 No.2

        본 연구는 ADHD 학생들의 문제행동 개선을 위한 행동중재 관련 단일대상 연구를 대상으로 일반적인 특성에 대해 문제행동 유형별로 분석하며, 이들 연구의 질적 수준을 확인함으로써 다양한 문제행동중재의 방안과 교육 현장에서의 시사점을 도출하고 질적 수준을 갖춘 단일대상연구가 되기 위해 어떤 노력이 필요한지에 대한 구체적인 개선 방안을 도출하고자 한다. 분석 결과 첫째,‘부주의(주의산만)’를 종속변인으로 한 논문은 총 18편이였으며, 다음으로는‘과잉행동’이 11편,‘충동성’이 9편,‘공격행동’이 8편,‘자리이탈’이 4편,‘방해 행동’이 3편,‘과제불이행’이 2편,‘소리내기’와‘울화’는 각각 1편으로 나타났다. 둘째, CEC 질적 지표의 8가지 영역인 맥락과 환경, 참여자, 중재자, 중재설명, 중재충실도, 내적타당도, 종속변인, 자료 분석을 분석한 결과 종속변인 영역과 자료 분석 영역이 96%로 가장 높은 충족률을 나타냈으며, 중재 충실도 영역은 가장 낮은 충족률을 보인 영역으로 13.3%의 충족률을 나타냈다. 분석결과를 근거로 하여 본 연구의 한계점과 ADHD 학생을 위한 문제행동 중재 관련 연구의 향후 과제에 대해 논의하였다. The purpose of this study was to examine the general characteristics of behavioral interventions for improving behavioral problems of ADHD students and to identify the level of quality of these behaviors, I would like to elaborate concrete improvement measures that need to be taken to draw implications and to make a single subject study with a qualitative level. The first analysis showed that there were a total of 18 papers with "Carelessness (distraction)" as a dependent variable, followed by 11 studies with "Hyperactivity" , 9 studies with "Impulsiveness", 8 studies with "Aggressive Behavior", 4 studies with "Out of seat", 3 studies with "Interrupting", 2 studies with "Noise" and 1 study with "Fuss". Second, we analyze the eight areas of CEC qualitative indicators : context and environment, participant, mediator, explanation of intervention, fidelity of implementation, internal validity, dependent variable and data analysis. As a result, the dependent variable area and data analysis area had the highest rate of 96%, and the fidelity of implementation area showed the lowest satisfaction rate, which was 13.3%. Based on the results of the analysis, the limitations of this study and the future tasks of the study on intervention problem behavior for ADHD students were discussed.