임형찬(Hyung Chan Lim),김성일(Seong Il Kim),최영범(Young Bum Choi) 대한설비공학회 2019 대한설비공학회 학술발표대회논문집 Vol.2019 No.-
Our client company announced that it will supply photovoltaic modules totaling 1.5 GWp to the No. 2 power generation company in the U.S.A. The 1.5 GWp module supply contract is a single contract in the solar power industry. The contract was the largest ever at that time. If 1.5 GWp module might be installed, the city of Dae-gu, that has about 2.5 million people, can generate electricity that can be used by the entire population. The power generation company had planned to install all of the modules that provided from our client. Its own solar power plant is scheduled to be built in the U.S.A Therefore, it was decided that the existing production capacity could not satisfy the required supply, so it was newly promoted to construct a domestic factory.
○○해양과학관 Life Support System 중 열원시스템 개선 사례
홍성근(Sung-Keun Hong),임형찬(Hyung-Chan Lim),김성일(Seong-Il Kim),최영범(Young-Bum Choi) 대한설비공학회 2011 대한설비공학회 학술발표대회논문집 Vol.2011 No.7
The main goal of the LSS (Life Support System) of hot and cold water supply, that is from the distribution of various organisms ( Fish / Mammals / Oceanic plant ) that inhabit in the aquarium is to keep the exact water temperature with the best conditions. Therefore, to maintain the water tank's diverse organisms water temperature, there is a need for the safety of the hot and cold water supply in the facility system and there are related maintenance expenses that follow as well. In considering the specific 30 years must-be run BOT ( Build Operate Transfer ) project's characteristics, minimizing the maintenance expenses is more than necessary. In practice, reducing the expenses of the original turbo chiller and vacuum hot-water boiler were actually saved by using the air heat-source heat pump system.
김현대(Hyundae Kim),박재성(Jae-Sung Park),강승훈(Seung-Hoon),임형찬(Hyung-Chan Lim),이재곤(Jae-Gon Lee),백남춘(Nam-Choon Baek) 대한설비공학회 2012 대한설비공학회 학술발표대회논문집 Vol.2012 No.6
Zero energy solar house(ZeSH-II) is applied solar heating systems with geothermal heat pump as a auxiliary heating system, roof integrated PV module, it was analyzed and evaluated the integrated energy performance. According to the evaluation result, in 2010 energy consumption is recorded 5,735.35 kW, excluding the cooking load, but the ZeSH-II identified that the 94% of the average energy self-sufficiency could be achieved. The 85% of the energy self sufficiency rate of the total energy load, which is the second stage goal of this study, is expected to be achieved. And the energy self sufficiency rate of the total energy load in the first half of 2011 is incredibly similar to it in the first half of 2010.