RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI우수등재

        폴리프로필렌/지르코니아 혼합물의 방사성에 관한 연구(I)-방사조건에 따른 구조와 기계적 성질-

        전재완,주창환,김동철,Jeon, Jae-Wan,Ju, Chang-Hwan,Kim, Dong-Cheol 한국섬유공학회 1994 한국섬유공학회지 Vol.31 No.5

        The zirconiunl dioxide(ZrO2) has characterized as a far infrared radiator and can apply as the thermal storage material by mixing with various polymers. In the present work, PP chips were blended with ZrO2 particles by the banbury mixer and spun PP/ZrO2 composite fibers by using the melt spinning machine with different spinning conditions. Effect of the draw ratio and amount of ZrO2 on the morphological structure and mechanical properties of the produced PP/ZrO2 composite fibers has been investigated. The results obtained are as follows: (1) the good dispensability of ZrO2 particles in the PP fiber has been observed and the phase separation between PP and ZrO2 has an increasing trend with increasing draw ratio on PP/ZrO2 composite fibers. (2) the breaking stress has increased to a significant extent with increasing the draw ratio, but decreased with increasing the amount of ZrO2, (3) in the X-ray diffraction pattern, the peak intensities of PP/ZrO2 composite fibers have increased with increasing the draw ratio, and (4) the crystallinity of PP/ZrO2 composite fibers has slightly changed with increasing the amount of ZrO2 and considerably increased with increasing the draw ratio.

      • 좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석

        전재완,박철우,홍종수,진성진,강정훈,Jeon, Jaewan,Park, Cheolwoo,Hong, Jongsu,Jin, Seongjin,Kang, Junghun 대한방사선치료학회 2017 대한방사선치료학회지 Vol.29 No.1

        목 적: 방사선치료의 가장 기본적인 조건은 정상조직의 불필요한 피폭을 방지하는 것이다. 유방암의 경우는 폐와 심장에 조사되는 선량이 중요하게 평가되는 인자이다. 따라서 유방암 방사선치료 자세에 따른 정상조직에 조사되는 선량을 비교하고 그 연관성을 상관관계 분석을 통하여 결과를 확인하여 보다 효과적인 유방암 방사선 치료방법을 모색하고자 한다. 대상 및 방법: 본원을 내원한 좌측 유방암 환자 30명을 대상으로 Supine, Prone Position에서 CT image를 획득하였다. Eclipse Treatment Planning System(Version 11, USA)을 이용하여 전산화치료계획을 수립하였다. DVH(Dose Volume Histogram)을 통해 Position 별로 정상조직에 조사된 선량을 비교하였다. 그 결과를 바탕으로 SPSS(Version 18)을 이용하여 각 정상조직의 선량인자를 통계분석하고 항목 간 상관관계 분석 및 독립표본 t-test를 통하여 그 연관성을 알아보았다. 그리고 MIRADA RTx(Version Advanced 1.6, UK)를 이용하여 HI(Homogeneity Index)와 CI(Conformity Index)를 Supine, Prone Position에서 값을 구하고 비교하였다. 결 과: 유방암의 전산화치료계획의 결과 폐의 경우는 Supine Position에서 V20은 $16.5{\pm}2.6%$, V30은 $13.8{\pm}2.2%$, Mean dose는 $779.1{\pm}135.9cGy$(Absolute value)를 보였다. Prone Position은 위 순서대로 $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$를 보였다. Prone Position이 전반적으로 낮은 선량을 나타내었고 평균선량 537.7 cGy가 더 적게 폐에 조사되었다. 심장의 경우에는 Supine, Prone 순서대로 V30은 $8.1{\pm}2.6%$, $5.1{\pm}2.5%$, Mean dose는 $594.9{\pm}225.3cGy$, $408{\pm}183.6cGy$를 보였다. Prone Position에서 평균선량 182.6 cGy가 더 적게 조사된다는 것을 확인하였다. 통계분석 결과 신뢰도 분석지표인 Cronbach's Alpha value는 0.563이였고 변수간의 상관관계분석 결과 치료자세와 폐의 선량평가인자는 대략 0.89 이상으로 그 상관관계가 높았다. 반면 심장의 경우는 V30은 0.488, Mean dose는 0.418로 상관관계가 다소 적었다. 마지막으로 독립표본 t-test 결과 치료자세와 폐, 심장의 선량평가인자가 신뢰수준 99 %에서 모두 유의하게 나타났다($p-value{\leq}0.05$). 결 론: 현재 방사선치료는 최첨단 선형가속기와 다양화된 전산화치료계획 기술이 개발되고 있다. 이 발전의 기본전제 조건은 PTV(Planning Target Volume) 주위의 정상조직 보호라고 생각한다. 물론 유방암 환자를 Prone Position에서 치료하면 Set-up의 재현성 문제와 다소 많은 시간이 소요되지만 이 실험결과에서 보듯이 Prone Position에서 폐와 심장에 들어가는 선량을 줄일 수 있으며 그 연관관계도 의미가 있다는 것을 확인하였다. 결론적으로 Prone Position에서 충분한 치료시간을 확보하고 정확한 치료부위 확인이 이루어진다면 환자에게 보다 좋은 방사선치료를 제공할 수 있다고 생각된다. Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

      • 저공해차 기술개발 현황

        전재완,Jeon, Jae-Wan 한국LP가스공업협회 2007 LP가스 Vol.19 No.5

        최근 온실가스규제가 강화되면서 저공해차에 대한 관심이 높아지고 있다. 국내외 저공해차 기술개발현황을 소개한다.

      • 에너지원별 가격 경쟁력 구조변화

        전재완,Jeon, Jae-Wan 한국LP가스공업협회 2005 LP가스 Vol.17 No.5

        지난 10월 20일부터 21일까지 제주에서 에너지관련 워크숍이 개최되었다. 워크숍에서 발표된 내용 중 산업연구원에서 발표한 "에너지원별 가격경쟁력 구조변화"를 소개한다.

      • KCI우수등재

        폴리프로필렌/지르코니아 혼합물의 방사성에 관한 연구(II)-방사조건에 따른 열적 및 점탄성 성질-

        전재완,주창환,김동철,Jeon, Jae-Wan,Ju, Chang-Hwan,Kim, Dong-Cheol 한국섬유공학회 1994 한국섬유공학회지 Vol.31 No.6

        In order to investigate the thermal and viscoelastic properties of Pp/ZrO2 composite fibers, polypropylene(PP) chips were mixed with the zirconium dioxide(ZrO2) powder characterized as a far infrared radiator and PP/ZrO2 composite fibers were spun by using the melt spinning machine with different spinning conditions (i. e.. draw ratio and the amount of ZrO2 Effects of spinning condition on the thermal and viscoelastic properties of the produced PP/ZrO2 composite fibers have investigated. The results obtained in this study are as follows: 1. The amount of ZrO2 on the composite fiber has scarecely influenced on the melting temperature and the melting temperature of iolo Pp/ZrO2 composite Hber is 161℃, but the crystallinity temperature has increased with increasing the amount of ZrO2 and the decomposition temperature of Pp/ZrO2 composite fiber has an decreasing trend with increasing the draw ratio. 2. The loss tangent(tan 6) has decreased with increasing the draw ratio in the ad absorption peak, but the absorption intensity of E' and E" has increased with increasing the draw ratio in the ac absorption temperature. Meanwhile, in the aa absorption region, the loss tangent of PP/ZrO2 composite fibers has decreased with increasing the amount of ZrO2.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼